Operating Instructions: Single "
Operating Instructions: Single "
Operating Instructions: Single "
E-Mail: info@single-temp.de
Internet: http://www.single-temp.de
Seite 1 von 23
Chapter 1 ⇒ turning the unit ON
Key- functions description "Starting panel" Page 3
Seite 2 von 23
Main switch or plug = supply reset Selection key “Filling”
Please note: After supply reset, the displays • Manual or automatic filling,
show the date of the last if water is the medium
software alteration ON (button)
• system “working”; • If Oil is the medium,
pump and controls “active”; fill-up manually only! Special- functions key
potential-free contact on 8+9 • Interlocked through configuration • On heat-balancing units with interface
• actuate this key, if "external" start parameter "C4" () p.11) change-over to “Remote operation”
applies; flashing LED shows • With connection for “external controllers”,
OFF (key)
readiness for start via terminal change-over to “external control”
• All systems “OFF”; LED is alight, 27 + 28 • Interlocked through configuration “C7” () p.11)
for as long as voltage supply is
live • Must be acknowledged with “Quit” after
activation
Mould evacuating
• When actuated, this function evacuates water
from mould by “Cooling” change-over switch
a) compressed air • to “direct cooling”
b) pump
Heating (Switch) • confirm with “QUIT” on the inputting- and control panel
• time settable through parameter “A6” () p. 4)
• Turning heating ON and OFF • Interlocked via “C6” configuration () p. 11)
• followed by automatic pressure (stored safe from power-cut)
Water as medium
• Mould evacuation by compressed air Pump-lag control
(optional) • System cools down and turns OFF
• No function, when “system shut-down”active, • Acknowledge with "QUIT" in the inputting- and control
i.e. "Closed" LED on information panel is alight. panel cooling-down temperature selectable with "C5"
Oil as medium • Interlocked via "C5" configuration () p. 11)
• Evacuate external volume (optional)
• Reversing switch for pump
Seite 3 von 23
Switch (for accessing various levels)
• 1 x "P" = working level
Value-alteration key
• 1 x "P" + "QUIT" = parameter level; followed
Internal / external thermocouple change-over • For increasing set- and parameter-values
with another "P" = individual parameter
Selection: a) Push “Sensor” once = external probe Attention!
• 1 x "P" + "QUIT" held for about 4 s. =
(PT 100, NiCr-Ni, Fe-CuNi, selectable in the Confirm with “QUIT” !
configuration level; followed by another “P”
parameter record).
= individual parameters
If no external probe fitted, although the "external"
LED flashes, closed-loop control takes place
internally- "Intern" is alight.
b) Switching-over can also be carried out by an
external, potential-free contact (terminal 11+12
Value-alteration key
of corresponding configuration "C10") () p. 12)
• For reducing the set- and
parameters-values
Attention!
Confirm with “QUIT” !
Display (PROCESS)
• Display of inlet temperature's
actual-value
• Display of parameter
designation when operating
at working-, parameter-
and configuration- level.
Seite 4 von 23
Acknowledgment-/ canceling-key
All alterations σ and τ must be
acknowledged (confirmed) !
(Set-values and parameters)
Flashing yellow LEDs on preselection keys
must be confirmed: OFF, direct and F1.
Flashing LED in panel: acknowledgment
required!
Seite 5 von 23
Working level
Inputting of: Limit comparator Aquatimer
Parameter 2. Set-value Evacuation time
No. Inlet-temp. monitoring Pressure input (low+high)
Leak-stop function By depressing “P”, one enters the
2. Limit-comparator
Seite 6 von 23
Working level
A.12 = Pd.t
Input of integration time for the capacity display
Preset values: OFF, 1-500 min.
A.13 = Adr
Appliance address
Seite 7 von 23
Information panel
2. 6.
1. Display – Information
Display of parameter numbers 7.
3. 8.
2. Temperature-display 4.
3. Oil-cracking temperature 5.
4. Inlet temperature
5. Return temperature
1. 17.
6. Selection key temp. display
7. Selection key medium- information
8. Selection key unit information
9. Medium-information (optional)
18.
10. Flow-rate display
11. Inlet pressure
12. Actual heating or cooling capacity 19.
10.
20.
13. Unit information 11.
14. Unit serial number
15. Lamp-check switching 12. 21.
16. Operating hours counter
9. 22.
13.
Seite 8 von 23
Cause LED alight ( ● ) or flashing ( ✺ )● Wrong direction of rotation Rectification / explanation
⇒ Swap phases on plug
✺ Two-phasing
⇒ Check direction of rotation
✺ Motor protection switch responded ⇒ Check phases (possibly supply-fuses)
⇒ Check and/or push motor protection switch
● Minimum level not made
a.) Water: ⇒ refill at ●
✺ Filling “active” ⇒ open supply valve, ●
("Filling" solenoid valve open) if filling process runs (LED flashes) ✺
b.) Oil: ⇒ fil or replenish with oil
✺ Expansion vessel overfilled Only for units with heat-transfer oil as medium!
⇒ Unit overfilled with oil
⇒ External volume too large
Attention ! Cancel with "QUIT"
⇒ Drain-off oil
✺ Limit comparator outside band-spread
limiting value exceeded ⇒ Not up to temperature, or outside band-spread (limit)
⇒ Band-spread too narrow or limiting value reached
⇒ Turn OFF with “P” up to (A.2) (1. Param. at working level) + ▼ till “OFF”, confirm with “QUIT”
✺ Return-temperature up to limiting value ⇒ Check set limiting value
⇒ possibly too low a flow rate
⇒ turn OFF via (P.16) + ▼ till “OFF”, confirm with “QUIT”
● Safety temperature restrictor – additional component ⇒ With oil units: oil up to limiting value; safety temperature restrictor active
in control cabinet has responded
⇒ Improve heat transmission, i.e. ensure adequate flow around heating rod,
✺ Up to oil-cracking temperature (safety alert) clean dirt-trap, install bypass, if necessary
Heating switches OFF ⇒ maximum temperature limiting-value for heating reached
Can only be canceled with "QUIT"! Check the flow (too little heat absorbtion from heater)
Seite 9 von 23
Designation „PROCESS“ Panel
Heating prefix +
P.1 Y % present regulation ration Cooling prefix -
Seite 10 von 23
Designation „PROCESS“ panel
„SET“ panel
Parameter
No.
Value
P.19 dt Delta-T-monitoring / delimitation Monitoring: OFF - 1...20
inlet-/ return-temperature Boundary: exceeding 20
up to 1•. ...20• (2. Group)
Monitoring: ASF alight;
alarm on change-over 85/86/87
Delimitation: ASF alight;
Variable is beeing turned OFF
Seite 11 von 23
„PROCESS“ panel
Designation
Parameter
No. Configuration level
C.1 LOC Keyboard interlock
OFF ⇒ No interlock
PC ⇒ Parameter- and configuration-level only are interlocked; i.e. the parameters can be locked at,
but not adjusted; automatic optimization is blocked
SP.t ⇒ The set-value only can be altered and all functions-keys are enabled as well, exept for those,
blocked by the configuration level
o.SP ⇒ Set-point only,meaning that all keys are blocked, with the exeption of the set-point, that can
be altered, or the sytem can be turned ON and OFF
ALL ⇒ Complete keyboard interlocking, switching ON or OFF possible only, not even set-point
alterations can be carried out
ATTENTION: When altering "LOC" paramters, "QUIT" must be depressed, until the
illuminated ring circulates a second time (approximately 5s).
Seite 12 von 23
Designation
Parameter
No.
Configuration level
C.3 SEt Interlocking of the SET-key
At operator communication-level the "SET"-key is blocked by this parameter, so as to
prevent the 2. Set-point gets activated impermissibly, or that the system gets switched to an
external set-point
ON ⇒ SET-key enabling
LOC ⇒ SET-key blocked
Seite 13 von 23
Designation
Parameter
No.
Configuration level
C.9 Ph Rotary field identification, phase-testing
Rotary field identification or phase failure recognition can be activated or turned OFF
with this parameter record
Seite 14 von 23
Designation
„PROCESS“ panel
Parameter
No.
Configuration level
C.13 c.1 Configuration “heating” output port
rEL ⇒ relay - output
biS⇒ bistabile output-port (0/18Vdc) for SSR
A.0 ⇒ Steady output-port 0-20 mA
A.4 ⇒ Steady output-port 4-20 mA
Configuration level
Seite 15 von 23
Designation „PROCESS“ panel Value
Parameter
No. Configuration level
C.16 out Selection actual-value output: 0: 0...20mA, 0...10V
4: 4...20mA
C.19 C.oS Calibration outsignal Start from -30°C to C.oE minus 80K
= Calibration of the measuring range i.e. minimum difference to the end
for analog signal (Actual + Set) of the measuring range
C.oS is the start of measuring range
Seite 16 von 23
„PROCESS“ panel Value
Parameter
No.
Configuration level
Designation
Seite 17 von 23
Configuration level
Designation
„PROCESS“ panel Value
Parameter
No.
Seite 18 von 23
Configuration level
Designation
„PROCESS“ panel Value
Parameter
No.
C.37 OF6
Duty cycle offset info for system output cooling. Setting range: 0 – 100 %
Use of the parameter:
To equalize unsteadiness of a cooling
valve, an offset (OFF-Set) can be entered
here in %.
P.Fi
C.38 Filter for stabilization of the actual-value display Setting range:
OFF; 1.0 – 60.0 seconds
Configuration level
Seite 19 von 23
Designation
Parameter
No. Configuration level
Pro
OFF
A: ARBURG
C.39 Protocol (interface) b: Boy
Selection of varius interface protocols E: ENGEL
St: SINGLE (standard)
Pb: Profibus (Gateway)
Pbd (internal Profibus)
CAN: CAN-interface
b 1-255
For OFF_0,3/0,6/1,2/2,4/4,8/9,6/19,2
C.40 Baudrate, transmission speed
dn1 7E1/7o1/7E2/7o2/7n2/8E1/8o1/8n1/8n2
C.41 Transmission format
dn2 0...999
C.42 Heat-balancing unit number 1. part
PS1 0...999
C.43 Heat-balancing unit number 2. part via secret code
C.44 Save or reactive control parameter records
Configuration level
Seite 20 von 23
Configuration level
Designation
„PROCESS“ panel Value
Parameter
No.
C.41 PS1 Save or reactive control parameter records via secret code
AIDS
Reactivation: The configuration set in our factory is reactivated – i.e.
all settings will be deleted and the factory is
reactivated. Proceed as follows: keep the „QUIT“
button depressed for about 10s, until SES is shown in
ATTENTION:
the display panel
This list serves for Configuration level
information purposes only.
Connection: For group fault-alarm, limit comparator or actual-value
Please take note of the simultaneous actuation of these two keys for more than 5s
and other in- and outputs refer to the enclosed
parameter list, regarding accesses the configuration level
diagram! () S. 18/19)
the configuration set and
Error 8: In the display? – delete via “QUIT” or supply-reset, i.e.
secured in our factory. Alteration is possible only, when “LOC” (C.1)
turn the main switch OFF and then ON again
(part of the ATTENTION: is in “OFF” postion!
Attention: When replacing an SES, transfer the configuration to
documentation).
the new unit (to be input manually)
Seite 21 von 23
Auxiliary Supply
L1/230VAC 97
L1/115VAC 96 115 VAC, only possible following modification
Power supply
N/MP 95
Power supply
94 Terminal / at side
N/MP 93
rotation- L3 92
and phase failure
identification L2 91
L1 90
30 31 32 33 34 35 36 37 38 39 40 41 42 43 45 46 47 48 49 50 51 52 53 54 55 56
+ -
Brücke Bridge
+ - + - + - + -
Fe-CuNi PT100 PT100 PT100 0..10 0..1 0/4...20mA
NiCr-Ni VDC kΩ 0/4-20mA Frequ. 0-10VDC (bridged 55/56)
or
0/4-20mA
Load 5 Ω + 0-10VDC - + - Bridge
PT100 PT100
Zone 1 Zone 2.1 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10
Controller Controller Return Inlet Oil-cracking Pressure Level- Set-value- Flow-meter Actual-value
„internal“ „external“ temperature restrictor temperature trans- status input (FM) output
duser
Seite 22 von 23
OUT1 OUT2 OUT3 OUT4 OUT5
heating cooling F2 Set / actual Pump
OUT6 OUT7 OUT8 OUT9 OUT10 OUT13
and controller „ON“
Water: Group- System- System Alarms Alarm
pressure 1„Limit“
system fault: shut off emptying active during: for
release + + limit monitor.
filling oil-crack. + limiting value- special-
venting + OK-zone
flow, Ati, Leakstop returnline; software
phase, empty min. volume;
oil: max. ∆Τ-Inlet-, returnline;
--- Outputs --- pressure, min /max.;
60 61 62 63 64 65 66 67 68 69 70 71 (terminals strip down) 2. Limit Soll/Ist
75 76 77 78 79 80 81 82 83 84 85 86 87 88
in out in out
alternative assignment,
Unlocking S1 active ext. probe external external
selectable via
STB F1 depr. “active” keyboard set-value
configuration level:
n/c contact n/o contact Interlock input
“LOC” “active”
Seite 23 von 23