method

the circuit in figure 2 is constructed and R4 as potentiometer.the voltage is


measured between point 'a' and 'b' using digitalmultimeter.The digitalmultimeter
has been set to measure voltage, positive probe at digitalmultimeter is connected
to point a and negative probe of digital multimeter is connected to point b.
the result is recorded in table 1.

the bridge is balanced using potentiometer. the volt is needed to set to 0 using
potentiometer and the volt value is referred at digitalmultimeter.Then,
the potentiometer is removed from the circuit and measured the resistance value.
the digitalmultimeter is set to resistance measured and put the probe of
digitalmultimeter at point 1 and 2 or 3 and 2 at potentiometer.
the result is recorded in table 2.

the circuit in figure 2 is constructed.


after that, the 10k potentiometer is replaced with 100k potentiometer.the resistor
of R3 also is replaced with unknown resistor no larger than 33k.
the bridge is balanced using potentiometer. the volt is needed to set to 0 using
potentiometer and the volt value is referred at digitalmultimeter.Then,
the potentiometer is removed from the circuit and measured the resistance value.
the digitalmultimeter is set to resistance measured and put the probe of
digitalmultimeter at point 1 and 2 or 3 and 2 at potentiometer.
the result is recorded in table 3.