General Model DO402G

Specifications Dissolved Oxygen Converter


GS 12J05D02-00E [Style: S3]

Flexibility, reliability and low maintenance are among


the benefits provided by the EXA DO402G dissolved
oxygen converter. Designed to meet the exacting re-
quirements of measuring dissolved oxygen in the mod-
ern industrial environment, it contains many features to
ensure the best precision whatever the application.

This 4-wire converter is housed in a robust IP65,


NEMA 4X, CSA Type 3S field mountable case. Two
mA outputs, four relays, digital communication and a
clear LCD make the DO402G a truly comprehensive
package.

The DO402G features PI control on both the auxiliary


mA output and the pulse proportional relay outputs, DO402G  Dissolved Oxygen Converter
thus avoiding the need for a separate controller.

The famous EXA sensor diagnostics are now expanded


with a logbook facility in combination with the RS485
two wire communication software option. This can be
used to record events like calibration and diagnostic
messages, and to update configuration of the converter
remotely.

The DO402G accepts inputs from optical, galvanic and


polarographic sensors. Percent saturation, mg oxygen/l
water, and ppm DO can be displayed and transmitted. DO70G Optical Dissolved Oxygen Sensor
Compensation for atmospheric pressure altitude, salin-
ity and temperature are included for the best accuracy
of measurement.

Features
• Versatile sensor inputs
• On-line sensor checking monitors integrity of mem-
brane
• RS485 communications interface
• Event logbook in software
• Four fully configurable SPDT contact outputs
• Two fully configurable mA outputs DO30G Galvanic Dissolved Oxygen Sensor
• Built-in PI controller
• Easy to use EXA control panel

Refer to GS 12J05D03-01E for DO30G, GS 12J05D04-


01E for DO70G and GS 12J05C02-00E for holders.

PB350G Floating Ball Holder

Yokogawa Electric Corporation GS 12J05D02-00E


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Jun. 1997
Tel.: 81-422-52-5617 Fax.: 81-422-52-6792 7th Edition Jul. 2015
2
Accurate dissolved oxygen Barometric air pressure compensation
Air pressure differences, due to weather conditions
Operating principles or altitude, can cause a variation up to 20 % in the
The DO402G can be used with optical, galvanic and dissolved oxygen concentration. A built-in air pressure
polarographic sensors, giving added flexibility in a wide sensor automatically compensates for barometric influ-
range of applications. ences between 900 to 1100 mbar (90 to 110 kPa).
For the membrane covered electrochemical, galvanic
and polarographic, sensors, dissolved gaseous oxygen Sensor diagnostics
diffuses through the membrane, and gives rise to a DO30G sensor is checked for low impedance between
reaction at the electrodes. The resulting current is the silver electrode and an earth connection in the
proportional to the oxygen concentration in the process liquid, to detect membrane integrity. Temperature sen-
solution. sor connections and sensor connections are checked
for impedance. These faults are signaled by the FAIL
For the optical sensors, when excitation light from contact and can be signaled to the control room by an
internal LED is irradiated on a luminophore, red light is output of 22 mA or 3.5 mA (0 mA) (Burn out). The fault
generated on the luminophore through luminescence is also signaled by a special marker held on the display,
caused after excitation. a LED on the front and an error code in the message
The red light phase shift provides accurate indication of display.
oxygen concentration. The resulting current is propor- During calibration of a DO measuring system the slope
tional to the phase shift of the light. deviation from nominal value (%) and sensor output
Display functions and ranges (µA) at 0 mg/l are calculated and checked.
The display continuously gives you all necessary If any of these are outside the limits, an error is sig-
information at a glance. The process values are shown naled.
in easy readable programmable units. Either mg/l, %
saturation or ppm can be chosen.
Dissolved Oxygen concentration (mg/l)

14
The user-interface is simplified to a basic set of 6 keys
accessible through the flexible window cover. It uses a
simple step by step, question and answer style to com- 12
municate with the operator by giving messages on the
second line of the display and indicating which keys are
to be pressed in the display. 10

Automatic air calibration


Calibration for a dissolved oxygen instrument is per- 8
0
Chloride ion
formed by simple air calibration. 4
8
12 concentration
Criteria for automatic calibration (stabilization time, DO
16
(g/l)
6
values) can be set to suit the sensor. 0 10 20 30 40

In addition to the air calibration three additional calibra- Temperature (°C)


tion procedures can be used: Fig.1. Salinity compensation Output signals
1. Span calibration using air saturated water
2. Zero calibration using sulphite saturated water Outout signal
3. Process calibration using laboratory reference The standard DO402G features two 0-20 mA or 4-20
method mA current outputs available for recording, and indica-
Automatic wash cleaning (only DO30G) tion or control functions.
The DO402G can be used to generate a contact The user selectable outputs can represent:
closure to control a wash cleaning cycle. The interval, • dissolved oxygen mg/l or ppm
wash and recovery times are adjustable for optimum • saturation value %
operation. Yokogawa immersion assemblies can be • measured temperature value
supplied with wash cleaning nozzles to provide on line
cleaning for the sensor membrane or the sensor cap. In addition the following output functions are available:
Salinity compensation • a “HOLD” function that maintains last measured
In order to take the effect of salinity into account for value or a fixed value until return to normal operation
oxygen measurement an average chloride concentra- • a “BURN” function that gives a high or low output at
tion can be programmed. The chloride concentration fail status
value is set manually via the service level. The EXA • a programmable output function that allows the user
D0402G takes account of the effects of salinity and to linearize the output(s).
temperature simultaneously. The advantage of this is • a damping time constant can be set to even out
the influence of salt concentration temperature have on random process fluctuations that can make the real
the solubility of oxygen is automatically compensated, value difficult to see.
for highly accurate analyses, without the need for a
conversion table. The EXA DO402G is equipped with RS485 communi-
cation ability. Communication lines are isolated from
Temperature compensation the input and output signals. Communication speed
The micro-processor makes an accurate temperature is selectable from 1200, 2400, 4800, 9600 baud. The
compensation possible that performs well over the format is selectable for even, odd, and no parity. The
entire range of the instrument. No further adjustment DO402G can be configured over this 2-way communi-
tables are required. cation link.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00
3
Cables and terminals MAINTENANCE

The DO402G is equipped with terminals suitable for the MEASURE

connection of finished cables in the size range of 0.13 AIR.CAL


H2O.CAL

to 4 mm2 (26 to 12 AWG)


MAN.CAL
DISPLAY
HOLD

The glands will form a tight seal on cables of outside HOLD TEMP.MAN. F AIL
MODE

diameter in the range 6 to 12 mm (0.24” to 0.47”). COMMISSIONING


MEASURE
AIR.CAL SETPOINTS
YES NO H2O.CAL RANGE
MAN.CAL SET HOLD
ENT DISPLAY
HOLD
WASH
SERVICE SETPOINTS
RANGE
High Voltage Section CONTACTS SET HOLD
YES NO MODE
S1 * WASH
A B C S2

WASH/S3
ENT
FAIL/S4

SERVICE
YOKOGAWA MARKINGS
WITHIN
ENCLOSURE SERVICE

D E F
*
A B C
POWER CABLE SENSOR CABLE (S) ANALOG OUTPUTS
for DO70G or CABLE
COMMUNICATION
INPUT CONTACT *1 Fig.4. Three level operation
D E F
CONTACT (S3, S4/FAIL) CONTACT (S1, S2) POWER CABLE MAINTENANCE level
OUTPUT CABLE (S) OUTPUT CABLE (S) Use : Normal operation and checking
How : Simple operation by dialog through the
Fig.2. Glands to be used for cabling closed front cover
Example : Calibration
COMMISSIONING level
Use : For normal commissioning
How : Removal of the front cover reveals the
access key and second menu
Example : Output range setting
SERVICE level
Use : Only for specialized functions
How : Through special service code entries
Example : Selecting salinity compensation

With this 3-level user-friendly approach, the instrument


can be operated by anyone. Commissioning is straight-
Location of grounding terminal forward and needs no calibration equipment compared
(M4 Screw) F0308.ai
to analog instruments. Special functions available via
Fig.3. Grounding
access codes are invisible during normal operation.
All three levels can be separately protected against
*1: Use D or E for cable gland of DO70G power cable unauthorized access by a password system using a
when both DO70G and contact input are used. three digit code.
Three level operation General Specifications
The EXA DO402G converter uses a 3-level operating
system to take full advantage of the microproces- A. Input specifications
sor while retaining the traditional simplicity of analog : The DO402G Dissolved Oxygen
converters. Advanced functions are separated from converter measures the current
conventional operation to avoid confusion. They can be that is generated by the Dissolved
activated as required for each individual application. Oxygen sensor. The flexibility of
1.The normal maintenance functions are accessible the input circuit allows the use of
through the flexible window by pushing the keys many commercially available sen-
underneath. sors, whether they are the Galvanic
2.Functions required to commission the instrument are (driving voltage generated internal-
hidden to discourage unauthorized tampering. The ly), Polarographic (driving voltage
front cover is removed to reveal the commissioning supplied by converter) or Optical
menu and the hidden access key (marked*). (driving voltage supplied by power
3.Specialized functions can be adjusted via the SER- supply unit).
VICE menu. In this case access is by using “service The input range varies from 0.0
codes.” nA up to 500 nA for polarographic
or optical sensors and 0.0 to 50
µA for galvanic sensors. Tempera-
ture measurement for automatic
temperature compensation utilizes
Pt100, Pt1000, 22k NTC or PB36.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00
4
B. Input ranges NOTE:
- Dissolved Oxygen: 0- 50 mg/l (ppm) F
 or S4 (FAIL) LED lights when
- Temperature : 0- 50 ºC (32- 122 ºF) power is removed (Fail safe).
C. Span C
 ontact outputs configurable for
- DO concentration: minimum: 1 mg/l (ppm) hysteresis and delay time.
maximum: 50 mg/l (ppm) - Switch capacity
- % saturation : minimum: 10 % : Maximum values 100 VA,
maximum: 300 % 250 VAC, 5 Amps.
- Temperature : minimum: 25 ºC (77 ºF) Maximum values 50 Watts, 250
maximum: 50 ºC (122 ºF) VDC, 5 Amps.
- Status :H  igh/low process alarms, selected
D. Transmission signals from conductivity, resistivity and
: Two isolated outputs of temperature.
0/4-20 mA DC with common nega- Contact output is also available to
tive. signal “Hold active”
Maximum load 600 Ω. - Control function:  On / Off
Auxiliary output can be chosen from PI pulsed :  Proportional duty cycle control with
temperature, DO, PI control, table, integral term.
burn up (22 mA) or burn down PI frequency : Proportional frequency control with
(0 or 3.5 mA) to signal failure. integral term. In addition wash clean
E. Temperature compensation ing control signal on S3, and FAIL
:0  -50 ºC alarm for system and diagnostic er-
Sensor types: Pt100, Pt1000, rors on S4.
PB36 ,22k NTC K. Contact input
Automatic or Manual temperature When DO70G is connected, contact input cannot be used.
compensation. Voltage-free contact (do not apply voltage)
F. Calibration : Semi-automatic calibration with Wash start or input remote range change (either choice)
automatic compensation for influ- On resistance: 10Ω or less
ence of barometric pressure and Off resistance: 100kΩ or more
altitude on partial pressure of Oxy- On time: 0.5 sec. or more
gen in air (or solubility of Oxygen Note: At the circumstance influenced from noise (e.g.
in water). Automatic compensation long transmission of contact input), insertion of a
for influence of salinity of water relay near DO402G is recommended for insulat-
on solubility of Oxygen in water is ing.
programmable. L. Power supply:
The correction for pressure, salin- Voltage ratius (Applicable range): 
ity and temperature meets ISO 100 V (85 to 115 V) AC
5814 115 V ( 97.8 to 132.2 V) AC
Possible calibration routines are: 230 V (195.5 to 264.5 V) AC
-S  lope (span) calibration in ambient Supply frequency rating (Applicable range):
air. The calibration table is based 5
 0 / 60 Hz (± 5%)
on 70% rH and is determined Power consumption: 10 VA maximum for steady
empirically. operation
-S  lope (span) calibration in water, M. Safety and EMC conforming standards
saturated with air: according Safety: conforms to EN 61010-1
ISO 5814 EN 61010-2-030
- Zero calibration (normally inactive) CAN/CSA No.61010-1
G. Serial communication UL Std. No. 61010-1
: Bi-directional
 according to the CSA C22.2 No. 94.2
EIA-485 standard using HART®- UL 50E
protocol and PC402 software.. EMC: conforms to EN 61326-1 Class A,Table 2
(For use in industrial locations) (Note 1)
H. Logbook : Software record of important
EN 61326-2-3
events and diagnostic data.
EN 61000-3-2 Class A
Available through RS485, with key
EN 61000-3-3, AS/NZS CISPR 11
diagnostic information available in
EMC Regulatory Arrangement in Australia
the display.
and New Zealand (RCM)
I. Display : Custom liquid crystal display, with EN 55011 Class A, Group 1
a main display of 3 1/2 digits 12.5 Korea Electromagnetic Conformity Stand-
mm high. Message display of 6 ard Class A 한국 전자파적합성 기준
alpha­numeric characters, 7 mm high.
J. Contact outputs Category based on IEC 61010: II (Note 2)
- General : Four (4) SPDT relay contacts with Pollution degree based on IEC 61010: 2 (Note 2)
LED indicators. For S1, S2, and S3, Installation altitude: 2000 m or less
the LED is on when relay is pow- Note 1: This instrument is a Class A product, and it is
ered. designed for use in the industrial environment.
Please use this instrument in the industrial envi
ronment only.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 22, 2015-01
5
Note 2: Installation category, called over-voltage J. Automatic safeguard : R eturn to measuring mode
category, specifies impulse withstand voltage. when no keystroke is made
Category II is for electrical equipment. for 10 min.
Pollution degree indicates the degree of
existence of solid, liquid, gas or other inclusions K. Power interruption: Less than 50 milliseconds no effect.
which may reduce dielectric strength. Degree 2
is the normal indoor environment. L. Operation protection: 3
 -digits programmable
password.
Operating Specifications
M. Connection cable: When use DO30G, the dis-
A. Performance : DO (at t process = 25 °C) tance between sensor and the
- Linearity :± 0.03 mg/l or ± 0.5%FS, whichever transmitter will be maximum
is greater 50m if WTB10 terminal box is
- Repeatability : ±
 0.03 mg/l or ± 0.5%FS, whichever connected.
is greater (DO70G cannot connect to
- Accuracy :± 0.05 mg/l or ± 0.5%FS, whichever WTB10. The distance between
is greater DO70G and the transmitter is
always maximum 10m.)
B. Performance : Temperature (Pt1000, 22k NTC,
PB36) Model and suffix codes
- Linearity : ± 0.3 ºC
- Repeatability : ± 0.1 ºC [Style: S3]
- Accuracy : ± 0.3 ºC
Suffix Option
Performance : Temperature (Pt100) Model Description
code code
- Linearity : ± 0.4 ºC
DO402G ---------------- ---------- Dissolved Oxygen Con-
- Repeatability : ± 0.1 ºC verter
- Accuracy : ± 0.4 ºC
Type -1 ---------- General
Note on performance specifications: Power Supply -1 ---------- 115V +/-15% AC, 50/60 Hz (*2)
The specifications are expressed Voltage -2 ---------- 230V +/-15% AC, 50/60 Hz
with simulated inputs, because the -5 ---------- 100V +/-15% AC, 50/60 Hz
DO402G can be used with many Language -E ---------- English
different sensors with their unique -J ---------- Japanese
characteristics.
The following tolerance is added to Options
Mounting Bracket /U Pipe, wall mounting
above performance. bracket (Stainless steel)
mA output tolerance : ± 0.02 mA of /PM Panel mounting bracket
"0/4 - 20 mA" (Stainless steel)
Digital display tolerance : +1 digit Hood /H3 Hood for sun protection
C. Response time (Carbon steel)
0- 90% : 10 s /H4 Hood for sun protection
(Stainless steel)
D. Ambient operating temperature Tag Plate /SCT Stainless steel tag plate
:-10 to + 55 °C (14 to 131 ºF) Conduit Adapter /AFTG G 1/2
/ANSI 1/2 NPT
Coating /X1 Epoxy baked finish (*1)
E. Storage temperature
: -30 to +70ºC (-22 to 158 ºF) *1: The housing is coated with epoxy resin.
*2: When CSA safe standard conformity product
is needed, select 115V “-1” of Power Supply
F. Humidity : 10 to 90% RH non-condensing
Voltage.

G. Housing
- Case :C ast aluminum with chemically
resistant coating
- Cover : Flexible polycarbonate window
- Case color : Off-white (Munsell 2.5Y8.4/1.2)
- Cover color : Moss green (Munsell 06GY3.1/2.0)
- Cable entry : Via six PG13.5 nylon glands
- Cable terminals : For up to 2.5 mm2 finished wires
- Protection :W eather resistant to IP65, NEMA
4X, CSA Type 3S
- Mounting :P ipe wall or panel, using optional
bracket.

H. Data protection: Lithium battery for clock support.

I. Watchdog timer: Checks microprocessor

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Oct. 27, 2015-02
6
Control and Alarm Functions Fault alarm :C
 ontact S4 by default set to
function as an alarm, indicating
Control output (mA) that the EXA has found a fault
: Pl control on the 2nd mA output. in the measuring loop. If the self
The 2nd mA output can be con- diagnostics of the EXA indicate a
figured to give a P/I (proportional fault or error, the FAIL contact will
and integral) control output. The be switched. In most cases this will
setpoint, proportional band and be caused by a malfunction of the
integral time are each fully pro- measuring loop. The FAIL contact
grammable. is also closed when the power is
- Adjustable parameters removed.
:S etpoint, proportional range and The “FAIL” contact may also be
integral time. configured as a fourth process
alarm.
% duty cycle control
Process alarm : T  he contact will be switched when 100 toff > 0.1 sec
the process value reaches a limit.
This can either be a high or low
limit. Duty cycle
- Adjustable parameters
: Setpoint for the process value
Hysteresis of the switching action 50% 50%
Delay time of the relay (0 to 200 s) 50
ton toff
Duty cycle
PI duty cycle control (Fig. 5)
: The contact is used to control the ton > 0.1 sec
time a solenoid valve is opened.
The proportional control is achieved 0 Duty cycle
by opening and closing the sole- Proportional DO
noid valve and varying the ratio of Setpoint Range % of output range Time
on and off time (on, off).
- Adjustable parameters Fig. 5. Duty cycle control
:S  etpoint, proportional range and in-
tegral time. Total period of the pulse % controller output 0.3 s
period (5 to 100 s) 100
PI pulse frequency control (Fig. 6)
Maximum pulse frequency
: The contact is used to control a
pulse-driven pump. 0.3 s
The frequency of pulses regulates
the pump speed.
- Adjustable parameters 50
50% pulse frequency
: Setpoint, proportional range & inte-
gral time. Maximum pulse frequency
(50 to 120/min.)

Wash cleaning of sensors (Fig. 7) No pulses


: Contact
 S3 is used to control the 0
Proportional DO Time
wash cycle, or as a process alarm. Setpoint Range % of output range
- Adjustable parameters
:C leaning time or washing time (tw) Fig. 6. Pulse frequency control
Recovery time after washing (tr)
Interval time for wash cycle.
The graph shows a typical response
curve during washing. The wash DO
and recovery times need to be set
to suit the process.

Wash Recovery
tw tr
Interval Time
Time

Fig. 7. Dynamic response during wash

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00
7
External Dimensions
DO Converter DO402G

Unit: mm (inch)
Hood (optional)
Option code : /H□
Four M6 screws, 8 (0.31) deep
184 220
(7.24) (8.66) 80
(3.15)

72
(2.83)

144 20 (0.79)
(5.67) 80
(3.15)

144 23 112
(5.67) (0.91) (4.41) Adaptor for conduit work
(option code : /AFTG, /ANSI)

Cable inlet port (Six-21 (0.83) dia. holes)


DIN PG13.5 cable gland

Approx. 55 (2.17)
A B C A : Power supply for DO70G, or
contact input separately.
36 (1.42) B : Sensor cable Adaptor 49
C : Output signal (1.93)
D : Contact output (S3 and S4)
D E F 38 (1.50) E : Contact output (S1 and S2)
F : Power supply
36 36
(1.42) (1.42) G 1/2 female ( / AFTG)
Ground terminal 1/2 NPT female ( / ANSI) Weight: Approx. 2 kg
(M4 screw *) *: Tightening torque: 1.2 N·m.

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00
8
Pipe/Wall Mounting Brackets (Option Code: /U) Weight: approximately 0.7 kg
Example of bracket used for pipe mounting
Unit: mm (inch)
188
(7.40) M6, 4 screws *

174
(6.85)
200
(7.87)

50
(1.97)

Nominal 50A (O.D 60.5mm) 100


mounting pipe (3.94)

Example of bracket used for wall mounting

135 13 M6, 4 screws *


(5.31) (0.51)

224
(8.82) 200
(7.87)

35 (1.38)

15 (0.59)

70 (2.76)
*: Tightening torque: 2 N·m. 10mm dia., 3 holes 100 (3.94) F14-1.ai
(0.39)

Example of bracket used for panel mounting (Option Code: /PM) Weight: approximately 0.4 kg
23 (0.91) M6, 4 screws *
12 max.(panel thickness)
(0.47) Panel cutout dimensions

M5, 2 screws

100 137 +20


(3.94) (5.43)

137 +20
178 (5.43)
(7.01) *: Tightening torque: 2 N·m. F14-2.ai

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00
9
System Configuration

FRONT GLANDS REAR GLANDS

SENSOR POWER

S1
CONTACT
OUTPUT
0/4-20mA S2
OUTPUT
SIGNALS
0/4-20mA

S3/WASH
CONTACT
OUTPUT
S4/FAIL
RS485

CONTACT
INPUT

Input and Output Connections

Contact Digital
Input Sensor Inputs mA Outputs Communications

21 22 14 13 17 11 12 18 16 15 63 66 65 62 61 95 94 93 92 91
SCREEN Liquid mA2 mA1 TL TL
Shield earth SCREEN SCREEN

23 Temp 99
SCREEN 2

CONT SENSOR mA OUTPUT RS485


- - - polarographic or optical sensor galvanic sensor

Relay Contacts Power Supply

71 72 73 51 52 53 41 42 43 31 32 33 3 2 1
G N L
250VAC 250VDC FUSE
5A 5A
100VA 50W
100 VAC 200 mA
115 VAC 200 mA

C NC NO C NC NO C NC NO C NC NO 230 VAC 100 mA 250VAC; T

S4 S3 S2 S1

High voltage area

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00
10
Inquiry Specifications Sheet for Dissolved Oxygen Analyzer

Make inquiries by placing checkmarks () in the pertinent boxes and filling in the blanks.

1. General information
Name of your company:
Name of inquirer: Dept. or sect.: (telephone: )
Name of plant:
Measuring point:
Purpose of use:  Indication  Record  Alarm  Control
Power supply: V AC

2. Measuring conditions
(1) Liquid temperature: to , normal [˚C]
(2) Liquid pressure: to , normal [kPa]
(3) Flow rate to , normal [m/s]
(4) Name of liquid:
(5) Composition of liquid:
(6) Other remarks:

3. Installation environment
(1) Ambient temperature:
(2) Location:  Outdoors  Indoors
(3) Other remarks:

4. Specification requirements
(1) Measuring range:  0 to 50 mg/l, 
(2) Output signal:  4-20 mA DC,  0-20 mA DC
(3) System component selection :  Sensor  Converter  Power supply unit for DO70G  Terminal box
 Holder  Cleaning system  Parts set for maintenance  Calibration set
(4) Length of sensor cable :    3 m  5 m  10 m  15 m  20 m
(5) Type of holder :  Guide pipe  Submersion  Floating ball  Suspension
(6) Cleaning method :  No cleaning  With jet cleaning
(7) Other remarks:

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 12J05D02-00E 7th Edition Jul. 21, 2015-00

Subject to change without notice.

You might also like