Professional Documents
Culture Documents
1.beam Design For Fire Station Reisdential Building
1.beam Design For Fire Station Reisdential Building
1.beam Design For Fire Station Reisdential Building
Beam Design for Residential Quarter for Moshi Fire Station at Moshi
Given Data:
Assume Beam Size 230x600
=575mm
Mu =252.54 kN-m
110∗106
d=√
0.133𝑥230𝑥25
= 150 mm
Rebar calculation:-
d=575, b =230 mm
0.5𝑓𝑐𝑘 4.6𝑥𝑀𝑑
Ast = 1 − √1 − 𝑓𝑐𝑘.𝑏.𝑑.𝑑 bd
𝑓𝑦
0.5𝑥25 4.6𝑥110.0𝑥106
Ast = 1 − √1 − 25𝑥230𝑥575𝑥575 x230x575
500
0.85𝑥230𝑥575
Ast min = 500
=461.8 mm2
Shear Reinforcement:-
Refer analysis result
Vu =131.5 KN
𝑉𝑢
τv = ……………………………………..IS 456 : 2000. Cl40.1 Page 72
𝑏𝑑
131.5𝑥10^3
τV = 230𝑥575
τv = 0.99 N/mm2.
Provide stirrups.
8 mm φ stirrups
𝐴𝑠𝑣 .𝑓𝑦
Sv = ……………………………………..IS 456 : 2000. Cl 26.5.1.6 Page 48
0.4𝑏
𝜋
2𝑥 𝑥82 𝑥500
4
Sv = 0.4𝑥230
Sv = 0.75 d
Sv = 0.75x575
Sv =420mm.
Provide 8mm φ two legged stirrups @ 125 mm c/c at support and 150m c/c at mid-span
Vu = Vus + τc .b .d
= 0.87 x fy x Asv d
0.87x500x2x(𝜋⁄4)x82 x575
= 125
Vus = 201.162 KN
= 0.58x230x575
= 76.7 KN.