Professional Documents
Culture Documents
700-700i DCP v3.7 MN SW Release Notes 20111028
700-700i DCP v3.7 MN SW Release Notes 20111028
PURPOSE
This document is intended for use by Xerox CSE’s & Analysts only. Information
contained in this document is not intended for use by Xerox 700/700i DCP customers.
The 700/700i DCP V3.7MN System Software can be installed on any Xerox 700DCP
machines. This software release supports the HCF (High Capacity Feeder), IFM
(Interface Module), HCS (High Capacity Stacker), Advanced Finisher, Light Production
C Finisher, and TSF (Trimmer/Square Fold) features. This software also supports the
OHCF (Over size document High Capacity Feeder) option. This software also enables a
DFE connection for properly equipped machines and the scan ahead feature.
Version number
of the previous
Version Number Name of ROM image file
release software
set
Controller
XC:
・ PS V1.211.7 ESS.bin V1.211.4
IOT V54.58.0 IOT.bin V54.58.0
Interface Module V8.29.0 IFM.bin V8.29.0
High Capacity Stacker V2.4.1 HCS.bin V2.4.1
IISS V2.4.2 IISS.bin V2.4.2
DADF V12.3.0 PF1DADF.bin V12.3.0
Advanced/Prof. Finisher V17.20.0 CFIN.bin V17.20.0
Light Production C Finisher V5.12.0 DFIN.bin V5.12.0
HCF V6.0.3 EPROM V6.0.3
PF 3.2 (OHCF 2-tray) V3.33.0 HCF32.bin V3.33.0
OHCF V 3.17 or later EPROM V 3.17 or later
INSTALLATION
The installation of the software components is documented in a separate document titled
700/700i DCP V3.7MN System Software Download Procedure.
• This software is for any configuration XEROX 700DCP.
• All components described in the PURPOSE section must be installed as a set.
• All required NVM configuration changes associated with this release are defined in
that document.
1 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller - Product name is not correctly displayed on report/CWIS
IOT - None
IISS - None
DADF - None
C Finisher - None
D4 Finisher - None
IFM - None
HCS - None
PF3.2 HCF - None
Return to
default
Setting
Subsystem Chain Link value after
Value
Note
initializatio
n
Controller - - - - None
IOT See Changes below; You do not need to manually set up any
10/28/11 2
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
742 482 0 Invert Motor Startup Timing: Simplex Adjusted (Process Speed
101.896mm/s) 1Count=1ms
742 483 0 Invert Motor Startup Timing: Duplex Adjusted (Process Speed
101.896mm/s) 1Count=1ms
742 497 0 Invert Adjust the timing of acceleration (Tab) (Process Speed
101.896mm/s) 1Count=1ms
742 506 0 Invert Adjust the timing of acceleration (Tab Paper) (Process
742 688 488 Side Regi Adjusting the threshold to enable / disable control
742 689 488 Side Regi Adjusting the threshold to enable / disable control
742 698 488 Side Regi Adjusting the threshold to enable / disable control
742 699 488 Side Regi Adjusting the threshold to enable / disable control
300gsm/Dup Path)1Count=1mm
742 785 0 Small Lead Regi correction (221~256gsm/TA & Dup Path)
1Count=1mm
742 786 0 Small Lead Regi correction (257~300gsm/TA & Dup Path)
1Count=1mm
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
3 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller - None
IOT - None
IISS - None
DADF - None
C Finisher - None
D4 Finisher - None
IFM - None
HCS - None
PF3.2 HCF - None
Return to
default value Setting
Subsystem Chain Link
after Value
Note
initialization
Controller - - - - None
IOT None
IISS - - - - None
DADF - - - - None
C FIN - - - - None
D4 Fin - - - - None
IFM - - - - None
HCS - - - - None
PF3.2 HCF - - - - None
Detail of restrictions
10/28/11 4
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
Subsystem # Corrections.
Controller - None
IOT - None
IISS - None
DADF - None
C Finisher - None
D4 Finisher - 12-109(Interposer Feed Out Sensor OFF Jam) when paper is fed from interposer.
Chamonix/Pinot/teak/Mahogany field problem fixes.
IFM - None
HCS - None
PF3.2 HCF - Tray Shift mecha fail could be detected when tray is slowly pulled.
Return to
Setting
Subsystem Chain Link default value
Value
Note
after
5 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
initialization
Controller - - - - None
IOT None
IISS - - - - None
DADF - - - - None
C FIN - - - -
D4 Fin - - - -
IFM - - - -
HCS 991/992 205 40
991/992 206 34
991/992 207 29
991/992 208 24
991/992 209 40
991/992 210 34
991/992 211 29
991/992 212 24
991/992 213 20
991/992 214 15
991/992 215 14
991/992 216 20
991/992 217 15
991/992 218 14
991/992 230 0 50
991/992 231 0 47
991/992 322 0 40
991/992 323 0 34
991/992 324 0 29
991/992 235 0 24
991/992 236 0 20
991/992 237 0 15
991/992 238 0 14
991/992 239 0 1 1: Productivity improvement mode on MIX job
PF3.2 HCF - - - -
10/28/11 6
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
Subsystem # Corrections.
Controller - None
IOT - None
IISS - None
DADF - None
C Finisher - None
D4 Finisher - None
IFM - None
HCS - None
PF3.2 HCF - None
7 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Return to
default value Setting
Subsystem Chain Link
after Value
Note
initialization
Controller - - - - None
IOT See attached
IISS - - - - None
DADF - - - - None
C FIN - - - - None
D4 Fin - - - - None
IFM - - - - None
HCS - - - - None
PF3.2 HCF - - - - None
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
10/28/11 8
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller - At customer paper setting folding position can not be changed(ProWEB55219)
IOT - MSI on PF3.2HCF multi feed/jam misdetection countermeasure
Fail to DL IFM SW
Fuser Cold Not Ready cancel condition is not appropriate.
MSI Nudger Sol OFF timing is too early on 1st page auto size detection.
IISS - None
DADF - None
C Finisher - None
D4 Finisher - None
IFM - None
HCS - None
PF3.2 HCF - None
Return to
default value Setting
Subsystem Chain Link
after Value
Note
initialization
Controller - - - - None
IOT 741 351 0 Added
743 297 12 Default value change
IISS - - - - None
DADF - - - - None
C FIN - - - - None
D4 Fin - - - - None
IFM - - - - None
HCS - - - - None
PF3.2 HCF - - - - None
Restrictions
Detail of restrictions
9 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
Subsystem # Corrections.
Controller AR12136 Error45-310(ImageReadyNG)
AR12896 SPAR: Large impressions meter only counts once for duplex with non-standard size
sheets.
AR11922 When MSI is used and A3 or larger paper is selected folding and saddle stitch
position adjustment does not work.
IOT - There is possibility not to excute finisher collate job properly.
IISS - 3-318 occurs when scan job is canceled right after exiting from power pave mode.
DADF - Motor current limit change for 5-126 jam countermeasure
C Finisher - "Stacker Tray does not go down with the specific conditions.(Field problem:
Proweb-46478)"
NVM 763-038 cannot adjust a pitch between sets with “Set-to-set Pitch adj
additional value”
"Avoiding the Set Clamp Home SNR ON/OFF Fail detection error
"Stacker Upper Limit Fail cannot sometimes be detected in Stacker Tray Retry
operation.
D4 Finisher - Fix Gear mis-engagement in Booklet [Pinot QAT problem]
Add Transport system (012-003) related diagnostics.
10/28/11 10
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Return to
default value Setting
Subsystem Chain Link
after
Note
Value
initialization
Controller - - - - None
IOT - - - - When installing set version software & script files
with NVM Tool, all NVMs are automatically
changed.
IISS - - - - None
DADF - - - - None
C FIN - - - - None
D4 Fin - - - - None
IFM - - - - None
HCS - - - - None
PF3.2 HCF - - - - None
Restrictions
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
11 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
None
None
Restrictions
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
10/28/11 12
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller - None
IOT - Duplex job with Heavy SRA3 paper sometimes results in 045-314 Fail.
- Operator could not clear Fuser Jam (Message on IOT UI is not adequate)
IISS - None
DADF - None
C Finisher - None
D4 Finisher - None
IFM - None
HCS - None
PF3.2 HCF - Blower Heater control for Lower tray does not cover 200V –240V.
Return to
default value Setting
Subsystem Chain Link
after
Note
Value
initialization
Controller - - - - None
IOT - - - - See another sheet. When installing set version
software, all NVMs are automatically changed.
IISS - - - - None
DADF - - - - None
C FIN - - - - None
D4 Fin - - - - None
IFM - - - - None
HCS - - - - None
PF3.2 HCF - - - - None
Restrictions
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
13 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller AR116123 124-374 fail occurred when CE changed some NVM and exiting diagnostic mode
IOT - Fuser heater is on during paper jam. (Fuser heater should be off for safety reason)
IISS - None
DADF - None
C Finisher - None
D4 Finisher - Could not staple 25 sheets for 81-90 gsm by adjusting NVM.
Trimmer&SQF miscutting due to paper chip.
Bi-Fold job and Booklet SimplexMode sometimes result in 12-101Jam
IFM AR114764 047-310 fail occurred and IFM could not shut down.
TiMS106509 Pinot HCS Stacker Path sensor on Jam occured
IFM-TR-427 Illegal reset occured when ICP Component Control was executed.
IFM-TR-432 Decurler Motor Speed didn’t change
HCS - None
PF3.2 HCF - Shift Motor fuse blow by noise
10/28/11 14
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Return to
default value Setting
Subsystem Chain Link
after
Note
Value
initialization
Controller - - - None
IOT - - - None
IISS - - - None
DADF - - - None
C FIN - - - None
763 526 - 7 Booklet full set number setting for 91 - 176 gsm
paper. Decreasing from 20.
D4 Finisher 763 528 - 2 Booklet staple tamping action setting.
763 529 - 4 Booklet staple tamping counts setting.
763 548 - 1 Booklet additional tamping counts setting
763 549 - 2 Booklet staple hold additional tamping setting
763 550 - 1 Booklet tamping paper number setting
763 551 - 1 Interposer tamping paper number setting
763 543 - 1 Interposer UI binding adjustment setting
IFM - - - None
HCS - - - None
PF3.2 HCF - - - None
Restrictions
Detail of restrictions
Controller When installed this version to Ver1.x.x M/C, all NVM data should be automatically initialized.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None
HCS None.
PF3.2 HCF None.
15 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller AR113676 Alignment adjustment of custom paper does not reflect correctly when test print.
AR113855 DFE screen shows “Print is not available” after finishing DFE print job.
AR113950 Some AdVP paper jam zone should be added.
AR114071 Sometimes UI freeze happens when operator pushes job confirmation button on IOT
UI.
IOT AR114266 When paper jam occurred in D-Finisher, any jam screen does not appear on IOT UI.
IISS - None
DADF - None
C Finisher - Pre punch paper job is not executed correctly.
D4 Finisher - After staple dust full was detected, and operator popo the IOT, then somehow the
dust full fail was cleared.
- When AOS function was executed between HCS and D4 fin, 045-313(Logic Fail)
occurred.
IFM TR-420 When communication fail occurred between IOT and IFM, Advp MOT could not stop.
TR-417 IFM Decurler setting was automatically changed by paperweight, but LED indicator
position did not move on.
HCS - None
PF3.2 HCF - None
10/28/11 16
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Restrictions
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM Punch dust box near full is cleared by POPO. So if near full fail is once detected and POPO is done, dust
box full fail is suddenly detected. (No near full message displayed)
HCS None.
PF3.2 HCF None.
17 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Subsystem # Corrections.
Controller AR112463 Bi-fold Job can be started when Booklet Tray is broken.
AR112798 Saddle stitch Max (50mm) / Separate binding Max (50mm) Paper Size: 45-360 occurs
when 33rd postcard is fed.
AR112809 Trimming count does not exist in Job by Job summary report after executing bi-fold +
Trimming.
AR112823 Initial value of trimming cut amount in KO Tools differs from Spec.
(Described as [0.10~0.80])
AR112831 “No consumable needs to be replaced” is displayed on Consumable Information
Window when Cleaning cartridge is PreNear Empty.
AR113044 Correct finSupplyType,finSupplyMaxCapacity for Compile punch dust box.
AR113047 Entire diagram / detailed diagram is displayed incorrectly on Fault screen for D
Finisher- Staple NG.
AR113137 Punch by D-Fin is not executed when designating Box2Print while Coil Punch is
connected.
AR113139 Trimming is cancelled when designating 20mm for cut amount, and executing it.
AR113292 On Copy setting screen [Booklet Creation]: Its name is not displayed next to the two
buttons in 3rd column.
AR113293 Start conflict is triggered when trimming is set for minimum custom size 8.3x 11S.
AR113294 In K.O.Tools:[Image Quality Adjustment] is displayed instead of [Force Annotation]
AR113295 In K.O.Tools: [Current Settings] column in [Copy Control] is displayed blank.
AR113424 Coil Punch designation button shows up. But the graphics indicating the location of
CoilPunch is only displayed.
AR113540 Display related to Coil Puncher is not correct on Consumable Confirmation Screen.
AR113597 When 1 sheet x 1 set, No. of Job: 31 is started, machines stops after every 2 Jobs.
IOT AR 112596 When purposely misfeeding paper from the interposer on D4 Finisher, UI screen is
fixed to “Copying”.
FPAR21857 045-314 IOT SequenceTimeOver
FPAR22049
FPAR22106
AR 113671 HCS does not go down when pressing HCS removal button during PowerOn Sequence
in Pinot HCS.
- MOB Gain Tuning is not entered when replacing applicable HFSI.
- Sequence Time Over (045-314) occurs when paper type is being switched by ATS.
IISS AR112151 In rare cases, 003-341 occurs when recovering from IISS energy saving mode.
DADF - None.
C Finisher - None.
D4 Finisher 045-313(Logic Fail) occurs when output destination is switched from D4Fin to HCS,
and then to D4Fin.
IFM AR113439 127-311 occurs when paper is fed from Interposer.
HCS - None.
PF3.2 HCF No183 In rare cases, 45-313 (IOT Logic Fail) occurs due to PF 3.2 HCF when opening /
closing the interlock of Output device during Abuse Test.
10/28/11 18
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
19 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Restrictions
10/28/11 20
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
Detail of restrictions
Controller None.
IOT None.
IISS None.
DADF None.
C-Fin None.
D4 Fin None.
IFM None.
HCS None.
PF3.2 HCF None.
21 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
AR#
Controller 1 Mismatch between designated position and the icon at displaying Coil Punch list.
2 Start conflict problem on A4 paper being selected with Letter Coil punch.
3 Constrain problem on selecting Coil punch and Staple at teh same time.
4 Cannot select HCS when Coil Punch is selected.
5 Jam clear screen is not displayed when jam occurs at zone HCS 9 at HCS + D-Fin configuration
IOT Tray 3 bottom plate could not be lifted up.
Oscillation range of HCF PF 3.2 lower Tray is not correct.
C-Finisher None
D-Finisher AR112590 When the power is turned off/on after Staple Dust Full is detected, FULL
detection is canceled.
IFM 1.When system is running and operator open the AdvP interlock door, AdvP could not stop and feed the papers
remaining between IFM and AdvP.
2.User defined A4SEF job, 48-324(ICP Communication Fail) occured
3.State transition from Diagnostics mode to Normal mode, AdvP does not inform puncher status.
4.IFM device controller module sometimes informs puncher status many times.
5.When operator runs two sheets of coated paper, paper jam occurs at AdvP.
6.IFM could not stop when ICP Comm Fail occurred.
7.HCS could not stop when auto surface mode punched paper R/L=1 job.
8.Communication Fail occurred when A3S Coated paper dup job.
“ ”
9.When IFM receives Request Cancel command from IOT, IFM could not respond by Request Cancel“
” message.
10.NVM 769-245 is re-writable. (This NVM should not be re-writable)
HCS None
IISS None
IIT Ext None
DADF None
PF3.2HCF None
Restrictions
AdvP functionality :Normal Operation Only
Restrictions
Controller For AdvP Normal Operation Only
IOT Once IOT transit to cycle up state and down to standby state with no print cycle state, then IOT freeze. (Need
popo.)
Finisher None
IFM When GBC Advanced Punch is connected, change the following NVM settings.
1. 769-226 = 0: AdvP is not connected (Default)
= 1:AdvP is connected (type-A4)
= 2:AdvP is connected (type-Letter)
2. Jam Clear message does not appear when IFM Exit Sensor Static Jam is cleared.
3.“Paper Remain at I/F Transport SNR ON Jam” could not be detected.
4. In case that Jam is occurred and operator clear the caused paper but still remain other paper,
5.Pinot UI could not display correct static jam message.
HCS None
IISS None
IIT Ext None
DADF None
10/28/11 22
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
23 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
10/28/11 24
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
New
NVM NVM description Default Setting Note!
Setting
Controller - - - - -
IOT 746-071 Removed from Script
IOT 746-921 90 Transfer Bias
IOT 780-237 0 1 DRUM CRU Enable
IOT 751-505 2 0 DRUM Life based on print count
IOT 780-047 0 1 HCS Sample Print – Count mode
IOT 780-048 0 1 HCS Sample Print – DFE Control
AR#
Controller AR106721 AnalogWaterMark image paramater fix
IOT None
C-Finisher AR105740: When large-size paper set including small-size separator is output to Top tray, the 1st
sheet of a set is output/stacked skewed.
D-Finisher - Countermeasure against mis-registration on booklets
- Countermeasure against the jam due to the incorrect timing of I/P feeding that is caused when the
status is recovered after the occurrence of I/P Feed Out Snr On Jam
- [Pinot XC Test Trouble] Countermeasure against the tamper mis-position to 11x17 SEF,
Heavyweight paper 1. (A revision in Ver3.7.2)
IFM AR302 The reception timeout between bytes was detected.
AR307 Communication failure occurred while HFSI is being read.
AR308 Incorrect parameter was notified when the log was output.
HCS Improvement of detection Punch hole for Pinot.
Improvement of move timing of Roller-offset for Pinot.
Improvement of inappropriate control Mot-tamper-lead for Teak/Pinot.
IISS None
IIT Ext None
DADF None
PF3.2HCF 170 Feed Motor does not stop when feed stop command is sent between Feed
hotline and Feed start.
173 Himidily Fail detect range is wrong
171 AD value for Multi-feed detection is different from theoretical value.
172 Multi-feed detection sensor initial sampling problem fix
169 500ms delay for tray insetion
175 Shfit control bug at tray insertion with same paper size
176 Shtter fail at Tray insertion
177 Shift control bug at tray insertion with same but unfixed paper size.
Restrictions
Restrictions
Controller SW maturity for multi languages are about 90%.
IOT None
Finisher None
IFM None
HCS None
25 10/28/11
Xerox 700/700i DCP
700/700i DCP V3.7MN System Software Release Notes
IISS None
IIT Ext None
DADF None
1. When loading paper, ensure that all tray parameters are properly selected:
• Media weight
• Media weight/transparency
• Coated/Uncoated
• Standard/non-standard paper size
2. The Xerox 700DCP supports non-standard paper sizes. However, due to rounding
and unit-conversions that occur in the client applications, RIP, and printer, some
mismatch may occur between the paper size entered at the application, and the paper
size that must be entered at the printer. The operator may need to adjust the entered
paper dimensions by up to 0.1 inch (2.5mm) in order for the printer to detect that the
requested paper size has been loaded.
3. When the printer determines that a non-standard paper size is required for a job,
ensure that non-standard paper size is selected for the intended paper tray, and the
proper paper dimensions are entered in Customer tools mode.
10/28/11 26