AAM Manual Builder 2ed
AAM Manual Builder 2ed
AAM Builder
User Manual
Copyright Notices
©2006 Yokogawa Electric Corporation
Unless agreed in writing by Yokogawa Electric Corporation, the licensee shall not remove, release,
disclose, reveal, copy, extract all or part of the documentation.
Highlights
The Highlights section gives details of the changes made since the previous issue of this
document.
Summary of Changes
Detail of Changes
The changes are as follows:
Chapter/Section/Page Changes
1st Edition Based on AAM Version 1.0
2nd Edition Updated based on AAM Version 2.0
Functional Design
Specification-Alarm
Management System (NMR
601.21)
TABLE OF CONTENT
T1 INTRODUCTION ........................................................................................................ 6
T
3.4 Security.............................................................................................................................................................16
3.4.1 Setting Security for the Administration Screens........................................................................................17
3.4.2 Setting Security for the Operation Screens................................................................................................18
3.4.3 Default User...............................................................................................................................................19
4.4 AAM-Enforcer.................................................................................................................................................53
4.4.1 AST Builder...............................................................................................................................................53
4.4.2 Tag Monitor...............................................................................................................................................70
4.4.3 Shift/Enforcement PC................................................................................................................................75
4.4.4 Audit Trail Viewing...................................................................................................................................79
1 Introduction
This document describes the details of UI (User Interface) Screens and Software Structure of AAM
Builder Module for Advanced Alarm Manager (AAM) package. It will be used as the basis for the Client
operation.
This preliminary manual is based on the trial AAM software and shall be updated based on the final
version of AAM software.
1.1 Introduction
Yokogawa Advanced Alarm Management (AAM) system provides alarm documentation, alarm
enforcement on Yokogawa DCS, statistical reports on alarms, alarm enforcement and alarm
rationalization reports, and Sequence of Event reports.
AAM provides the capability of analyzing alarms and events and collecting and storing modifications to
alarm configuration data. All reports are viewed via the web, and only engineering and alarm database
enforcement functions are restricted to AAM client.
Yokogawa AAM has been developed based on the following functional and operational considerations:
o Ability to retrieve alarm settings from the DCS to form the initial master alarm database. The
master alarm database also consists of alarm documentation which has to be manually
entered.
o Ability to modify the master alarm database and enforce the alarm settings in the master alarm
database into the DCS.
o Ability to view and store alarm data from PCS which includes Yokogawa DCS system and
Triconex ESD systems
o Ability to analyze the occurrence of alarms and various statistical reporting based on EEMUA
publication number 191.
o Ability to view modifications of alarm configuration data using web browser
o Ability to view alarm data.
Yokogawa AAM consists of three basic functions based on the above operational and operational
characteristics:
AAM Statistical AAM Statistical Report enables user to view, analyze, and manageall
Report the larm and event messages collected and stored in the AAM
database.
IM 052006-A01 2ND EDITION ISSUE 22 MAY 2006 PAGE - 6
AAM MANUAL BUILDER R100
Yokogawa AAM user manual is based on the following functional hierarchy. Users may refer to the
respective manual for details:
AAM Builder
Tag Monitor
Shift/Enforce
ment PC
Audit Trail
Viewing
On-demand
Request
System
Configuration
Function
Block
Uploading
Tag Hierarchy
AAM Client
Implemented AST
AAM Client Daily
Operation
AST Operation
Alarm Advisor
Report
On-demand Enforcement
This section serves as the ‘dictionary’ for the many AAM-related phrases and words used unsparingly in
upcoming sections and chapters to describe AAM Enforcer.
Terms Descriptions/Definitions
AAM Advanced Alarm Management
AAM Enforcer To enforce alarm settings in the master alarm database into the DCS.
DCS setting are read from the OPC servers and entered into the alarm
database. The initial master alarm database may be generated using
the initial upload of DCS alarm settings, and rationalization or
management of change performed on the master alarm database.
Additional Tag info “Additional Tag Info” refers to the following informational items
attached to each AST tag:
o Tag Comment;
o SH;
o SL
o ENGUNIT
o Alarm Priority
o Safety Critical
o Equipment ID
o Source Doc
o MOC#
o Highest Computed Priority
Alarm acknowledgement Time for operator to acknowledge alarm after the alarm is activated.
threshold
Alarm Advisory Messages “Alarm Advisory Messages” refers to the informational items attached
to each AST tag on a per alarm-limit-parameter basis for advisory
purpose. The alarm advisory message may include:
1) Purpose
Purpose of this alarm (the hazard or process condition that the alarm
intended to detect)
2) Consequence
Consequence of this alarm.
3) Actions to Verify
Actions the operator should take to verify the process condition.
4) Actions to Correct
Actions the operator should take to correct the process condition.
5) Severity
Severity of the consequences in safety, environmental, and economic
terms associated with the alarm. Possible values are ‘High
Consequence’, ‘Medium Consequence’, ‘Low Consequence’.
6) Response Speed
Time required for the corrective actions to be performed and to have
the desired effect in response to the alarm. Possible values are ‘<15
minutes’, ’15-45 minutes’, ‘>45 minutes’.
7) Computed Priority
Priority of Alarm computed based on selections of “Severity” and
“Response Speed”. The Priority Computation table is as illustrated
below:
Severity
High Medium Low
Response
< 15 mins 1 1 2
15 – 45 mins 1 2 3
> 45 mins 2 2 3
Alarm limits Refers to the alarm threshold parameters of an AST/DCS tag. For
AAM software, the followings are supported:
HH : High High alarm limit
PH : Process High alarm limit
PL : Process Low alarm limit
LL : Low Low alarm limit
DL : Deviation Limit
VL : Velocity Limit
Applying AST “Applying AST” means sending the “Alarm Setting” for all selected tags
in the selected AST, to the DCS.
1) Master AST type (one for each area in plant hierarchy; each
AST contains all the tags covered by the area). Master ASTs are auto-
built by AAM software, and cannot be removed.
AST Header “AST Header” refers to the information comprising the followings:
o AST Name
o Description
o Author Name
o Unit Name
Change DCS PH/PL “Change DCS PH/PL” means changing the PH/PL limit values of one
selected tag in DCS to their new values. This action is not considered
as AST-related action, and AAM does not record their changes into
Implemented Alarm DB.
Enable DCS Alarm(s) “Enable DCS Alarm(s)” means changing the AOFS values of all
selected tags in DCS to AON (Alarm ON). This action is not
considered as AST-related action, and AAM does not record their
changes into Implemented Alarm DB.
Highest computed priority Highest Computed Priority for the AST tag
IAD Implemented Alarm DB
Implemented Alarm DB Current implemented alarm setting database.
“Implemented Alarm DB” (IAD) starts off the same as the MAD. When
a user starts to apply any user-defined AST to DCS, Implemented
Alarm DB will be updated, and will no longer be the same as MAD.
Plant Hierarchy “Plant Hierarchy” refers to the ‘tree-structure’ layout of the plant
hierarchy comprising of one plant, many areas, and many units.
Suspending Tag’s Alarm Every tag in Implemented Alarm DB has two attached parameters:
Setting Enforcement “SuspendFrom” and “SuspendTo”. By default, these parameters are
IM 052006-A01 2ND EDITION ISSUE 22 MAY 2006 PAGE - 11
AAM MANUAL BUILDER R100
Tag Hierarchy “Tag Hierarchy” refers to the ‘where-about’ information of an AST tag
in plant hierarchy. The where-about information includes the
followings:
o Plant Name
o Area Name
o Unit Name
User-defined AST “User-defined AST” refers to the AST formed by using AST Builder,
based on user’s selection of tags, and other details.
Also refer to “AST”
User-defined AST DB Refers to entire set of “User-defined ASTs” for the AAM software.
When using the AAM software, references to elements of plant hierarchy is prevalent.
The figure below illustrates the plant hierarchy as applied to Riyard Refinery. There is a single plant
(named “Riyadh Refinery”), eight areas (named “Area D”, ”Area E”, “Area G”, “Area H&I”, “Area J”,
“Area Util”, “Area WTP”, “Ccr FCS”), and there is one unit for each area.
When a user logs in to the AAM client, the software will first determine his areas-of-responsibility. As an
example, if this operator is responsible for operating “OPC1” area, then he will be allowed to apply
alarm settings found in ASTs for “OPC1”.
The figure below illustrates the relationship between “Area” and “Plant Hierarchy”:
AAM software
Area Area
Area “OPC5”
“OPC1” “OPC3”
Area
Area Area
“OPC6”
“OPC2” “OPC4”
1) Areas must not overlap. This means that a DCS tag assigned to “OPC1” area cannot be
attached to another area at the same time.
2) Area name must be unique within a plant. However, this version of AAM software supports
only a single plant; so the possibility of seeing “OPC1” area in another plant other than
“Refinery” is not present.
The figure below illustrates the relationship between “Area” and “AST”:
AAM software
Area “OPC1”
AST “MAST_OPC1”
AST
“LN Mode” AST
“HN Mode”
AST
“CDU2”
AST
“AST1”
1) Every area will be automatically configured by AAM software with an “un-removable” Master
AST (named as “MAST_<areaname>”) to include all tags under <areaname> area. In above
example, “MAST_OPC1” is an AST containing all tags assigned to “OPC1” area. The tags
which are viewable in “Implemented Alarm Screen” are selected by area (the list of areas is
derived from the areas-of-responsibility of the logon user), and are therefore the same tags as
“MAST_<areaname>” AST for the selected area.
2) AST cannot cross areas. For example, it will NOT be possible to build an AST containing one
tag in “OPC1” and another from “OPC2” area. The current version of AAM software will NOT
allow user-defined AST to cross units too.
The figure below illustrates the relationship between “Area” and “ExaOPC”:
AAM software
1) AAM software exchanges data with DCS systems using one or more ExaOPC servers.
3) Each ExaOPC server has a temporary area to serve as its “Default Area” (or “Upload Area”).
New tags defined in DCS system (yet-to-assign to plant hierarchy) shall arrive at the
default/upload area.
3.4 Security
This section covers built-in users, functions (permissive), and default security settings.
The table below summarizes the built-in users and their default security settings in the AAM software:
In the above table, “AAMadmin” is the system-defined (not removable) user with full permission (not
configurable). “Engineer” is also system-defined, but his permission can be configured.
The details of “Permissive” items for Administration screen type are described as below:
Permissive Description
Specifying permission to “create AST” provides the user with the
Create AST
authority to generate new AST.
Specifying permission to “edit/save AST” provides the user with
Edit/Save AST
the authority to change contents of AST.
Specifying permission to “delete AST” provides the user with the
Delete AST
authority to remove AST.
Specifying permission to “copy AST” provides the user with the
Copy AST
authority to generate a new AST from an existing one.
Specifying permission to “edit/save plant hierarchy” provides the
Edit/Save Plant Hierarchy
user with the authority to change the plant hierarchy tree.
Specifying permission to “edit/save tag hierarchy” provides the
Edit/Save Tag Hierarchy user with the authority to assign tags to a plant hierarchy
location.
Specifying permission to “access system/admin audits” provides
Access System Audits
the user with the authority to read system audit trails.
Specifying permission to “edit/save operation parameters”
Edit/Save Operation Parameters provides the user with the authority to configure operation
parameters such as shifts and enforcement.
Specifying permission to “edit/save system parameters” provides
the user with the authority to configure system parameters such
Edit/Save System Parameters
as ExaOPC server’s details and Oracle DB housekeeping
configurations.
Specifying permission to “edit/save security settings” provides
Edit/Save Security Settings the user with the authority to add/remove user and configure his
permissions.
Specifying permission to “Access Tag Monitor” will allow the
Access Tag Monitor user to be notified when a new tag has been detected by the
system
Specifying permission to “Upload Tag Info” provides the user
Upload Tag Info with the authority to upload a new tag into the list of available
tags in the system.
The details of “Permissive” items for Operation screen type are described as below:
Permissive Description
Specifying permission to “access AST” provides the user with
Access AST
the authority to access AST listing and AST details.
Specifying permission to “apply AST” provides the user with the
Apply AST
authority to send alarm settings of UAST tags to DCS.
Specifying permission to “apply AST” provides the user with the
Apply Master AST
authority to send alarm settings of Master AST tags to DCS.
Specifying permission to “access alarm advisor” provides the
Access Alarm Advisor user with the authority to search for tags to display their full
alarm settings.
Specifying permission to “enable DCS alarm” provides the user
Enable DCS Alarm
with the authority to send AON requests to DCS tags.
Specifying permission to “disable DCS alarm” provides the user
Disable DCS Alarm
with the authority to send AOF requests to DCS tags.
Specifying permission to “suspend enforcement” provides the
Suspend Enforcement user with the authority to specify date/time range for suspension
of alarm setting enforcement for selected tags.
Specifying permission to “resume enforcement” provides the
Resume Enforcement user with the authority to specify removal of alarm setting
enforcement suspension for selected tags.
Specifying permission to “change DCS PH/PL” provides the user
Change DCS PH/PL
with the authority to send PH/PL change requests to DCS.
Specifying permission to “access operation reports” provides the
Access Operation Reports
user with the authority to view and print reports
Specifying permission to “execute on-demand enforcement”
Execute On-demand Enforcement provides the user with the authority to perform an on-demand
enforcement
Specifying permission to “change own password” provides the
Change Own Password
user with the authority to change his/her own password
Specifying the areas of responsibility provides the user with the
authority to access ASTs and tags covered by the areas. The “*”
Areas of Responsibility string is used to specify all areas. For operator in general, this
string can be “OPC1”, or “OPC1,OPC2”, etc. where multiple
areas are separated by comma.
A default user can be defined on each client PC. If a default user is defined, the login screen will be
skipped when the AAM Client Application is started. The AAM Client Application will be launched
immediately with the default user as the login user. This default user must be defined in the AAM
database as well as the Windows Registry. The required entries in the Window Registry are as follows:
The AAMDefaultUserPassword is the password for the default user. Any change of password for this
user must be updated here.
The AAMTimeOutMins defines the number of minutes allowed for other users to use the AAM on this
PC.
The figure below illustrates the general layout of the AAM Builder:
In general, you need to use either “pull-down main menu”, “tool bar”, or “side bar” to display the
AAM builder function in the “main display area” to start using the AAM builder.
The figure below illustrates the screen hierarchy or screen organization of the AAM Builder:
AAM Builder
Common
User Security
System Configuration
Function Block
Uploading
Tag Hierarchy
AAM-Enforcer
AST Builder
Tag Monitor
Shift / Enforcement PC
Audit Trail Viewing
AAM-Report
Configuration
On-Demand Request
To execute AAM Builder function, logon on as user with “AAM Builder” access privilege. User
without “AAM Builder” access privilege will be denied access to AAM Builder.
Note: The logon user shall have AAM Builder access rights to logon. Otherwise the access
request will be denied.
For more on details on the user security setting, go to “User Security” for details.
The AAM Builder software has the following functions for AAM-Common module:
1. User Security
• Manage user security configuration
2. System Configuration:
• Configure (i.e. add/edit/delete) an ExaOPC server, and manage database
housekeeping configuration
3. Function Block:
• Manage function block types registration
4. Uploading:
• Upload (read and update) alarm configuration database
5. Tag Hierarchy:
• Build plant and tag hierarchy
The figure below summarizes the screen flow and key functionalities of Security Configuration
Screen:
User security setting can be configured with AAM Common function, assigning respective
permissive items or rights for each type of user account.
There are two default users, namely “AAMadmin” and “Engineer”, created by AAM which can not
be deleted from the system. Additional users can be created using “Add a new user” function.
Access rights are displayed in the right pane of the screen for each selected user, as illustrated
below.
Please refer to “Add a new user” to how to create a new user account.
This is to create a new user account. Below is the illustration of creating a new user account.
Note: This function is only accessible to logon user with “Change Own Password” OR
“Edit/Save SECURITY Setting” access rights.
Step 6: Check to grant this new user access rights as below. Uncheck to deny access rights.
Step 7: Assign Areas of Responsibility. Click the “Area of Responsibility” dropdown list as
below. Select the Area for the newly created user and click the Area Add button.
Note2: A comma separated string of areas will be formed if more than one area is
selected.
User security setting can be edited using “Edit” insert “edit button” function, depending on the
access privileges assigned to the logon user. General steps are described as below:
Step 1: Select the name of the user for which security setting needs to be edited. A “Edit User”
window will pop-up.
Step 3: New set of password can also be created, if the user has the privilege of “Change Own
Password” OR “Edit/Save SECURITY Settings”.
Step 5: Click “Areas of Responsibility” dropdown list to edit the area of responsibility.
Note: To delist area(s) the user is responsible for, press “clear” button to empty
the selected area field first before selecting new Areas of Responsibility.
Note: To assign more Area of Responsibility to the user, selected the areas from the
droplist and click button to confirm.
PAGE - 27
ND
IM 052006-A01 2 EDITION ISSUE 22 MAY 2006
AAM MANUAL BUILDER R100
AAM also allows a new user account to be created using “Copy” function. General steps are
described as below:
Step 4: A new account will be created, with the SAME security setting as the original user
selected.
Step 5: If any security setting for the newly created user need to be edited, refer to step “Edit user
security setting” for details.
A user can be removed from the currently system user list, using “Delete” function. General steps
are as below:
Step 3: A dialog box will pop up. Press Ok to proceed to delete the selected user, or
press “Cancel” to cancel deleting user.
Two functions can be achieved with System Configuration under AAM Builder:
• OPC Server configuration;
• Database Housekeeping configuration.
Please refer to the below for details.
To access System Configuration, logon to AAM Builder using user account with “AAM Builder”
access rights. Screen and key functionalities of “System Configuration” will be as below:
Step 1: Press Add button , to popup the “Add OPC Server” dialogue box.
Step 2: Enter “Server Name” and “XX PROGID” information for new OPC server. Click “OK” to
confirm.
Step 1: Select an OPC Server, by clicking on one of the selection boxes at the left side of “OPC
Server” data grid.
Step 2: Use “Delete” button to delete the selected OPC Server. A dialogue box will appear.
Note: If no OPC server has been selected, the following dialog box will be displayed.
Step 2: Press “Edit” button to pop-up the “Edit OPC Server” dialog box.
Note: Only one server can be selected at one time for editing. If no server or more than
one server has been selected, pressing “Edit” will pop up a dialogue box as below.
Step 3: Update “Server Name” and “XX PROGID” information, and click “OK” to confirm.
This function is only accessible to a logon user with “Edit/Save System Parameters” access right.
Step 2: Enter the number of days to keep data for the respective tables, and click OK to confirm
the editing.
The screen below summarizes the screen flow and key functionalities of “Function Block” tab of
AAM Builder.
To add more function block types to registered list, follow the guiding steps below:
Step 1: Use “Add” Button to pop-up the “Add Function Blocks” dialog box as below:
Step 2: Use the check box next to Function Block column in data grid to individually select function
block types for registration with AAM Historian.
Step 3: Use “Selection String” textbox together with “select” and “unselect” buttons for “Bulk select”
or “Bulk unselect” function.
Step 3: Press “OK” button to proceed with deleting the function block. Press “Cancel” button to
terminate deleting the function block.
4.3.4 Uploading
Step 1: Select an OPC server (together with its PROGID) using the dropdown list box for the “OPC
Server” input field.
“DA PROGID” information is automatically retrieved with the selected “OPC Server” based on
configuration already done in “Configure” tab.
Step 2: Enter “Number of Retries” parameter for handling unsuccessful requests to OPC Server.
Step 3: Enter “Delay between Requests” parameter for slowing down of continuous stream of
requests to OPC Server.
Upon successful connection, status bar will displayed “<station> connected” message. The
“Disconnect” button will be enabled, to allow you to cut the connection to ExaOPC server.
Upon unsuccessful OPC server connection, an error message box will appear as below:
Upon successful disconnection, status bar will displayed “<station> disconnected” message. The
“Connect” button will be enabled, to allow you to make the connection to ExaOPC server.
AAM enable user to read tag and update alarm configuration from OPC server in three optional
ways:
• From all FCS stations, or
• From one specific FCS station, or
• From selected tags.
4.3.4.3.1 Read tag and update alarm configuration from ALL OPC Server and Update AAM
To read from ALL connected OPC Server and Update AAM, follow the steps as below:
Step 1: Click on the “All Stations” radio button. Then click on “Read” button
You will be asked to confirm your choice of uploading from all FCSs covered by the
connected OPC server, as illustrated by the figure below:
To read tag and alarm configuration from on FCS, follow the guiding steps as below:
Step 1: Click on the “One Station” radio button. Then Select a FCS using the dropdownlist
box for the “FCS Station Name” input field.
To read tag and alarm configuration for selected tags, follow the uiding steps as elow:
Step 1: Click on the “Tags Selected by User” radio button. Then Select a FCS using the
dropdownlist box for the “FCS Station Name” input field.
Step 3: Click on checkboxes next to tag name individually, or use text selection string
together with “Select”/”Unselect” buttons. End selection with “OK” button.
All plant tags can be organized based on a tag hierarchy using AAM Tag Hierarchy function.
Illustrated below is the window frame of the Tag Hierarchy:
Step 2: Press Edit button and a dialogue box will display as below:
Step 4: Complete Plant Editing by pressing “OK” button. Press “Cancel” to terminate Plant editing.
Plant Area can be added, edited or deleted by AAM Builder, following the guiding steps below:
• Add Area
Select or highlight the plant name
Enter Area Name, Description (can not be blank), and OPC Server. Press “OK” to
proceed or Press “Cancel” to terminate the Add Area function.
• Edit Area
Select Area to be edited.
• Delete Area
Select Area to be deleted.
Note: If the area to be removed is attached with Units, it can not removed and an
error message will be displayed as below:
• Add Unit
Enter Unit Name and Description. Press “OK” to proceed or “Cancel” to cancel
adding a new unit.
• Edit Unit
• Delete a Unit
The figure below summarizes the screen flow and key functionalities of Tag Hierarchy Builder pop-
up screen:
■ Select a unit in Plant\Area hierarchy window. Area and unit information will appear on top
of the tag download area.
Area and unit information will appear on top of the tag download area.
■ Select the FCS station name. Information of all tags from the selected FCS station will be
displayed as below.
Note: If “*” instead of a specific FCS station has been selected, all tags assigned to the
Unit will be displayed.
■ Users can use tag movement buttons as below to move tags between tag upload area
where all available tags for building tag hierarchy are listed and tag download area for tag
hierarchy configuration.
Note: when move tags from “Available tags for building tag hierarchy” area to tag hierarchy
building area or download area, the tag will be automatically assigned to the specific FCS
stations.
■ To remove unwanted tags from the Upload Area, follow the steps as below:
4.4 AAM-Enforcer
AAM Builder software has the following operational functions for AAM Enforcer module:
• AST Builder
• Tag Monitor
• Shift/Enforcement PC
• Audit Trail Viewing
The figure below summarizes the screen flow and key functionalities of AST Builder by using
A master AST for this specific area and other user-defined ASTs will be displayed as below. Select
the specific AST and all tags under the specific AST will be displayed as below.
Step 1: Click “Add” button to pop up a “Add AST” dialogue box as below. Enter information in
the areas of AST Name, Author, and Description.
Note 1: All areas MUST be filled and can not be left blank.
Note 2: Default name of “Author” is the logon user with “Access Builder” rights. Entered
name of the use must have same User Security level.
Note: All tags for the newly created AST MUST from same unit in AAM Enforcer function.
Step 3: Select tags from “Available tags” area to be added to the newly created AST, as shown
above.
Note: User can also use a tag selection filter and click “Show selected one” to
select/unselect tags.
Step 4: Use following buttons to Add, Add All, Remove, Remove All tags between “AST Tag list”
and “Available Tag” list:
AAM Builder allows user to edit user-defined AST following the steps below, with “Edit” function
tool:
Step 2: Click “Edit” button to pop up the “Edit AST” dialogue box. Update all AST necessary
information.
Note: Master AST is system-defined and not editable. If Master AST is selected and click
“Edit” button, an error message will display as below:
Note: To update Tag information, please refer to the section Create a User-Defined AST
for details.
Step 3: Click “OK” to proceed and the selected AST editing is completed.
To create a new user-defined AST, AAM Builder also allow users to use “Copy” function as
described below:
Step 2: Click “Copy” button to pop up a “Copy AST” dialogue box as below. Enter reasons in
“Reason” area.
Note: “Reason” area must be filled and can not be left blank.
Note: Master AST can not be copied. If Master AST has been selected and click a “Copy”
button , an error message will be prompted as below:
Step 3: Click “OK” to proceed and a new AST has been created which is copied from an existing
AST with identical Tag list.
Step 4: To edit the newly created AST by using “Copy” tool, refer to section “Edit a user-
defined AST” described before.
Step 2: Click “Delete” button and a “Delete AST” dialogue box will appear as below. Enter
reason for the deletion in “Reason” Area.
Note: “Reason” area must be filled and can not be left blank.
Note: Master AST can not be deleted. If Master AST has been selected and click “Delete”
button, an error message will be displayed as below:
Step 3: Click “OK” to proceed with the deletion of selected AST. The selected AST is deleted.
With AAM Enforcer, each tag alarm setting can be viewed and edited. Guiding steps are details
below:
Step 1: Under “AST Builder”, select Area using “AST Selector”, and AST from the AST list. All tags
assigned to the AST (including both master AST and user-defined AST) will be displayed in the
AST Viewer Area.
Step 2: Check the “Check/Uncheck” box to select tags, or use “Unit” or “Tag” filter as
below to select tags to view alarm settings.
Step 3: Click “Show Alarm Settings” button and “Alarm Setting Display”
window will display as below and contains information including:
• Area;
• Unit;
• Equipment ID;
• Source Doc;
• Tag Name;
• Tag Comment;
• Safety Critical Classifications;
• Maintenance Record;
• Alarms limits including SH, SL, HH, LL, PH, PL, DL, VL;
• Additional alarm message including Engineering unit, Alarm priority, highest
computed priority, MOC#, Alarm inhibition status;
• Other advisory messages including Purpose of the limit setting, severity of the
consequences associated with the alarm, response speed required for corrective
action to be performed and to have desired effect, etc.
Please refer to Key Concepts and Terminologies for details on the above information used
in this document.
Note: Alarm setting is not editable with “Show Alarm Settings” function.
Note: If more than one (1) tag have been selected to view alarm setting, user can click
“Pre” or “Next” to view the alarm setting of previous or next tag.
Step 1: Under “AST Builder”, select Area using “AST Selector”, and AST from the AST list. All tags
assigned to the AST (including both master AST and user-defined AST) will be displayed in the
AST Viewer Area.
Step 2: Check the “Check/Uncheck” box to select tags, or use “Unit” or “Tag” filter to select tags to
view alarm settings.
Step 3: Click “Edit Alarm Settings” button and “Alarm Setting Editor” window
will display as below with same information as displayed by “Show Alarm Settings”.
Note: If more than one (1) tag have been selected to view alarm setting, user can click
“Pre” or “Next” to view the alarm setting of previous or next tag.
Note: The information field displayed by “Alarm Setting Editor” window may have two
types of backgrounds, light green colored or white colored.
Light green colored fields are not editable.
White colored fields are editable.
Update alarm setting if required. However, not all fields are editable. Below is a list for
editing reference
• Computed priority: Not editable. Computed based on severity and response speed
factors.
Note: After selecting Severity and Response Speed from respective dropdown list
as below, Computed Priority will automatically determined by AAM based on the
above table “Computed Priority of Alarm”.
Please refer to Key Concepts and Terminologies for details on the above information used
in this document.
Note: To view alarm setting editing history, go to Builder\AAM Enforcer\Audit Trail Viewing.
Step 5: Click “Close” button if all tag alarm setting have been updated. “Undo” and
“Save” button will appear on the right-bottom corner of the “Alarm Setting Editor”.
Note: To ignore the edited alarm setting, click “Undo” button to exit.
Step 5: Click “Save” button to proceed. A “Save Alarm Setting” dialogue box will appear. Enter
“MOC Ref” and “Reason” for this editing.
Step 6: Click “OK” button to proceed to save the updated alarm setting. Or click “Cancel” to exit.
The updated Tag alarm setting is reflected in the “AST Viewer” area as below.
AAM allows user to Remember Last MOC# Used and Remember Last Reason Given when
executing “Save Alarm Setting” as mentioned in Step 5 above.
This feature will automatically display the last MOC# used and Reason Given in the respective
“MOC #” area and “Reason” area.
AAM Builder user can either enable or disable these two settings.
AAM allows user to take following Actions for all tags assigned to a specific user-defined AST,
including:
• Set All Tags to “Alarm Enabled”: This is to enable ALL AST tags “Alarm on/off Setting” to
“Alarm Enabled” mode. Steps are as below:
o Click “Set All Tags to “Alarm Enabled” “ tab, a “Save Alarm Setting” dialogue box
will popup as below:
Note: The new settings only apply to all tags assigned to the selected AST.
• Set All Tags to “Alarm Disabled”: This is to enable ALL AST tags “Alarm on/off Setting” to
“Alarm Disabled” mode. Steps are as below:
o Click “Select All Tags to “Alarm Disabled” to pop up a “Save Alarm Setting”
dialogue box.
Note: The new settings only apply to all tags assigned to the selected AST.
IM 052006-A01 2ND EDITION ISSUE 22 MAY 2006 PAGE - 67
AAM MANUAL BUILDER R100
• Import Alarm Settings: This is to allow Alarm setting in CSV format to be imported to AAM
alarm data base, instead of using “Editing Alarm Setting” function for Alarm Setting editing.
Steps are as below:
o Click “Import Alarm Setting” to pop up a “Import Alarm Settings” dialogue box.
• Export Alarm Settings: This is to allow Alarm setting in CSV format to be exported for other
usages, et, alarm setting editing. Steps are as below:
o Click “Export Alarm Settings” to pop up a “Export Alarm Setting” dialogue box.
Tag Monitor function allows AAM Builder user to monitor additional tags or changes made to tags,
take necessary steps to update AAM alarm data base.
The figure below summarizes the screen flow and key functionalities of Tag Monitor by using tab
from menu bar, or press the “Tag Monitor” icon. The tag monitor screen is illustrated as below:
The screen consists of two parts, one is “New Tag” Window in the left column, and the right colun
is for “Changed Tags”.
1. Use “OPC Server” selector to view new tag(s) from specific OPC Server, as illustrated
below:
Select a new tag, by clicking on one of the selection boxes at the left side of “New
Tags” data grid.
Click on “Read” button to pop-up the “New Tag” dialog box showing the actual tag
information read from DCS. If the AAM is not able to read the values of the changed
tag, it is probably deleted.
If no tag, or more than one tag, is selected when “Read” button is clicked, the following
dialog box will be displayed:
Select a new tag, by clicking on one of the selection boxes at the left side of “New
Tags” data grid.
Click on “Upload” button to pop-up the “Uploading New Tag” dialog box showing the
actual tag information read from DCS, and pausing for a confirmation.
Click on “Confirm” button to proceed to upload this tag into “Upload Area” of the
selected OPC Server. An uploaded tag will appear in the “Upload Area” in “Tag
Hierarchy” screen.
If no tag, or more than one tag, is selected when “Upload” button is clicked, the
following dialog box will be displayed:
Select a new tag, by clicking on one of the selection boxes at the left side of “New
Tags” data grid.
Click on “Ignore” button to pop-up the “Delete One Tag” dialog box showing the actual
tag information read from DCS, and pausing for a confirmation.
Click on “Confirm” button to proceed to delete this tag from “Tags to be confirmed”
data grid. The deleted tag and its subsequent events will not be displayed.
If no tag, or more than one tag, is selected when “Upload” button is clicked, the
following dialog box will be displayed:
Select a to-be-confirmed tag, by clicking on one of the selection boxes at the left side
of “Tags to be confirmed” data grid.
Click on “Read” button to pop-up the “Tag Changed” dialog box showing the actual tag
information read from DCS. If the AAM is not able to read the values of the changed
tag, it is probably deleted.
If no tag, or more than one tag, is selected when “Read” button is clicked, the following
dialog box will be displayed:
Select a to-be-confirmed tag, by clicking on one of the selection boxes at the left side
of “Tags to be confirmed” data grid.
Click on “Update” button to pop-up the “Changed Tag” dialog box showing the actual
tag information read from DCS, and pausing for a confirmation.
Click on “Update Value” button to proceed to update this tag information into the
database.
If no tag, or more than one tag, is selected when “Upload” button is clicked, the
following dialog box will be displayed:
Select a to-be-confirmed tag, by clicking on one of the selection boxes at the left side
of “Tags to be confirmed” data grid.
Click on “Ignore” button to pop-up the “Delete One Tag” dialog box showing the actual
tag information read from DCS, and pausing for a confirmation.
Click on “Confirm” button to proceed to delete this tag from “Tags to be confirmed”
data grid. The deleted tag and its subsequent events will not be displayed.
If no tag, or more than one tag, is selected when “Upload” button is clicked, the
following dialog box will be displayed:
4.4.3 Shift/Enforcement PC
Enforcement Application by AAM software is to enforce alarm settings from implemented alarm
database to DCS settings. This configuration is on a per AAM Client PC basis (each of which can
have an area of responsibility based on plant hierarchy) and the enforcement can be made at a
pre-set time or shift.
Shift can be configured based on the actual plant operation. To edit, follow the steps below:
click “Edit” button . A “Shift Configurator” dialogue box will display as below:
• Update shift information as requested. Click “OK” to proceed with shift configuration, or
click “Cancel” to abort the configuration.
• Upon clicking “OK” button, the shift details will be updated as below:
AAM allows enforcement configuration to be edited, created, and deleted. These buttons can be
found in the Enforcement Configuration window area.
• Add Enforcement PC
Click “OK” button to proceed. Click “Cancel” button to abort the addition of an
enforcement PC.
Existing enforcement PC can be re-configured using Edit function. Following the steps below
to edit the enforcement PC:
o Click “Edit” button . A “Edit Enforcement PC” window will display as below.
o Click “OK” button to proceed with editing, or click “Cancel” to cancel editing.
o Editing completed if “OK” is clicked. The edited information will be updated in the
“Enforcement Configuration” window as below:
• Delete An Enforcement PC
o Select a PC to be deleted.
o Click “OK” to proceed, or click “Cancel” to abort deletion of the selected PC.
o The selected enforcement PC will be deleted if “OK” is clicked in the previous step.
The “Enforcement Configuration” window will be updated as below:
Audit Trail Viewing function allows AAM Builder user to view audit and trial all modifications made
to alarm documentation.
The figure below summarizes the key functionalities of Audit Trail Viewing.
Step 1: Logon to AAM Builder as user with AAM Builder access rights. AAM Enforce\Audit Trail
Viewing window can be displayed by using Audit Trail Viewing panel toolbar as below
or by clicking action bar in side bar area, or by clicking “Audit Trail Viewing” icon
.
o Upon clicking “To”, a calendar will appear for user to choose a date.
User can also use the filter provided as below to make report filtration.
User name and/or Details can be entered in “User” area or “Details” area. Click button to
retrieve audit report and a report window will display as below:
AAM Builder software has the following functions for AAM Report module:
• Configuration:
o System Default Parameters
o AAM Priority
o KPI Target
• On-demand Request
4.5.1 Configuration
AAM Report Configuration allows AAM Builder user to manage system default parameters, AAM
priority, and KPI target. Key functions are summarized as below:
Below is the list of system default parameter and respective values, units, and descriptions.
The values entered as shown above will serve as default parameters for generating the Monthly
KPI Report. They will also be used when no value or inappropriate values are entered by the user
on the web interfaces.
The system default parameters can also be edited if necessary. To edit, select the parameters to
be edited, click “Edit” button . A “System Default Parameters” window will be displayed as
below:
Default value will be shown with blue background. To change, enter the new value in “Value” area.
Click “Ok” button to proceed with the value change. Or click “Cancel” to abort the editing.
DCS Tag Priority can be mapped to user defined AHR Alarm Priority. A DCS Tag Priority\AHR
Alarm window is displayed as below:
IM 052006-A01 2ND EDITION ISSUE 22 MAY 2006 PAGE - 84
AAM MANUAL BUILDER R100
To edit the Alarm Priority Mapping, select the Priority to be edited. Click “Edit” button and a
Alarm Priority Mapping window will display as below:
Enter new AAM Alarm Priority level to be assigned the corresponding DCS Tag Priority, click “OK”
button to proceed. Or click “Cancel” to terminating the priority editing.
Upon clicking “OK” button, the new AHR Alarm Priority setting will be updated and displayed as
below.
KPI Target can be set and edited with AAM Report, as shown below:
The value entered above will be displayed as KPI targets on the Monthly KPI Report.
To edit KPI Target value, select the KPI to be edited, click “Edit” button . A KPI Target window
will display as below:
Default value will be shown with blue background. To change, enter the new value in “Value” area.
Click “Ok” button to proceed with the value change. Or click “Cancel” to abort the editing.
Upon clicking “OK” button, the new KPI Target setting will be updated and displayed as below.
On-demand request allows user to manage on-demand/manual A&E (based on DA reads) for
AOFs, “alarm state changes” and “PID mode changes”.
Click “on-demand request” from side bar (function tree) or from main menu. A “AAM Builder”
dialogue box will be displayed as below:
As shown in the dialogue box, on-demand request can take a lot of minutes to process.
Click “cancel” to abort this request. Or click “Ok” to proceed, a “On-demand request” dialogue box
will be displayed as below:
Select OPC Server name from OPC server field dropdown list, and enter “delay per tag” value.
Click “cancel” to abort the request, or proceed with the request by clicking “OK”. AAM start to
reach data from DCS.