Professional Documents
Culture Documents
Wire Rope
Wire Rope
S
WI
O
.
td
Rope Outer Sectional Breaking load (Reference)
diameter wire area Rough calculation
Galvanized Bright • Galvanized Bright
.L
diameter Unit mass
.K
3.15 0.35 4.10 5.24 { 0.53 } 5.90 { 0.60 } 6.45 { 0.66 } 6.81 {0.69} 0.037
4 0.44 6.57 8.45 { 0.86 } 9.52 { 0.97 } 10.4 { 1.06 } 11.0 {1.12} 0.059
lH
5 0.56 10.3 13.2 { 1.35 } 14.9 { 1.52 } 16.2 { 1.66 } 17.1 {1.75} 0.093
6.3 0.70 16.3 21.0 { 2.14 } 23.6 { 2.41 } 25.8 { 2.63 } 27.2 {2.78} 0.147
8 0.88 26.0 33.8 { 3.45 } 38.1 { 3.88 } 41.6 { 4.24 } 43.9 {4.48} 0.237
9
10
11.2
1.00
1.10
1.24
33.3
41.1
51.5
42.8
52.8
66.2
{ 4.36 }
{ 5.38 }
{ 6.75}
48.2
59.5
74.6
{ 4.91
{ 6.06
{ 7.61
}
}
}
na
52.6
65.0
81.5
{ 5.37
{ 6.62
{ 8.31
}
}
}
55.6
68.6
86.0
{5.67}
{6.99}
{8.77}
0.300
0.371
0.465
io
12.5 1.39 65.2 82.5 { 8.41 } 92.9 { 9.48 } 102 { 10.4 } 107 {10.9} 0.580
14 1.56 81.6 103 { 10.6 } 117 { 11.9 } 127 { 13.0 } 134 {13.7} 0.727
at
16 1.78 105 135 { 13.8 } 152 { 15.5 } 166 { 17.0 } 176 {17.9} 0.950
18 2.00 133 171 { 17.4 } 193 { 19.6 } 211 { 21.5 } 222 {22.7} 1.20
rn
20 2.20 164 211 { 21.5 } 238 { 24.3 } 260 { 26.5 } 274 {28.0} 1.48
22.4 2.48 206 265 { 27.0 } 298 { 30.4 } 326 { 33.2 } 344 {35.1} 1.86
(24) (2.66) (237) (304) {31.0 } (343) { 34.9 } (374) { 38.2 } (395) {40.3} (2.14)
te
25 2.78 259 330 { 33.6 } 372 { 37.9 } 406 { 41.4 } 429 {43.7} 2.32
In
(26) (2.86) (273) (357) {36.4 } (402) { 41.0 } (439) { 44.8 } (464) {47.3} (2.51)
28 3.12 327 414 { 42.2 } 466 { 47.5 } 509 { 51.9 } 538 {54.8} 2.91
30 3.30 370 475 { 48.4 } 535 { 54.6 } 585 { 59.6 } – – 3.34
ee
31.5 3.50 410 524 { 53.4 } 590 { 60.2 } 645 { 65.7 } – – 3.68
33.5 3.70 461 592 { 60.4 } 667 { 68.1 } 729 {74.3 } – – 4.16
K
35.5 3.93 517 665 { 67.8 } 749 { 76.4 } 819 {83.5 } – – 4.67
37.5 4.16 577 742 { 75.7 } 836 {85.3 } 914 {93.2 } – – 5.22
40 4.40 657 845 { 86.1 } 952 {97.0 } 1040 {106 } – – 5.93
ak
M
(Remarks) 1. Dash (–) marks represent those that can be made on request.
2. Please refer to Page 46 (Tough Rope) if a higher breaking load is required.
3. Rope diameters in parentheses ( ) may be discontinued in the future and so those not in parentheses are recommended.
4. The figures shown in bold in this chart denote JIS values.
12