P750 Portable Power Supply

Instruction Manual

Packing List

Host x1 Charger x1 Manualx1 TYPE C Data transfer cable x1

(optional) (optional) (optional)


Solar panel x1 3 W LED bulb x2 Car charger x1
1.After open the package, please check the included accessories. If
you find that the parts are missing or damaged, please do not start
and report it directly to the company and the dealer.
2. Do not take any action on this product until you have read the rest
of this manual.

Content
Product description
Product structure diagram
LED screen guide 3

Product parameters
Charging methods
How to use solar panel to charge
How to use the mains supply to charge
How to use the car to charge
Charging time
Instructions
How to use P750 to provide AC power
How to use P750 to provide DC power
Working hours

BMS management system (7 kinds of protection)


Precautions
The environment of disable
After-sales service
Product Description LED Screen Guide
P750 product is a safe, portable, stable, environmentally friendly small
energy storage system. The P750 can provide you with a very portable, Charging Battery Discharge
sustainable green energy solution for activities such as wild camping, status status status
outdoor aerial photography, expedition and search and rescue. Temperature
P750 has a rich output interface, it supply AC output port interface for warning
refrigerators, fans, projectors, computers and other equipment power Failure mode AC output voltage
supply; it provide USB TYPE-A and USB TYPE-C for mobile terminal
power, as well as supply 12V output interface for the LED lighting Input/Output power
Battery
equipment Power. P750 can support a variety of charging methods, can capacity
use the charger comes with the product, the optional solar panels and
the optional car charger for its charge.
In short, P750 design purpose is to think what customers think,and to
worry what the customers are worried about. USB USB DC12V AC
TYPE A TYPE C output output
Cigar lighter
output
Product structure diagram INPUT
Solar input, mains supply charge or car charging
1
Insert the charging icon when it is lit.

8
Battery
2
9 Battery remaining capacity icon
3
4 10
Full grid = battery full
5 11 Space = battery low
Raster flow = charge in progress
6 7 12 Battery remaining capacity SOC data display
When the temperature is too high or too low and reach the
① Handle ⑤ Power Master Switch ⑨ AC Output Port alarm data, it flicker. When the protection data is reached,
② LED Screen ⑥ 12V DC Output Port ⑩ AC Output Switch it is always bright.
③ USB TYPE A Output Port ⑦ Label   Charging Port
Fault warning
11
When P750 error occurred, disconnect the load and reset the
④ USB TYPE C Output Port ⑧ Vents   Cigar lighter output
12 power switch to resume power supply.

2 3
Output Parameters
Output When a load is detected, the discharge icon is lit .
Model P750
USB TYPE A Output When the USB device is detected, the USB TYPE A Capacity 750Wh
output icon of the LCD screen lights up
Solar panel charging Voltage:18V Current:<3.5A
USB TYPE C Output When the USB device is detected, the USB TYPE C
output icon of the LCD screen lights up Mains supply Charging Voltage:17V Current:5A

Car Charging Voltage:17V Current: Imax 2A


Cigar lighter output When the cigar lighter equipment is detected , the
cigar lighter output icon of the LCD screen is lit. Maximum continuous output power:300W
Output waveform: pure sine wave
12V output When the 12V output port is detected, the 12V output AC Output *1 Output voltage:
icon lights up AC 220V ±10% Output frequency:50Hz
AC 110V ±10% Output frequency:60Hz
AC output Click the AC output switch, turn on the AC output function, Output voltage range 11.2V ~ 16.8V,
AC output indicator light Cigarette lighter output*1
Output current range: 0A ~ 30A
110V output indication, indicating that the current device AC output Output voltage: DC12V ± 5%
voltage is 110V DC12V Output*2
Output maximum current (IMAX): 2A
220V output indication, indicating that the current device AC output Output Voltage:DC5V±5%
voltage is 220V USB TYPE A Output*3
Output maximum current (IMAX):2A
According to the agreement output 3.6V ~ 20V
Alarm function USB TYPE C Output*2
voltage, the maximum output current 3A
Overheating protection >65℃
No. Alarm Display alarm Reason Cooling method By wind

This icon remains blinking before Battery power less Over current protection, under voltage protection,
1 3 seconds apart
charging 20% of the charge than 10% Protection type over voltage protection, overload protection,
2 1 seconds apart Charge failure overheat protection, short circuit protection
This alarm icon remains blinking
3 2 seconds apart DC output fault Size L300*W170*H233 mm
before the fault is released
4 3 seconds apart AC output failure N.W. 7.44kg
This alarm icon flashes when the Operating temperature range -10℃--55℃
The temperature is
5 2 seconds apart alarm occurs and is always on
when under protection too high or too low
Storage temperature range 0℃--55℃

Enclosure rating Working state: IP30

*All technical features are tested at 25 °C

4 5
Charging methods

How to use solar panel to charge? How to use the car to charge
● Open the matching Solar Folding Bag which purchase from Garaye, (P750 not include The steps are as below:
solar panels), put it directly in the sun, connect the solar panels and P750 to charge.

● Use the solar panel (voltage 18V, maximum power 150W) to access the solar charging
interface,and placed it in the sun. Please pay attention to the positive and negative of
the solar charging interface.
Note: Please remove the solar panel or cut off the solar input after the battery is 100%
fully charged.

1 2

Step 1: Connect one end of the car charging cable to the product's car charging
connector.
1 2 Step 2: Connect the other end of the car charging cable to the car cigar lighter
interface, start the car, and then start charging.
Please unplug the Charging Cable after 100% fully charged.
How to use the mains supply to charge?
The steps are as below:

Charging Time
Charging way Estimated charging time(h)
Mains supply charging 10
Car charging 26
1 2 60W solar panel 15-30
Step 1: Plug one end of the adapter into the mains charging port and tighten it. 100W solar panel 9-16
Step 2: Insert the adapter plug into the mains supply socket, or access the mains supply 150W solar panel 7-12
network to start charging.
Please remove the charging cable after the battery is 100% fully charged. Please do not use the Note: The solar charging time varies depending on the weather environment.
outsourcing adapter to charge the product.

6 7
Instructions DC 12V output
The device has two DC 12V DC output,connect the
How to use P750 to provide alternating current? power interface which need the power supply to P750
1) Turn on the power switch; DC output interface , each output power is same (Please
2) Put the AC load device into the 220V AC output interface ,the load power can not check product specifications), two outputs can be used
exceed 300W; together, give the output more power. When the DC
discharge device is detected, the DC12V output icon of
3) Click the AC output switch to turn on the AC output function, the AC output icon on
the LCD screen is lit and the OUTPUT on the right side
the display Lit. Electrical equipment put into P 750 can be used normally.Click the
of the display is lit.
AC output switch again can turn off . The time between start the AC output interval
two times should no less than 5 seconds.
USB 5V output
4) Disconnect after use and turn off the main switch.
Connect one end of the USB cable to the USB output connector and the
other end to the corresponding phone or digital product for charging. P750
has three independent USB TYPE A output, each output current 2A, with 2
independent USB TYPE C output, according to the agreement output 3.6V ~
20V voltage, the maximum output current 3A. When the USB device is
detected, the USB output icon of the LCD screen is lit and the OUTPUT icon
on the right side of the display is lit.

How to use P750 to provide DC?


   

1) Turn on the power switch;


2) Put the DC load device into the corresponding DC output interface - the load
power can not exceed 100W;
3) Disconnect after use and turn off the main power switch.

You can use both AC and DC at same time, but please note that the load does not Working Time
exceed the upper limit.

Cigar lighter output


Insert cigar lighter into the device can be use.
When working, the LCD screen cigar lighter 12V 3W UAV PSP console Digital camera Smart phone
output icon lit, The OUTPUT icon on the right side lighting charge charge charge charge
of the display is lit. 230 hours + 10 times + 90 times + 160 times + 70 times +

32
Tablet PC Laptop
60W fan TV Mini Bar
charge charge
20 hours + 70 hours + 15 hours +
17 times + 8 times +

8 9
BMS management system (seven kinds of protection) 9. Non-professionals are not allowed to open the product and remove the parts--or else.
10. Due to the large output power of P750, under the output state, the larger load plug or
1. Over current protection: When the charging current is more than 10A, the discharge current short circuit may cause a slight spark, it is prohibited to use under flammable and explosive
is more than 35A, BMS will automatically turn off the charging circuit and discharge circuit to gas environment.
stop charging and discharging. 11, P750 AC output is the standard 220V sine wave voltage, it has potentially dangerous, can
2. Low voltage protection: When the monomer voltage is lower than 2.8V or total voltage be fatal, it must be treated with caution to prevent electric shock when using.
below 11.2V , The BMS will automatically turn off the discharge circuit, the user needs to 12, If not use the product for a long time, please turn off the power switch, regularly
(recommended for three months) to charge the device to prevent the aging of the internal
disconnect the load immediately, and then charge in time, or turn off the power switch.
battery.
3. Over voltage protection: When the monomer voltage is higher than 4.2V or the total voltage
is higher than 16.8V, BMS will automatically turn off the charging circuit, the user needs to Fault Resolution
disconnect the charger, and then turn off the power switch.
4. Overload protection: When the output power is too large, the output port voltage No. Fault Status Emergent Reasons Cause Analysis / Solution
automatically drops, can not discharge, please immediately disconnect the load, the output Under voltage protection Charge
back to normal. 1 Can not boot Load Exception Protection Disconnect the load and charge
5. Short-circuit protection: When the AC output or DC output have the short-circuit condition, Product damage Repair
BMS will automatically turn off the discharge circuit, immediately disconnect the load, turn off Charge over current protection Use a charger that complies with product specifications
the power switch, and then re-open the power switch to return to normal. Charger can not be
2 The charger is damaged Replace the charger
charged
6. Overheat protection: When the power supply temperature is higher than 65 ℃ or the
Charger is not working properly Charger power supply error or connection abnormality
inverter temperature is higher than 110 ℃, BMS will automatically turn off the discharge
Charge over current protection Using solar panels that meet product specifications
circuit, and disconnect the load immediately , turn off the power switch, and then re-open the
The charging current is too small The light is too weak
power switch and back to normal. 3
Solar panels can not
charge Solar panels damaged Replacement of solar panels
7. Low temperature protection: When the battery temperature is lower than -25℃, BMS
charge and discharge circuit is closed, do not charge and discharge to the equipment. The solar panel damage the work Wire harness connection exception

Battery under voltage protection charge


Precautions Discharge over current protection power equipment power is too high

Please read the following carefully before using this product, improper operation or the use 4 DC does not output Over temperature protection check the cooling system
of this product does not match with the electrical equipment will damage the product, also Harness quality is poor, harness
Drop for reliable quality wiring harness
pressure
damage the user's use of the relevant electrical equipment, check the power and voltage Product damage Repair
whether applicable to P750 before use.
Battery Under voltage Protection Increases battery voltage
1. Do not connect the charging connector to the DC12V discharge port, so as not to damage
Discharge over current protection Power equipment power is too high
the circuit; Do not connect the DC discharge device to the charging connector, so as not to 5 AC No Output
damage the circuit. Over temperature protection Check the cooling system

2. Charge according to the required voltage use the charger comes with P750 to charge, Product damage Repair
strictly prohibited to use the unrelated voltage for charging P750 or when charging artificially Load Exception Disconnect the load
to let output short-circuit. 6 Icon Always On Corresponding hardware failure To replace the corresponding hardware
3. It is strictly prohibited when using P750, let finger touch the metal which inside the output
The display is damaged Repair
socket, or artificial let output short circuit.
Load Exception Disconnect the load
4. It is strictly prohibited AC output and the main power grid connection.
7 Icon Exception Off Corresponding hardware failure To replace the corresponding hardware
5. It is strictly prohibited or immersed in water for P750. When not in use, should be kept in a
cool dry environment. The display is damaged Repair
The display does not
6. It is strictly prohibited to put P750 in the fire , heater or placed in high temperature heat 8
lit
The display is damaged Repair
source side when use and keep.
7. It is strictly prohibited to knock or throw the product. Note: If the above situation does not meet your situation or the problem can not be resolved,
8. It is strictly prohibited when using P750 in the strong electrostatic and strong magnetic please contact us, we will provide you help timely.
field , otherwise it is easy to damage P750 safety protection device and cause insecurity.
10 11
Environmental conditions

1. The product should be used in dry, clean and ventilated


environment.
2. To avoid direct sunlight, exposure, rain, moisture, dust, acid mist
environment.
3. It is strictly prohibited to using in the flammable, explosive gas
environment , beware of flame and sparks!
4. Ambient temperature -10 ℃ - 55 ℃.
5. The relative humidity of air is no more than 80% (25 ℃ ± 5 ℃).

After-sales service

This product provides 18 months free warranty period.

The following conditions are not covered by the warranty:


1. Exceed the warranty period.
2. Imitation or counterfeit products.
3. Imitate or fake brand logo and label.
4. Man-made damage (including broken, bruised, flooding, fire damage, etc.).
5. Improper use, resulting in a circuit breakdown or burn the phenomenon, the
PCB board due to short circuit burned.
6. If you do not plug in properly and burn out the connecting finger.
7. There is a lack of components.
8. Have been privately repaired.
9. Have moved the location of the component.
10 Due to high temperature baking and PCB board deformation.
11. Damage caused by force majeure.

For products that have been covered by the warranty period, our company can
provide paid maintenance service.

Disclaimer: The company reserves the right to change the product.