607A-PI-001 FQI HS A I-100


NOTES:
001 001 100 I-179
DRAWING NO.
FAH-
FIC 1. LEGENDS AND ABBREVIATIONS REFER TO DWG.
001
600A-PI-001, 600A-PI-002 AND 600A-PI-003.
FAL- EV
001
2. CONTROL VALVES TO BE LOCATED AT PLATFORM
S ADJACENT TO AND ABOVE TOP OF PRENEUTRALIZER
A FE FIT
AI
FY 607AAMO1 (FREE DRAINING). A
001 001 001 FV 3. ALL SLURRY, PHOSPHORIC ACID AND SCRUBBER LIQUOR
WEAK PHOSPHORIC ACID 001 WEAK PHOSPHORIC ACID PIPING TO BE FLANGED AT FITTINGS AND AT 6M MAX.
SLOPE SLOPE
5026 80x50 80x50 5038 INTERVALS.
80 - PB - 607A - 001 - BD2 V-102-50 V-102-50 80 - PB - 607A - 001 - BD2
607A-PI-040 M 607A-PI-002 4. TOTALIZE FQI-004 AND FQI-637 TOGETHER IN DCS

V-102-25

V-102-25
NO POCKETS NOTE 3 FC NO POCKETS FOR TOTAL SULFURIC ACID USAGE.
MAG
FROM STORAGE NOTE 2 TO 607AAM01 5. INSTRUMENT TAG NUMBERS AND INTERLOCKS SHALL BE
PREFIXED BY THE UNIT AND UNIT SUBDIVISION (I.E. 607A)
HC HC
UNLESS SPECIFIED OTHERWISE.
03 03
V-102-50 HS A I-100 6. PSV INLET RATING: 300# & OUTLET RATING 150#.
FAH- 002 101 I-179
FIC EV
002 002
FAL-
S
FY INSTRUMENT NUMBERING
AI
FIT 002 FV LOOP NUMBERS RESERVED FOR THIS P&ID: 001-020.
B FE 002 002 LOOP NUMBERS NOT USED: 011-020. B
SCRUBBER LIQUOR 002 SCRUBBER LIQUOR
SLOPE SLOPE
5046 150 - LL - 607A - 029 - BG1 - PP V-109-150 V-109-100 150x100 V-109-150 150 - LL - 607A - 029 - BG1 - PP 5039 SPECIAL NOTE
607A-PI-026 M 607A-PI-002
NO POCKETS

V-108-25

V-108-25

V-108-25
NO POCKETS NOTE 3 150x100 MAG FC THIS DRAWING IS COPIED FROM DRAWING NO. 607A-PI-001
FROM 607AAD01 NOTE 2 TO 607AAM01 REV.04 CORRESPONDING PART OF SITE P1.

HC HC HC HS A I-100
06 06 V-109-100 06 003 102 I-179
FAH-
FIC
003 EV
FAL-
003
S
FIT FY
AI
FE 003 003 FV
C STRONG PHOSPHORIC ACID L.P. SLOPE 003 003 SLOPE STRONG PHOSPHORIC ACID LP.
C
5047 100 - PA - 607A - 001 - BD2 V-103-80 V-103-80 100x80 100 - PA - 607A - 001 - BD2 5040
607A-PI-040 M 607A-PI-002
NO POCKETS

V-102-25

V-102-25
NO POCKETS NOTE 3 100x80 MAG FC
FROM STORAGE NOTE 2 TO 607AAM01

HC HC
06-A 06-A
V-103-80

NOTE 4 FQI HS A
I-100
004 004 103
I-101
I-179
FAH-
FIC
004 EV
D FAL-
004
D
S
FE FIT FY FV
AI
004 004 004 004

98% SULFURIC ACID 98% SULFURIC ACID

11/8/2013 11:48:56 AM
5048 50 - SA - 607A - 001 - BD2 V-102-50 50x40 50x40 V-102-50 50x25 50x25 V-102-50 50 - SA - 607A - 001 - BD2 5041
607A-PI-040 M 607A-PI-002
NO POCKETS

V-102-25

V-102-25

V-102-25

V-102-25
NO POCKETS FC
MAG

CSC

CSC

CSC
CSC
FROM STORAGE FQI NOTE 2 TO 607AAM01
007

FIC
FAH-
HS A I-175 V-102-50
007 007 104
I-176
FAL- I-179 CSC 98% SULFURIC ACID DRAINS

\ODI-P2\607A\607API001.pid
25 - SA - 607A - 003 - BD2 25 - SA - 607A - 003 - BD2 5042
607A-PI-002
FIT EV NO POCKETS
007 007
E S
NOTE 2 TO 607AAM01 OVERFLOW E
FY
V-501-20

V-501-20

AI
007 FV
007 AMMONIA VAPOR
V-706-50 50 - AG - 607A - 025 - CB1 - PP V-706-50 50x40 50x40 V-706-50 50 - AG - 607A - 025 - CB1 - PP 5052
607A-PI-002

V-706-25
FC

V-706-25
FE
BB1 CB1
TO 607AAM01 DUCT

PID File Path:


007 CSC CSC

TI V-510-40
005 FQI
008
25 - AG - 607A - 049 - BB1 - PP
FAH-
FIC SET @ NO POCKETS
008 12.7 kg/cm2g
TIT PI FAL-
I-100 BD2 BB1
F 005 006 HS A
I-101
PSV AMMONIA VENT F
008 105 009 300 - AG - 607A - 036 - BB1 - PP 5053
I-179 607A-PI-015
FIT NOTE 6 300x250
008
EV NOTE 2
PIT 008 TO VENT STACK
006
S 200x150
TE FY FV
V-501-20
V-501-20

005
AI
008 008
CB1 BD2
TW
V-706-25

AMMONIA VAPOR 005 AMMONIA VAPOR


5049 V-706-300 300x250 300x250 V-706-300 V-614-300 V-104-300 5044
300 - AG - 607A - 003 - CB1 - PP 40 300 - AG - 607A - 034 - BD2 - PP
607A-PI-040 607A-PI-002
V-706-25

V-706-25

FC
FROM 607AAE04/607AAE05 FE 200 - AG - 607A - 035 - BD2 - PP TO 607AAM01 RING HEADER
BB1 CB1

008 CSC CSC


PP

V-515-200
EV
NOTE 2
010 AMMONIA VAPOR
G 25 - AG - 607A - 050 - BB1 - PP 5043 G
AI 607A-PI-002
S
25 - AG - 607A - 050 - BB1 - PP
I-100 A HS OPEN/CLOSE TO 607AAM01 OVERFLOW
I-101 123 010
V-406-20

ZSL ZSH HV
10 BARG STEAM 010 010 010
5050 V-401-80 V-614-80 V-103-80
80 - S10 - 607A - 011 - BB3 - HC 80 - S10 - 607A - 011 - BB3 - HC 80 - S10 - 607A - 120 - BD2 - HC
607A-PI-045
V-406-25

FO
FROM HEADER BB3 BD2
25 - S10 - 607A - 140 - BB3 - HC

H H

CONDENSATE (5 BARG)
V-405-25
T
V-601-25 25 - C5 - 607A - 066 - BB3 - PP 7942
607A-PI-046

TO HEADER
OCP SA
ODI P2

*607API001*
ST S10 C5
V-406-25

01
This drawing is the property of Jacobs Engineering. Neither this document nor any
information herein shall be copied or reproduced in any manner, loaned or otherwise
disposed of, or used for any purpose whatsoever without the prior written permission

This drawing was generated using SmartPlant and must not be altered manually. Do not Scale.
of Jacobs Engineering. If this document is loaned by or with the authority of Jacobs
Engineering, the borrower in consideration of such loan, agrees to the foregoing conditions.
ODI AT P2 SITE - DAP 607A
I REV DESCRIPTION BY CKD DATE APPD APPD APPD REV DESCRIPTION BY CKD DATE APPD APPD APPD
APPROVED
Proj. Mgr.: Z. HILAL PIPING & INSTRUMENTATION DIAGRAM I
Checker: STK
LEAD ENGINEER DATE PRENEUTRALIZER FEEDS
APPROVED
Discipline Lead: RDK
Originator: RDA
DISCIPLINE MANAGER DATE Date: 06NOV2013
APPROVED SCALE ORDER NO. DRAWING NO. REV.
CAD File: 607API001.pid

0 ISSUED FOR CONSTRUCTION VVD STK 12NOV2013 RMK OA (seal) PROJECT MANAGER DATE
NONE Q3602XXX 607A-PI-001 0