Compressed Air leakage Detail

Turbine Area
 Air leakage(passing) found in drain valves of Air receiver tank (Air compressor-2C and Air
compressor-2D)
Mill Area
 No major air leakage is found.
Boiler Area
 U-1-Heavy air leakage found at igniter of corner AB-4 and CD-3 .
 U-2-Heavy air leakage found at igniter of corner AB-3.
 Heavy air leakage found at all drain lines(total 8 no.) of Igniter Cooling line in both units.
Observation:
 Air compressors are not running in full load condition (full load current 180A appro.)

Air compressor loading detail:

U-1 Air Air Compressor Air compressor Air compressor


compressor-A B
C D

Air compressor 152A 150A 144A 142A


loading

U-2 Air Air Compressor Air compressor Air compressor


compressor-A B
C D

Air compressor 165A 153A Ammeter Not 158A


loading working

*W/R raised for Air compressor-2C as ammeter not working.