Vessel ID mm

Design Case:
Operating Pressure

Operating temperature

Gas Flowrate kg/h


Gas MW
Gas Density kg/m3
Liquid Density kg/m3
Liquid Viscosity cP
Liquid Surface Tension mN/m

Drop let range considered ( min )


Drop let range considered ( max )

99.9% Droplet Capturer( Microns)


99.0% Droplet capturer ( Microns )
99% Removal of Droplets below (microns )

98.0% Droplet capturer(Microns)

Liquid Flowrate into Vanepack(I/Msm3)


Liquid Flowrate from Vanepack(I/Msm3)

Sizing Information:
Vane Type V-V Plain
Vane Pack Area m2
Vane Pack Shape
Diameter mm
Vane Pack(Demister )K Effective m/s
Vane Pack(Demister) Gas Velocity m/s
Vane Pack(Demister) Pressure Drop mbar ( Actual)
2700

1 bar

35 deg C

74700
29 ASSUMED
1.12
999.4
0.8
15 ASSUMED

5 ASSUMED
10 ASSUMED

10
8
6.5

<0.13 considered
<0.013

5.73
Circular
2700
0.108
3.24
1.17 11.938 mm H2O