OTDR Report Fail

General Information
Filename: Fiber39.trc
Test date: 12/7/2018 Customer:
Test time: 1:41:05 PM Company:
Cable ID: Fiber ID: Fiber39
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model MAX-710B-M1-EA
Serial number 810502
Calibration date 1/7/2015 (UTC)

Results
Span length: 0.0993 km Average loss: 11.459 dB/km Injection level: 16.1 dB
Span loss: 1.138 dB Average splice loss: 0.342 dB
Span ORL: 16.55 dB Maximum splice loss: 0.342 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 36.301 dB/km A-B average loss: 71.794 dB/km
a 0.0600 14.771 A-B LSA loss: 0.042 dB 4-point Event Loss: 8.775 dB
A 0.1200 11.266 A-B ORL: 60.18 dB Maximum reflectance: ---
B 0.1800 6.961
b 0.2210 2.170

Signature: _______________________________ Date: 12/7/2018 Page 1 of 2


OTDR Report Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -24.1 0.000
Section 0.0176 0.012 0.700 0.012
Reflective 2 0.0176 0.732 -60.7 0.744
Section 0.0125 0.003 0.250 0.747
Non-Reflective 3 0.0301 0.342 1.090
Section 0.0692 0.048 0.700 1.138
Reflective 4 0.0993 --- -33.0 1.138
Section 0.0180 --- --- ---
Echo 0.1173 --- -57.0 ---

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1310 nm
Splice loss (dB) 0.100
Connector loss (dB) 0.350

Test Parameters
A→B
Wavelength (nm) 1310 (9 μm)
Range (km) 0.3000
Pulse (ns) 50
Duration (s) 10

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 2.000000
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 12/7/2018 Page 2 of 2