Annual Technical Quiz Nov 7, 2014
Annual Technical Quiz Nov 7, 2014
2014
Branch : Surat
What is the minimum impact test temperature of 20 mm thk SA 516 Gr 70 plate asper SA20
A vertical 10 inch pipe has to join with a 8 inch pipe on top . Both the pipe axis need to be same .
For inter connection you need
A flange is getting welded to a pipe . Flange ID and Pipe ID are same. The flange has to be a
A) Rougher B) Smoother
5 A
Surface waviness height will be bigger in rough surface
Following cannot be corrected susequently in weld seam without cutting the seam
Which of the following heat treatment calls for cooling in still air after soaking?
10 B
A) Heat treatment time B) Soaking time C) Heating time
10 B
Soaking time is the time required to maintain at particular temperature
Tempering temperature is
Tempering temperature is to decrease hardness which is increased in earlier heat treatment i.e. Normalizing or Quenching
Test piece in bend has failed .It indicates that the material is
316 has more UTS than 304L at room temperature . This is because of
A) Mo B) Carbon C) Ni
14 B
Less carbon percentage will increase the tensile property.
15 C
TC 1) Acceptable B) Not acceptable C) Not acceptable RA not reported
15 C
RA is must to be reported
A) Manufacture of steel .
B) Seperation of iron from iron ore.
17 C) Refining of iron . B
Normal Carbon steel has about 98% iron and stainless steel 304 has about 72% iron . MT can be done on CS but not on
SS, because
A) The size of defect. B) The density of the film. C) The amount of film contrast.
D) The quality of the radiographic technique
26 D
We ensure minimum required dia of Wire using Penetrameter in Radiography to ensure sensitivity and quality of radiograph
A) Between the screen and film B) On the film side of object C) On the source side of object D)
27 C
Source side of the object will tend to produce lesser sensitivity
A) MT B) UT C) PT D) RT
28 D
RT can clearly produce Porosity, PT and MT are for surface only and not for sub surface. UT can not detect it fully.
Low tempersture impact test specimen should be soaked in liquid coolant for
Pendulam of impact test machine should be should be impact tested within ---------
minutes of removing the low temperature impact test specimen from coolant pot.
A) 10 B) 15 C) 2 D) 5
30 C
Time for Imact testing should be minimum after removing from Coolant pot to avoid Increase in Temperature of Specimen
The following hardness testing method do not call for measuring indentation size .
Following test is carried out to confirm and accept solution annealing in stainless steel
A) Test as per ASTM A 262 Pr A B ) Micro test C) Macro test D) Bend test
32 A
This method will check IGC so that solution annealing can be ensured / Verified
Standard rectangular and circular Tensile Test pieces center thickness or center diameter shall be measured to the accuracy of
In Tensile Test, fracture takes place outside the middle half of the gauge length, but within reduced section, % of elongation
observed will be treated as :
A) More B) Less
36 B
Less carbon will produce good weldability, Also other element like Ni, Mo will produce good weldability if less in material.
Can a welder who had qualified in SS pipe using GTAW , weld CS pipe ?
A) Yes B) No
38 A
State P no , F no and A no for welding carbon steel plate using E 7018 electrode
A) material for low temperature service. B) FRP material. C)material for high temperature service.
41 A
We should use low stress stamp on Both A and C type of material. However Type A seems more critical.
When conducting random sampling inspection the inspector should ensure that -
A) 100% quantity is available for inspection. B) vendor has completed inspection on 100% quantity.
C) Internal inspection report for 100% quantity is available. D) all of the above.
42 D
Required as per procedure
Confidentiality means -
Independence means -
Impartiality means -
49 D
A) it is not signed.
B) does not have a conclusion.
49 D
C) does not bear the TUV logo.
D) all of the above.
All information and things mentioned above is required since format is finalized.
Calibration status of testing & measuring equipment should be verified -
Calibration is required to ensure before inspection and to ensure any change during inspection