Professional Documents
Culture Documents
Inspection Report 1725 Camellia Ave 10.16.18
Inspection Report 1725 Camellia Ave 10.16.18
5415077674
travis@rogueinspection.com
http://www.rogueinspection.com
RESIDENTIAL REPORT
1725 Camellia Ave
Medford OR 97504
Rebecca & Joe Lee
OCTOBER 8, 2018
Inspector
Travis Hand
OCHI #2150
5415077674
travis@rogueinspection.com
1725 Camellia Ave Rebecca & Joe Lee
Table of Contents
Table of Contents 2
SUMMARY 5
1: INSPECTION DETAILS 7
2: ROOF 8
3: EXTERIOR 12
4: BASEMENT, FOUNDATION, CRAWLSPACE & STRUCTURE 16
5: HEATING 18
6: COOLING 19
7: FIREPLACE 21
8: PLUMBING 22
9: ELECTRICAL 26
10: ATTIC, INSULATION & VENTILATION 30
11: DOORS, WINDOWS & INTERIOR 32
12: BUILT-IN APPLIANCES 35
13: GARAGE/ CARPORT 36
14: PEST & DRY ROT 37
Introduction:
The following numbered and attached pages are your home inspection report. The
report includes pictures, information, and recommendations. This inspection was
performed in accordance with the current Standards of Practice and Code of Ethics of
InterNACHI (International Association of Certified Home Inspectors). The Standards
contain certain and very important limitations, expectations and exclusions to the
inspection. A copy is available upon request.
Scope:
A home inspection is intended to assist in evaluating the overall condition of the
dwelling. The inspection is based on observation of the visible, readily accessible and
apparent condition of the structure and its components on this day. The results of
this inspection are not intended to make any representation regarding the presence
or absence of concealed defects that are not reasonably ascertainable or readily
accessible in a competently performed inspection. No warranty, guarantee or
insurance by Rogue Inspection Services, LLC is expressed or implied. This report does
not include inspection for wood destroying insects, mold, lead or asbestos. A
representative sampling of the building components is viewed in areas that are
accessible at the time of the inspection. No destructive testing or dismantling of
components is performed. Not all defects will be identified during this inspection.
Unexpected repairs should be anticipated. The person conducting your inspection is
not a Structural Engineer or other professional whose license authorizes the
rendering of an opinion as to the structural integrity of a building or its other
component parts. You are advised to seek two professional opinions and acquire
estimates of repair as to any defects, comments, improvements or recommendations
mentioned in this report. Rogue Inspection Services, LLC recommends that the
professional making any repairs inspect the property further, in order to discover and
repair related problems that were not identified in the report. We recommend that all
repairs, corrections and cost estimates be completed and documented prior to
closing or purchasing the property. Feel free to hire other professionals to inspect the
property prior to closing, including Qualified HVAC, Plumbing, Electrical, Engineering
and Roofing Contractors.
Use of photos:
Your report includes many photographs which help to clarify where the inspector
went, what was looked at, and the condition of a system or component at the time of
the inspection. Some of the pictures may be of deficiencies or problem areas, these
are to help you better understand what is documented in this report and may allow
you see areas or items that you normally would not see. A pictured issue does not
necessarily mean that the issue was limited to that area only, but may be a
representation of a condition that is in multiple places. Not all areas of deficiencies or
conditions will be supported with photos.
Inspected (IN) = I visually observed the item, component or unit and if no other
comments were made then it appeared to be functioning as intended allowing for
normal wear and tear.
Not Inspected (NI) = I did not inspect this item, component or unit and made no
representations of whether or not it was functioning as intended and will state a
reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended,
or needs further inspection by a qualified contractor. Items, components or units that
can be repaired to satisfactory condition may not need replacement.
SUMMARY
1 35 5
MAINTENANCE ITEM RECOMMENDATION SAFETY HAZARD
8.4.3 Plumbing - Hot Water Systems, Controls, Flues & Vents: No Temperature & Pressure Relief Extension
9.3.1 Electrical - Branch Wiring Circuits, Breakers & Fuses: 2-Slot Receptacles
9.4.1 Electrical - Lighting Fixtures, Switches & Receptacles: Damaged light fixture
9.4.2 Electrical - Lighting Fixtures, Switches & Receptacles: Damaged Receptacle
9.4.3 Electrical - Lighting Fixtures, Switches & Receptacles: Broken Light Fixture
9.5.1 Electrical - GFCI & AFCI: No GFCI Protection Installed
9.6.1 Electrical - Smoke Detectors: Additional Smoke Detectors
9.7.1 Electrical - Carbon Monoxide Detectors: No CO2 Detector
10.4.1 Attic, Insulation & Ventilation - Exhaust Systems: Repair Dryer Damper
10.4.2 Attic, Insulation & Ventilation - Exhaust Systems: Replace Dryer Vent
11.2.1 Doors, Windows & Interior - Windows: Broken Window
11.4.1 Doors, Windows & Interior - Walls: Damaged interior closet wall
11.5.1 Doors, Windows & Interior - Ceilings: Water Damage - Skylight
11.8.1 Doors, Windows & Interior - Bathrooms: Damage behind toilet
11.8.2 Doors, Windows & Interior - Bathrooms: Replace Sealant Around Sink
13.1.1 Garage/ Carport - Ceiling: Moisture Intrusion
14.7.1 Pest & Dry Rot - Crawlspace: Rodent Activity
1: INSPECTION DETAILS
Information
2: ROOF
IN NI NP D
2.1 Coverings X X
2.2 Roof Drainage Systems X X
2.3 Flashings X
2.4 Skylights, Chimneys & Other Roof Penetrations X X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
Flashings: Material Skylights, Chimneys & Other Skylights, Chimneys & Other
None Roof Penetrations: Skylights Roof Penetrations: Chimney
Two (exterior)
Brick
Coverings: Material
Asphalt, Selvage
Deficiencies
Recommendation
Contact a qualified gutter contractor
3: EXTERIOR
IN NI NP D
3.1 Siding, Flashing & Trim X X
3.2 Exterior Doors X
3.3 Walkways, Patios & Driveways X X
3.4 Decks, Balconies, Porches & Steps X X
3.5 Eaves, Soffits & Fascia X X
3.6 Vegetation, Grading, Drainage & Retaining Walls X X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
Inspection Method Siding, Flashing & Trim: Siding Siding, Flashing & Trim: Siding
Attic Access, Crawlspace Access, Material Style
Visual Wood Batten
Exterior Doors: Exterior Entry Walkways, Patios & Driveways: Decks, Balconies, Porches &
Door Driveway Material Steps: Appurtenance
Fiberglass Concrete Front Porch, Patio, Sidewalk,
Carport
Deficiencies
East
The paint is failing on the front porch supports and on various locations around the house and the wood is
Rogue Inspection Services LLC Page 12 of 37
1725 Camellia Ave Rebecca & Joe Lee
The paint is failing on the front porch supports and on various locations around the house and the wood is
exposed. Recommend painting to provide a waterproof barrier and to prevent dry Rot.
Recommendation
Contact a qualified painter.
Information
Floor Structure: Floor Structure Floor Structure: Sub-floor Ceiling Structure: Ceiling
Wood Beams Plywood Structure
2x6
Roof Structure & Attic: Material Roof Structure & Attic: Type Roof Structure & Attic: Roof
Wood Gable Structure
2x6 Rafters
Deficiencies
5: HEATING
IN NI NP D
5.1 Equipment X
5.2 Normal Operating Controls X
5.3 Distribution Systems X
5.4 Presence of Installed Heat Source in Each Room X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
6: COOLING
IN NI NP D
6.1 Cooling Equipment X
6.2 Normal Operating Controls X
6.3 Distribution System X
6.4 Presence of Installed Cooling Source in Each Room X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
Distribution System:
Configuration
Central
7: FIREPLACE
IN NI NP D
7.1 Vents, Flues & Chimneys X
7.2 Lintels X
7.3 Damper Doors X
7.4 Cleanout Doors & Frames X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
Type
Gas Insert
8: PLUMBING
IN NI NP D
8.1 Main Water Shut-off Device X
8.2 Drain, Waste, & Vent Systems X X
8.3 Water Supply, Distribution Systems & Fixtures X
8.4 Hot Water Systems, Controls, Flues & Vents X X
8.5 Fuel Storage & Distribution Systems X
8.6 Sump Pump X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
Drain, Waste, & Vent Systems: Water Supply, Distribution Water Supply, Distribution
Material Systems & Fixtures: Distribution Systems & Fixtures: Water
Iron Material Supply Material
Galvanized Galvanized, Not Visible
Hot Water Systems, Controls, Hot Water Systems, Controls, Hot Water Systems, Controls,
Flues & Vents: Capacity Flues & Vents: Location Flues & Vents: Power
50 gallons Utility Room Source/Type
Gas
Limitations
Deficiencies
Recommendation
Contact a qualified plumbing contractor.
8.4.1 Hot Water Systems, Controls, Flues & Vents Safety Hazard
CORROSION
UTILITY SHED
Corrosion was noted at the burn chamber or pipe fittings.
Recommend a qualified plumber evaluate for repair/replacement.
Recommendation
Contact a qualified plumbing contractor.
8.4.2 Hot Water Systems, Controls, Flues & Vents Safety Hazard
NO STRAPS
WATER HEATER
The water heater is not strapped. Recommend securing on the upper 1/3 and lower 1/3 to studs behind.
Recommendation
Contact a qualified professional.
8.4.3 Hot Water Systems, Controls, Flues & Vents Safety Hazard
NO TEMPERATURE & PRESSURE RELIEF
EXTENSION
WATER HEATER
An extension should be placed on the T&P valve that extends within 6
inches of the floor. Recommend repair by a licensed plumber.
Recommendation
Contact a qualified plumbing contractor.
9: ELECTRICAL
IN NI NP D
9.1 Service Entrance Conductors X
9.2 Main & Subpanels, Service & Grounding, Main Overcurrent Device X
9.3 Branch Wiring Circuits, Breakers & Fuses X X
9.4 Lighting Fixtures, Switches & Receptacles X X
9.5 GFCI & AFCI X X
9.6 Smoke Detectors X X
9.7 Carbon Monoxide Detectors X X
IN = Inspected NI = Not Inspected NP = Not Present D = Deficiencies
Information
Service Entrance Conductors: Main & Subpanels, Service & Main & Subpanels, Service &
Electrical Service Conductors Grounding, Main Overcurrent Grounding, Main Overcurrent
Below Ground Device: Main Panel Location Device: Panel Capacity
Laundry Closet 125 AMP
Main & Subpanels, Service & Main & Subpanels, Service & Main & Subpanels, Service &
Grounding, Main Overcurrent Grounding, Main Overcurrent Grounding, Main Overcurrent
Device: Panel Manufacturer Device: Panel Type Device: Sub Panel Location
Walker Fuses Laundry Closet
Deficiencies
Bathroom
No GFCI protection present in all locations. Recommend licensed electrician upgrade by installing ground
Rogue Inspection Services LLC Page 28 of 37
1725 Camellia Ave Rebecca & Joe Lee
No GFCI protection present in all locations. Recommend licensed electrician upgrade by installing ground
fault receptacles in all locations.
Here is a link to read about how GFCI receptacles keep you safe.
Recommendation
Contact a qualified electrical contractor.
Recommendation
Contact a qualified professional.
Information
Attic Insulation: Insulation Type Attic Insulation: R-value Ventilation: Ventilation Type
Cellulose, Rock wool 30+ Gable Vents, Ridge Vents, Soffit
Vents
Southeast Crawlspace
Deficiencies
Information
Deficiencies
Bedroom Closet
Recommendation
Contact a qualified professional.
Information
Deficiencies
Information
Type Evidence
Pests Feces
Deficiencies