Download as pdf
Download as pdf
You are on page 1of 17
University of Baghdad Time: 3 hours College of Engineering Date: June, 12, 2013 Civil Engineering Department First Attempt ‘Answer 5 Questions Only Instructors: Dr. Abbas A. & Qusay A. SELECTED TOPICS Qi) For the simply supported reinforced concrete girder-deck bridge shown in fig., having the following data Clearspan:15m {= 25 MPa [Span C/C: 16 m 400 MPa Truck: MS 18 Asphalt wt. = 1.5 kN/m? handrail wt. = 1.2 kN/m , Find: a-Slab total moment. Te net ae seen es aa geen i be Shear reinforcement at the critical section of an exterior Bridge cross-section (all Dimensions in mm) girder (use 216 bars).(Let d = h - 150) 'Q2) For the simply supported one-way concrete slab bridge having the following data: Clear span:7m Truck: MS 18 asphalt wt. = 1 kN/m? Span C/C:7.5m Slab thickness: 400mm edge beam total depth = 600 mm Edge beam width = S00 mm handrail wt. = 1.kN/m? Find: 2- Slab total moment. b- Edge beam total moment. 'Q3) For the beams on elastic foundation shown in figs., a Choose a suitable coordinate system, b- State the complementary solution. - Find the particular solution . d- State the boundary conditions needed age 2 +06 — (Do not solve state only) cau }Q4) For the circular reinforced concrete tank having the following data: Bm C (shrinkage strain) =300x10* f, (flexural) = 150 MPa base : hinge D (inside) =32m _ t (wall thickness) = 0.5m (to be check) f= 25 MPa top : free Yw=10kN/m? (hoop) a Hoop reinforcement at the critical section ( use @ 25 bars) b- Flexural reinforcement at the critical section ( use @ 16 bars) f, (concrete) = 2.5 MPa Q5) For the rectangular concrete tank having the following data: 6m. b= 3m Yw=10 KN/m? 5 MPa f,=150MPa _t=500 mm (to be check) a Vertical reinforcement at the critical section of long wall (use 216 bars), b- Horizontal reinforcement at critical section in the inner face (use 216 bars). Q6) In which case: 4 -Distribution reinforcement used in the conerete deck (slab) of bridges? b-Beam on elastic foundation analysis ? c-Water stop used in water tanks made of reinforced concrete ? ‘Gutiee Job Num | Date | By | Ck [Tite | araPrneontsterk Mg 18-44 L2t [1.83 0.6) bridges : 133 ab—-e88 officals stan 1524 2 eels won Venf L traffe B.28842 Mp. fe where oem ds? 350 MPa | As. ted : sj nz Bs. Ege 2ec seo MPA . etd EE = ArB0fR" Re Rie Te section Oe erste re fs_ Bah : “ Ve = 0-68 [fZ bud a Pe Boreal lose Gcwine Fick cooy AUB, 3A y-ve be WBS Number | Page Number | Sheet of Jo nber ] BoA ATTN 42F-3.16 act hs C Snax. = 4-56) Table Asa fing tension Fin cizeular tanks under triangular load. Fixed base, free top st f fom coott xwehir FE i | Postve sign indicates tnsion EA a | | 2 a : yy | g a | | a = Costin apn fom top EL) as en Pen oer | peariore as oe | vase | so1se | soa | soso | saom | veos | sao@ | oom | coow | sence oa | soz | Yozzo | tex | toro | cates | 2%0 | 2208 | sae | seer | so00e 12 | doam | togn.| soz |- tease | Soam | totes | tates | 893 | 04% | toot 1s | seats | tose | soz | toaes | Taz | tose |

You might also like