3A1 No steam or regulator fails
3A2 Heat exchanger blocked
3A3 Pneumatic circuit fails
3A4 Temp probe or controller fails
3A5 Water jacket holed
3A6 Pressure relief valve fails open
3A7 Water pump or control system fails
3A8 Over temperature valve fails
4) To meet PUWER 98
4A Check list
5) Inject steam into head space
5A NO steam supply
5A1 Pneumatic system fails
5A2 Steam isolated
5A3 Steam slam valve fails
6) To fill and cap a product that is
safe to the customer
6A Fail to detect broken jars
6B Fills jars at below 92.5c
6C Incorrect or non fitting cap
7) To detect product level in
filler bowl
7A Fail to maintain correct level
7A1 Probe or control fails
8) To be able to adjust bowl height
8A Bowl does not move
8A1 Motor/gearbox fails
8A2 Drive train fails
8A3 Control circuit fails
8B Bowl does not stop
8B1 Low or high level switch fails
9) To be able to CIP and rinse
9A Fail to CIP
9A1 No water supply
9A2 Pump fails
9A3 Pneumatic system fails
3
9A4 Water temp to low
9A5 No caustic dosing
9B Fail to rinse
9B1 No water supply
9B2 Pump fails
9B3 Pneumatic system fails
9B4 Water temp tow low
10) To be able to size change in
15 minutes
10A More than 15 minutes
10A1 Change parts not available
10A2 Gripper change over design
11) Safety 11A Safety checks 11A1 Cap hopper stop button fails
11A2 Cap hopper guard interlocks fail