5a 1
3 4
4. Remove spacer screw and fit torque coupling or 5b 6
Namur coupling onto coupling spacer. Separate 4a
6
spacer and indicator drum and rotate spacer to
align coupling with actuator shaft. Fit coupling
spacer over indicator drum drive hub.
4a. Secure torque coupling assembly or Namur Touch & Tune Switch Setting
coupling with screw of proper length. (Additional 8. Lift bottom cam and rotate until switch is activated. Release
coupling spacers and longer screw may be cam and be sure it slides fully onto spline.
required on some mountings.) 8a. Operate actuator to opposite position, push down on top cam
and repeat process.
5. Slide Thru-Bolts with washers into housing and fit
retaining quad-rings over bolts to retain them. (See Reverse Side for Wiring Diagram)
5a. Top of actuator shaft should be within 1/4"
(6.35mm) from coupling screw head or Namur
coupler. CAUTION:
5b. Torque coupler or Namur coupler must be fully
TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERES,
engaged in slot and be centered on the shaft or
REPLACE COVER BEFORE ENERGIZING THE ELECTRICAL
block attached to the shaft.
CIRCUITS.
6. Operate actuator to full open and full closed
positions and check for proper alignment between KEEP COVER TIGHTLY CLOSED WHEN IN OPERATION.
switch and actuator. Eccentricity of shaft must
be no greater than .01" (.254mm) from
centerline. The torque coupler or Namur coupler
must be centered on the flats of the actuator shaft
or block in both the full open and full closed
position. Realign as necessary and final tighten
Thru-Bolts. StoneL Corporation
One StoneL Dr
7. "Fine-tune" visual indicator cover repeating #2 and 26275 US Hwy 59
lightly tighten set screw. Fergus Falls, MN 56537
USA
Telephone: 218.739.5774
Toll Free: 800.843.7866
Fax: 218.739.5776
© 2001 StoneL Corporation E-mail: sales@stonel.com
Approval Agency Controlled Document.
No Changes Authorized Without Prior Agency Approval Website: www.stonel.com
Pub # 105076revA
QUARTZ with SPDT Mechanical Switches Page 2
Specifications: Quartz with SPDT mechanical switches Specifications: Quartz with SPDT mechanical switches
with silver contacts (QZM2V__, QZE2V__, QZM4V__, with gold contacts (QZM2W__, QZE2W__, QZM4W__,
QZE4V__, QZM6V__, QZE6V__). QZE4W__, QZM6W__, QZE6W__).
Electrical Ratings: 10.0 Amp @ 125/250 VAC Electrical Ratings: 1.0 Amp @ 125 VAC
0.5 Amp @ 125 VDC 0.5 Amp @ 30 VDC
Temp. Range: -40° to 80° C Temp. Range: -40° to 80° C
Operating Life: 400,000 Cycles Operating Life: 100,000 Cycles
Warranty: Two years Warranty: Two years
**Not recommended for electrical circuits operating at less than **Recommended for ues in 24 VDC computer input applications
20mA @ 24 VDC
Wiring Diagrams
2 SPDT Switches (QZM2V, QZM2W, QZE2V, QZE2W) 4 SPDT Switches (QZM4V, QZM4W, QZE4V, QZE4W)
NC C
NO TOP
SWITCH
NO NC
TOP
SWITCH C
C NO SECOND
SWITCH
NC
C C
NO THIRD
SWITCH
NO BOTTOM NC
SWITCH C
NC NO BOTTOM
SWITCH
NC
NC Spare
NO THIRD Spare
C SWITCH Spare
C NC
NO SECOND BOTTOM NO
SWITCH SWITCH C
NC
C NC
NO FIFTH NO
TOP
NC SWITCH SWITCH C
Spare C
Spare FOURTH NO
Spare SWITCH NC
StoneL Corporation Phone: (218) 739-5774 · Toll-free: (800) 843-7866 · Website: www.stonel.com