Masterseal 720: General Purpose Polysulphide Joint Sealant

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

MasterSeal® 720 (Formerly known as Masterflex® 720)

General purpose polysulphide joint sealant

DESCRIPTION APPLICATION DIRECTIONS


A two component sealing compound based on Joint Design: The minimum width and depth of a
polysulphide polymers blended with fillers and joint should be 6 by 6 mm. Horizontal expansion
chemical curing agents, which cure after mixing to joints, where possible, should be at least 12 mm
form a durable rubber like seal. and not more than 25 mm deep. The depth of the
joint should never exceed its width. Except in the
ADVANTAGES case of water retaining structures and where shear
movement is anticipated the ratio of width to depth
This sealant is highly elastic and is able to withstand
of 2:1 should if possible be maintained. This ratio
continuous extension and recovery. It may be used
provides the optimum geometry to allow movement
with most common building materials such as
to occur within the joint without placing excessive
concrete, plaster, brick and stone. It exhibits
force on the joint faces. Joint faces should be
superior resistance to many common chemicals fuel
parallel and the joint width should be at least four
oils and solvents, ultra violet light and ozone,
times the maximum anticipated movement. When
making it suitable for exterior use, and for use
placing the sealant the joint opening should be
where the sealant is subjected to contact with
central to its maximum compression/expansion
chemicals solvents and oils.
cycle.

MasterSeal® 720 complies with selected


Surface Preparation: The correct preparation of
requirements of SABS 110.
the joint faces is absolutely essential to the
satisfactory performance of the sealant. All surfaces
TYPICAL USES
should be dry and sound and laitance or surface
To form a long lasting water and weatherproof seal contamination should be removed by thorough wire
in both horizontal and vertical moving joints and brushing, grinding or grit blasting. Vacuum or blow
joints which are subject to continuous cyclic with compressed air to ensure thorough removal of
movement. dust. Metal surfaces should be free of mill scale and
rust and mild steel treated with a suitable
Typical applications include joints in curtain walls, anticorrosive primer.
floor and wall expansion joints, between precast
units. MasterSeal® 720 is NOT recommended for Bond breaker: To ensure proper movement of the
use as a joint sealant in industrial flooring joint a bond breaker must be used at the base of the
applications subject to wheeled traffic. In these joint. Where a backing material such as
instances use MasterSeal® 310 / 320 / 480 polyethylene foam rod is used to ensure the correct
depending upon requirements of the floor and joint geometry a bond breaking tape is not required.
expected traffic. For water retaining structures care must be taken to
comply with the design requirements.
MasterSeal® 720 (Formerly known as Masterflex® 720)

Priming: Prime surfaces with MasterSeal® P 101. CLEANING


This is a twin pack epoxy primer. Mix base and
Clean all tools and equipment with solvent ie MEK.
activator thoroughly and apply the mixed material
with a brush to the joint faces ensuring complete before setting of the sealant has taken place.
coverage. Particular attention should be paid to any
voids and hollows. Allow at least 30 min. for the MATERIAL USAGE ESTIMATING GUIDE
solvent to evaporate and apply the sealant. After
(NO ALLOWANCE MADE FOR WASTAGE)
approximately 3 hours or once the primer has lost
its tack, re-prime. Protect the primed surface from
dust and dirt, which could coat it and interfere with JOINT WIDTH mm
the adhesion of the sealant. 6 12 20 25 30 40

JOINT DEPTH mm
6 55.5 27.8 16.7 13.3 11.1 8.4
MIXING
MasterSeal® 720 is supplied in a 2l kit. The activator 12 27.8 13.9 8.4 6.7 5.5 4.2
is packaged in a plastic bag that rests on top of the 20 16.7 8.4 5.1 4 3.4 2.5
sealant base separated from it by a plastic sheet.
25 13.3 6.7 4 3.2 2.7 2
Remove the plastic separating sheet, transfer the
total quantity of activator onto the base component 40 11.1 5.5 3.4 2.7 2.2 1.7
and mix thoroughly using a slow speed electric drill
fitted with a flat blade stirrer. Scrape down the sides Approx. length of Joint in metres/2.0ℓ unit
of the can and the base and remix until the colour is
uniform and free from streaks. Thorough mixing is PROPERTIES
essential and should take 5 to 10 minutes.
Mixing Ratio Do not split kits
3
Density 1.49g/cm
APPLICATION O
Pot life (at 25 C) >45 Minutes
O
Fill the sealant into a closed barrel gun using a Application Temperature 5-35 C
O O
Service temperature -25 Cto +90 C
follow plate or small trowel. Gun the sealant into the Hardness ±15 Shore A
joint using a continuous squeezing of the trigger to Movement Accommodation 30%
Tack free 2 days
ensure a smooth continuous flow of material. Fill the
Full cure 7 days
joint from the bottom up and ensure that there is Chemical resistance Most dilutedChemical,
contact between the sealant and joint surfaces. To fuel Oils and solvents

assist in removing air bubbles and ensure contact of


the sealant with the walls of the joint the sealant STORAGE
should be tooled to a smooth finish using a rounded Store under cover, out of direct sunlight and protect
spatula. A soapy solution may be used to aid the from extremes of temperatures. Failure to comply
process. Remove any masking tape applied before with the recommended storage conditions may
cure has commenced. result in premature deterioration of the product or
packaging. For specific storage advice consult
BASF Construction Chemicals SA’s Technical
Services Department.
MasterSeal® 720 (Formerly known as Masterflex® 720)

SAFETY PRECAUTIONS NOTE


As with all chemical products, care should be taken Field service, where provided, does not constitute
during use and storage to avoid contact with eyes supervisory responsibility. For additional
information contact your local BASF representative.
mouth, skin and foodstuffs (which can also be
tainted with vapour until product fully cured or BASF reserves the right to have the true cause of
dried). Treat splashes to eyes and skin any difficulty determined by accepted test methods.
immediately. If accidentally ingested, seek
immediate medical attention. Keep away from QUALITY AND CARE
children and animals. Place bags in containers, All products originating from BASF Construction
reseal containers and dispose of according to local Chemicals South Africa are manufactured under a
regulations. management system independently certified to
conform to the requirements of the quality,
environmental and occupational health & safety
standards ISO 9001, 2008.

* Properties listed are based on laboratory controlled tests.

® = Registered trademark of the BASF-Group in many countries.

The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by
NOTE BASF either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals South Africa (Pty) Ltd


852 Sixteenth Road, Midrand
PO Box 2803, Halfway House, 1685
Tel: +27 11 203 2405 Fax: +27 11 203 2679
www.master-builders-solutions.basf.co.za

You might also like