Professional Documents
Culture Documents
Fugro Technical Services (Guangzhou) Limited: Registration No. HOKLAS 170 Page 1 of 11 28 March 2014 Ref: 170-24
Fugro Technical Services (Guangzhou) Limited: Registration No. HOKLAS 170 Page 1 of 11 28 March 2014 Ref: 170-24
Fugro Technical Services (Guangzhou) Limited: Registration No. HOKLAS 170 Page 1 of 11 28 March 2014 Ref: 170-24
HOKLAS 170
Page 1 of 11
28 March 2014
TEST
170 Ref: 170-24
CLIENTELE : Public
服務對象 公眾
* * * * * * * *
Registration No. HOKLAS 170
Page 2 of 11
28 March 2014
TEST
170 Ref: 170-24
Sound Power Level Measurement of sound power levels of noise ISO 3741: 1999
sources using sound pressure - precision BS EN ISO 3741: 2010
methods for reverberation rooms
Registration No. HOKLAS 170
Page 4 of 11
28 March 2014
TEST
170 Ref: 170-24
Clay, silt and dust content BS 812: Part 1: 1975 (Amd. 4875)
(Decantation method)
Particle densities and water absorption BS 812: Part 2: 1995 (Amd. 9195) (gas jar method)
Relative density and water absorption BS 812: Part 2: 1975 (Amd. 4615) (gas jar method)
Registration No. HOKLAS 170
Page 5 of 11
28 March 2014
TEST
170 Ref: 170-24
Concrete Air content of fresh concrete CS1: 1990 Section 6 (Amd. 1101 & 1102)
CS1: 2010 Section 6
BS EN 12350-7: 2000
Compressive strength of concrete cores CS1: 1990 Section 15 (Amd. 1201, 1203 & 1205)
in the force range 50 kN – 3000 kN CS1: 2010 Section 15
Compressive strength of concrete cubes CS1: 1990 Section 12 (Amd. 1201, 1202 & 1203)
in the force range 50 kN – 3000 kN CS1: 2010 Section 12
Density of hardened concrete CS1: 1990 Section 16 (Amd. 1201 & 1203)
CS1: 2010 Section 16
Making test cubes from fresh concrete CS1: 1990 Section 7 (Amd. 1101 & 1102)
CS1: 2010 Section 7
Mixing and sampling of fresh concrete CS1: 1990 Section 11 (Amd. 1201)
CS1: 2010 Section 11
Fire resistance tests for non-loadbearing BS EN 1364-1: 1999 (excl. Cl. 9.5)
elements – walls (excluding impact test)
Pre-test conditioning for doors, shutters and BS EN 14600: 2005, Cl. 5.1 (excl. Cl. 5.1.1.2)
openable windows and Cl. 5.3.2
Fire Smoke control test for smoke control doors BS EN 1634-3: 2004
(Smoke Control Tests) and shutters
Pre-test conditioning for doors, shutters and BS EN 14600: 2005, Cl.5.2 and 5.3.2
openable windows
Fire Non-combustibility test for building products BS 476: Part 4: 1970 (Amd. 2483 and 4390)
(Other) 建築材料不燃性試驗 EN ISO 1182: 2002
BS EN ISO 1182: 2010
GB/T 5464-1999
GB/T 5464-2010
Response to ignition by a small flame – Edge DIN 53438 Part 2: June 1984
ignition
Fire hazard testing – test flames – 50W IEC 60695-11-10: 1999+A1: 2003, Cl. 8
horizontal and vertical flame test methods – GB/T 2408-2008, Cl. 8
Horizontal burning test
塑膠 – 燃燒性能的測定-水平法
Fire hazard testing – test flames – 50W IEC 60695-11-10: 1999+A1: 2003, Cl. 9
horizontal and vertical flame test methods – GB/T 2408-2008, Cl. 9
Vertical burning test
塑膠 – 燃燒性能的測定-垂直法
Fire hazard testing – test flames – 500W flame IEC 60695-11-20: 1999+A1: 2003
test methods
Endurance test for flow controllers AS/NZS 3662: 2005 (Amd. 1) App. F
The Hong Kong Voluntary Water Efficiency Labelling
Scheme on Showers for Bathing (Jun 2009) Annex 1
Section II D