Professional Documents
Culture Documents
Design of Bridge On Khadi On Surat-Valak Rad: 6.0 Forces and Moments Due To Wind Force
Design of Bridge On Khadi On Surat-Valak Rad: 6.0 Forces and Moments Due To Wind Force
DESIGNED
TITLE: MINOR BRIDGE DESIGN OF ABUTMENT AND ABUTMENT FOUNDATION
0
Left Span
C/C distance between Exp. Jt. = 30.000 m
Dist. between C/L's of Brg. & Exp. Jt. = 0.500 m
C/C distance between Bearing = 29.000 m
6.0.1 Wind Force on exposed area of the superstructure (Normal to the wind dir)
Page # 1
DOCUMENT NO
PROJECT: Design of Bridge on Khadi on Surat-Valak Rad
Abutment
DESIGNED
TITLE: MINOR BRIDGE DESIGN OF ABUTMENT AND ABUTMENT FOUNDATION
0
=
Page # 2
DOCUMENT NO
PROJECT: Design of Bridge on Khadi on Surat-Valak Rad
Abutment
DESIGNED
TITLE: MINOR BRIDGE DESIGN OF ABUTMENT AND ABUTMENT FOUNDATION
0
Page # 3
Multi Media Consultant Pvt. Ltd.
Abutment 12/12/2014
Sin q Tan q
0.000 0.000
DL LL
G= 2 2
CD = 1.1 1.2
= 187.5 m^2
= 158145 N/m^2
Page # 4
Multi Media Consultant Pvt. Ltd.
Abutment 12/12/2014
Page # 5
Multi Media Consultant Pvt. Ltd.
Abutment 12/12/2014
RA 158.15
10.54
Page # 6