Replacement instructions solid cone CD-Pro draft 07/06/01

PHILIPS OPTICAL STORAGE

Replacement Instructions

Turntable Cone

CD-Pro 2

Preface
This document describes the handling instructions for replacement of the solid turntable cone in
the CD-Pro(2) products.

Philips Components

Philips components©2001 Philips Electronics All rights reserved 0124 W.L. Optical Storage Page 1
Replacement instructions solid cone CD-Pro draft 07/06/01

INSTRUCTIONS

1. PREPARATIONS

Important:
Follow the general handling instructions for CD-Pro(2)
Take appropriate measures against ESD

Tools:
Use a pair of small screwdrivers (2 mm blade width max)

Working position:
Place the unit in front of you as indicated in fig 1. – Do not touch the lens

!
Do not
touch the
lens

Turntable
cone Use a pair of small
screwdrivers
(blade width
2mm max)

Figure 1

Philips components©2001 Philips Electronics All rights reserved 0124 W.L. Optical Storage Page 2
Replacement instructions solid cone CD-Pro draft 07/06/01

2. REMOVING THE TURNTABLE CONE

See Fig. 2:
• Insert the screwdrivers into the small slots at either side of the turntable cone
• Carefully move the screwdriver handles upward simultaneously to lift-off the
cone.

Important:
Do NOT move screwdrivers downward to avoid turntable damage.

Insert screwdrivers into


slots and…

… move screwdriver
Figure 2a. handles
upward
simultaneously

Figure 2b.

Philips components©2001 Philips Electronics All rights reserved 0124 W.L. Optical Storage Page 3
Replacement instructions solid cone CD-Pro draft 07/06/01

!
Avoid turntable
damage -
DON’T
PUSH-DOWN
screwdrivers
to lift-off cone

Figure 3

3. MOUNTING TURNTABLE CONE

See Fig. 4
• Place the new turntable cone over the turntable shaft.
Do NOT apply any glue.
• Push cone down gently until it touches the turntable surface.

Important:
Do NOT exceed maximum force allowed to turntable.
Place new cone
and push down
gently

No spacing
between cone
and turntable

Figure 4

4. PROBLEM SOLVING

Symptom: CD slips during spinning-up or braking.


Cause: The disc is not clamped sufficiently.
Remedy: Push down the cone until it touches the turntable surface.

Symptom: CD-PRO(2) does not play correctly.


Cause: Turntable pushed down/max force to turntable exceeded.
Remedy: Replace CD-PRO(2) mechanism.

Philips components©2001 Philips Electronics All rights reserved 0124 W.L. Optical Storage Page 4