SG High Integrity Pressure Protection System PDF
SG High Integrity Pressure Protection System PDF
SG High Integrity Pressure Protection System PDF
FOLD
FOLD
Contents
Introduction 01
Benefits of HIPPS 02
Delivery Wheel 03
HIPPS 06
FOLD
FOLD
FOLD
FOLD
Benefits of HIPPS
Severn Glocon Group integrated HIPPS are designed to set a new
standard in safety, performance, assembly and test of high integrity
pressure protection systems, enabling oil and gas operators to:
FOLD
FOLD
Delivery Wheel
The Severn Glocon Group fully satisfy HIPPS requirements by ensuring
that the level of safety, quality and service is delivered at all levels.
The Severn Glocon Group HIPPS facility enables Integrated Factory Acceptance Test (IFAT)
bringing together the HIPPS components and customer and Classification Society in a
single space for validation and testing of the HIPPS.
FOLD
How does HIPPS work
HIPPS is an application-specific safety system to prevent over
pressurisation of a pipeline by rapidly closing the final elements
to shut off the pipeline.
03 02
COMMS LINK LOGIC SOLVER
SOLENOIDS 04
05 FINAL ELEMENTS 05
04 SOLENOIDS
01 01 01
PRESSURE TRANSMITTERS
Final Element to perform the action needed to isolate the high-pressure zone,
allowing a safe shutdown. The final elements, valves and actuators, have proven
track record in critical safety systems.
GAS OUT
PT PT PT
UPSTREAM
LIQUID OUT
In addition to the Electronic HIPPS’s pressure transmitters, the Mechanical HIPPS uses
mechanical initiators to detect an increase in pressure (pressure sensors,
PS), providing an additional level of protection in the event of over pressurization.
Two pairs of pressure sensors are linked to two final elements in series. Each final element
has mechanical initiators with ‘one out of two’ (1oo2) voting. This standalone system has
no external power requirements.
PT PT PT PS PS PS PS
UPSTREAM
INITIATORS INITIATORS
FINAL ELEMENTS eHIPPS hHIPPS
FULLY RATED DERATED
The Subsea HIPPS combines the benefit of both Benefits of electrical and mechanical HIPPS include
electronic and mechanical activation. The additional Combined electronic and mechanical pressure protection
pressure protection offered by mechanical HIPPS
comprises two pipeline isolation valves, each Independent operation
controlled by two independent hydraulic control Simple operation of mechanical HIPPS
sub-systems. The valves are arranged in series
within the pipeline, with each valve capable of Partial and full stroke testing
independently isolating the flow when closed.
W3 W2 W1
CA C = Consequence parameter
A 0 0 CA = Minor injury
CB = Serious injury to one or more, death to one
CC = Death to several people
1 A 0 CD = Very many people killed
PA
PB F = Frequency of exposure parameter
CB FA
2 1 A FA = Rare to more often exposure
START FB PA FB = Frequently to continuously
CC FA PB
3 2 1 P = Possibility of escape
FB PA PA = Possible under certain conditions
CD PB = Almost impossible
FA PB
4 3 2
FB PA W = Likelihood of event
W1 = a relatively slight probability
PB W2= a relatively medium probability
B 4 3 W3= a relatively high probability
Safety
Combined electronic and mechanical HIPPS provides Integrated design, assembly and test – the Severn
an additional level of redundancy, and safety, due to the Glocon Group fully understands the importance of
variance between the pressure detection parts used. the architectural constraints of IEC 61508, which
is a non-prescriptive performance based standard
HIPPS closure time customised to reflect actual rather for functional safety systems but not specific to
than theoretical requirements – the industry reference a 2
the Oil and Gas Industry, and IEC 61511 which is
second closure, however, this may jeopardies other parts
more relevant to the Oil and Gas Industry.
of the process (the actual required closure time needs to
be qualified). It is imperative that required speed of closure
for the final elements is calculated based on the protected
volume, correct speed of operation is critical to ensure a
surge is not created, compounding the initial problem.
FOLD
FOLD
The IEC 61508 standard defines four levels of SILs: SIL 1 being the lowest and SIL 4 the highest. A SIL
is determined based on a number of quantitative factors, in combination with qualitative factors such as
development process and safety life cycle management. In effect, defining the degree of redundancy required.
Operational
Isolation valves maintained in-line, avoiding the cost
and disruption of removing the valve during process
maintenance. In addition, the valve design permits
the pipeline to be pig inspected.
FOLD
FOLD
06
05
02
04
07 03
01
08
20
21
19
09
15 16
14
13 17
12
11
10
18
01 Severn Glocon Group plc 04 Severn Unival 10 Severn Glocon 16 Severn Glocon India
Gloucester England UK Widnes England UK Rio Brazil Chennai India
Mars Valve UK 05 Severn Ball Valves 11 Severn Valve Solutions 17 Severn Glocon
Gloucester England UK Aberdeen Scotland UK Basra Iraq Kuala Lumpur Malaysia
L.B.Bentley 06 Severn Norway 12 Severn Glocon 18 Severn Glocon Australia
Stroud England UK Bergen Norway Saudi Arabia Perth Australia
Ionex SG 07 Severn Glocon Atlantic Canada 13 Severn Glocon 19 Severn Glocon
Nailsworth England UK Newfoundland Canada Doha Qatar Beijing China
02 Severn Unival 08 Severn Glocon 14 QTRCO SG 20 Severn Glocon
Brighouse England UK Calgary Canada Dubai Seoul Korea
03 Severn Subsea Technologies 09 Severn Glocon 15 Severn Glocon FZE 21 Severn Glocon
Redruth England UK Houston Texas USA Dubai Tokyo Japan
T. +44 (0)845 223 2040 F. +44 (0)845 223 2041 sales@severnglocon.co.uk www.severnglocon.com