Compressor Cutoff Controller
Compressor Cutoff Controller
SZ 7510E / SZ 7569E
CONTR
ROLLER
WITH 10/2
W 20A
RERLLAY
Coolin
ng output.
Main Fea
atures Memo
ory retention, tim
me delay for compressor protection.
Auto operation
o incase
e of sensor erro
or.
Temp erature
e range - 50°C to +50°C..
230VA
AC Standard. Otther models witth 12VDC, 24VD
DC, 110VAC on request.
General Specification
Panel cutout : 29 X 71 erminals : Admitt 1X 2.5 mm2 wire.
7 mm Screw te w
Spade
e terminals for compressors.
c (F
For SZ-7569-E only).
o
OPERATING INSTRUCTIONS
SZ-7510/69-E
General Description To fix the unit, slide the fastener 1 through the guides 2 as per the position shown in
the figure. Move the fastener in the direction of the arrow, pressing tab 3 it permits to
The SZ-7510-E/7569-E are aesthetically superior version of their move the fastener in the opposite direction of the arrow. Once the controller has been
connected, they should be covered with the lid 4 . Silicon sealant should be applied
predecessors. The SZ-7510-E/7569-E are single set point controllers. along the perimeter of the panel cut out or a rubber ‘O’ ring supplied before the unit is
fitted to increase protection against water seepage.
SZ-7569-E has an inbuilt power relay which can drive compressor Controller: Controller should be installed in a place protected by vibration, water and
loads directly upto 20Amps, thereby eliminates use of conductor in corrosive gasses and where ambient temperature does not exceed the values specified
in the technical data.
single phase applications. They are specifically designed for Probe: To give a correct reading, the probe must be installed in a place protected from
refrigeration applications wherein the compressor cuts off at set point thermal influences, which may affect the temperature to be controlled.
and is restarted at a temperature of set point plus differential. .
Operating Messages And Icon Status
Additionally the SZ-7510-E/7569-E offer several protection features
that are easily understood by the examples in the instructions below.
Message Mode Description Parameter
A number of parameters are displayed alphanumerically to set up the
instruments for each specific application. Flashing Probe short circuit, circuit open or without probe,
0 0
or temperature >50C or <-40C.
ON/OFF Comp. Relay on/off. SP, P4
The SZ-7510-E / 7569-E can be used for several application with a
measuring range from -40c0 to 50c.0 Flashing Time delay in progress. P6
ON/OFF Keypad locked/unlocked. LP
Data storage Non-volatile EEPROM memory. 1. Press & hold the prg key for 2 seconds.
Power input 230Vac +/-10%,50-60Hz. Others on request. prg 2. Display will show “P4“ & flash.
O O
Operating temp. 5C to 50C(non-condensing). 3. To go to other parameters, use or prg keys.
O O
Storage temp -20C to 70C(non-condensing).
Input NTC Probe, SZ-N75.
3. P4 Parameter : To set the differential.
Min Max Fac.
Range -40O C to 50O C
O O O O
Resolution 1C 1. To change the P4 parameter, press the “SET” key. 1C 20C 2C
Accuracy +/- 1CO 2. To go to desired value, use or keys.
3. To set desired value press “SET” key you will see
Probe tolerance +/- 0.3O C at 25O C “- - -” which confirms that the value has been stored
in memory.
This parameter is used to protect the compressor from 0Min 20Min 0Min
restarting in a short period of time and can be set
between 0 to 20 minutes. 3 5
Wiring Diagram
SZ-7510-E