"CM"

PROJECT NAME :-

*NOTE: WE ARE ONLY RESPONSIBLE FOR SOUNDNESS OF STRUCTURE


REFLECTED THROUGH THE DRAWING ONLY & NOT FOR EXECUTION
SCHEDULE OF BEAMS AT PLINTH SLAB LEVEL CONCRETE GRADE M20 & STEEL GRADE Fe500 SCHEDULE OF BEAMS AT PLINTH SLAB LEVEL CONCRETE GRADE M20 & STEEL GRADE Fe500
THESE GENERAL NOTES APPLY TO ALL DRAWINGS. THE APPLY TO ALL RELEVANT PORTIONS
BOTTOM TOP BOTTOM TOP
SIZE STIRRUPS SIZE STIRRUPS OF THE STRUCTURAL STANDARD PROVISIONS SPECIFIED HERE UNDER SHALL WORKS &
REINFORCEMENT REINFORCEMENT REINFORCEMENT REINFORCEMENT
BEAM BEAM WORKS & SHALL FORM PART OF THIS CONTRACT.
NUMBER EXTRA TOP AT LEVEL REMARKS NUMBER EXTRA TOP AT LEVEL REMARKS
BOTTOM BOTTOM TOP SUPPORT BAR BOTTOM BOTTOM TOP SUPPORT BAR GENERAL NOTES :-
B D LEFT MIDSPAN RIGHT B D LEFT MIDSPAN RIGHT
FULL CURTAIL FULL DIA. FULL CURTAIL FULL DIA.
LEFT RIGHT LEFT RIGHT 1) THIS DRAWING SHALL BE READ ALONG WITH ARCH DRAWING,THE CONTRACTOR SHALL VERIFY
ALL DIMENSIONS & LEVELS ON SITE & RESOLVE ALL DISCREPANCIES WITH ARCHITECT OR
AT MID LANDING LVL. AT MID LANDING LVL.
ENGINEER PRIOR TO COMMENCEMENT OF WORK. DRAWING INDICATES GENERAL & TYPICAL
DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE OF SIMILAR CHARACTER TO DETAILS
SHOWN & ALTHOUGH NOT SPECIFICALLY INDICATED, SIMILAR DETAILS OF CONSTRUCTION
SHALL BE USED & SUBJECTED TO REVIEW BY THE ENGINEER.
2) MATERIAL GRADE M20 & Fe500 SHALL BE USED.(UNLESS SPECIFIED)

3) NOMINAL COVERS FOR MILD CONDITION


I) FOOTINGS : 50 MM , III) SLABS : 20 MM , V) LIFT WALL/SHEAR WALL : 40 MM ,
II) COLUMNS : 40 MM , IV) BEAMS : 25 MM

4) IN CASE OF SLAB IF MAIN REINF, DIAMETER EXCEEDS 12MM THEN COVER FOR
MODERATE AND SEVERE EXPOSURE CONDITION SHOULD BE INCREASED BY 5MM.

5) MAXIMUM ALLOWABLE HE GHT OF COLUMN W THOUT ANY BRACER OR T E


1) 230 WIDE-4000MM. 2) 200 WIDE-3400MM. 3) 300 WIDE-5000MM.

6) LAP LENGTH Note:-


M20 M25
COLUMNS
SLABS & BEAMS
52XD
60XD
46XD
50XD
} At any section of slab/beam not more than
50% bars to be lapped & laps should be
staggered.

7) NO SPLICES SHALL BE MADE AT POINTS OF MAXIMUM STRESS. E.G.,TOP BARS IN BEAMS


& SLABS SHOULD BE SPLICED AT MID SPAN AND BOTTOM BARS AT SUPPORTS. SPLICES
SHALL BE STAGGERED WHEREVER POSSIBLE.

8) TOP BARS OF CANTILEVER BAR SHALL NOT HAVE ANY LAP.

9) ALL STRUCTURAL CONCRETE SHOULD BE WEIGH BATCHED, MACHINE MIXED&MECHANICALLY


VIBRATED

10) FOR CANTILEVERS, TOP BARS TO BE ANCHORED BEHIND FOR-70XDIA. OF BARS OR SPAN
OF CANTILEVERS (WHICHEVER IS GREATER)

11) MOVEMENT CRACKS


ALL VISIBLE CRACKS IN NEWLY CAST CONCRETE SHALL BE SEALED BY PRESSURE GROUTING
BEFORE APPLICATION OF FINISHES.

DESIGN FOR :- ( B + P + 14 )
*LOADS *REFERENCE

BEARING CAPACITY --- KN/SQMT IS 456-2000 R.C.C.

LIVE LOAD 2.00 KN/SQMT IS 13920-1993 Ductility

FLOOR FINISH 1.00 KN/SQMT IS 800 Steel structures


BRICK DENSITY IS 3370 Liquid retaining structure
BRUNT BRICK 18.00 KN/CUB.MT
Criteria for earthquake
LOW WEIGHT BRICK 06.00 KN/CUB.MT IS 1893-2002
resistance design

STATUS OF RELEASE
FOR APPROVAL
FOR DISCUSSION
FOR TENDER
FOR CONSTRUCTION ARCHIECT DRAWING DATED --------

REVISIONS - DELT. BY CHK. BY APR. BY DATE


1 REV. AS PER ARCH. REQ. DATE 25-07-2017 BRIJESH VIVEK B.P.B. 26-Jul-17
2 REV. AS PER ARCH. REQ. DATE 27-07-2017 BRIJESH VIVEK B.P.B. 27-Jul-17
3 REV. AS PER ARCH. DRAWING DATE 28-07-2017 BRIJESH VIVEK B.P.B. 28-Jul-17
4 REV. AS PER ARCH. DRAWING DATE 10-08-2017 BRIJESH VIVEK B.P.B. 10-Aug-17
DRAWING TITLE :- BY DATE
DRAG. BRIJESH P. 31-May-17
* STRUCTURAL DETAILS DSG. VIVEK S. 31-May-17
OF PLINTH SLAB LVL. QC. SAHARSH 31-May-17
APPR. B.P.B. 31-May-17

PROJECT :- BALAJI VISHWA, ( C -BUILDING)


PROPOSED CONSTRUCTION OF RESIDENTIAL BUILDING
AT MOSHI.

CLIENT :-
DWG NO. SHEET NO.
IDEAL DEVELOPERS

ARCHITECT :- 2016/505 ST- 03


Ar. DEEPAK CHAVAN -1-

DELTACOM STRUCTURAL
CONSULTANTS

NASHIK OFFICE PUNE OFFICE


AT MID LANDING LVL. " Avdhoot Adhar ", 2nd floor' 7, Dattaprasad, 3rd floor,
Opp. Hotel Vihar, Old Gangapur Naka, 1206, B17, off. J. M. Road,
Nasik - 422005 Pune - 411004
Tel - 0253-2314995, 2571096 Tel - 83800 21794