This 5-day training course teaches participants how to independently set up and parameterize a SICAM PAS system. The course combines lectures, demonstrations, and hands-on exercises to provide an overview of SICAM PAS components and teach configuration of interfaces for IEC 61850, IEC 60870-5-101/103/104, and HMI systems. Upon completion, participants will be able to configure devices, set up communications, define data volumes, and use tools like the Value Viewer and control functions.
Original Description:
Training
Original Title
SICAM PAS Trng SICAM PASParameterization Training12
This 5-day training course teaches participants how to independently set up and parameterize a SICAM PAS system. The course combines lectures, demonstrations, and hands-on exercises to provide an overview of SICAM PAS components and teach configuration of interfaces for IEC 61850, IEC 60870-5-101/103/104, and HMI systems. Upon completion, participants will be able to configure devices, set up communications, define data volumes, and use tools like the Value Viewer and control functions.
This 5-day training course teaches participants how to independently set up and parameterize a SICAM PAS system. The course combines lectures, demonstrations, and hands-on exercises to provide an overview of SICAM PAS components and teach configuration of interfaces for IEC 61850, IEC 60870-5-101/103/104, and HMI systems. Upon completion, participants will be able to configure devices, set up communications, define data volumes, and use tools like the Value Viewer and control functions.
This course is a combination of lecture, demo and hands-on exercises. The participants will be able to independently set up a SICAM PAS
General Information Topics
Course Code: SICPAS002 • Introduction Length: 5 Days • System components • PAS Software Setup Audience • New project with T101 master • The training is intended for customers from • PAS Operation power utilities and industry responsible for • Value Viewer operating a SICAM PAS system. • Normalization • T101 slave interfaces Prerequisites • Data test with IECTEST • SICAM PAS Basics • T104 interface • Data test with IECTEST Goals • Parameterization of a T103 interface via Se- Upon completion of this course, the students rial Hub 7XV5655 shall be able to: • Defining data volume of a device description • Provide an overview of SICAM PAS total sys- • Configuring an HMI interface tem • System variables • Install SICAM PAS software • Control Authority • Configure an IEC 870-5-103 interface • Remote WinCC • Use Device Descriptions (files) OPC • Use the SICAM Value Viewer • CFC-Logic Functions • Configure an IEC 870-5-101 interface • Introduction of ST Programming Language • Configure an IEC 870-5-104 interface • Introduction to IEC61850 • Setup a Server-DIP configuration • Creating a DIGIS database for a 7SJ63 • Access a Remote PAS CC • IEC61850 system configurator • Normalizing measured values • Data export and import • Configure a PAS CC interface • How to use Trace Function • Connect a IEC 61850 IED • Server DIP configuration (in theory only)
Relays Course Descriptions Siemens Energy Management & Automation Division