Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

M4Y/M4W/M5W/M4M Series

▣ Panel meter selection Ⅱ


※This panel meter selection is except MT4N / MT4Y / MT4W Series.

Digital panel meter

Display digit
41/2 Digit 31/2 Digit

72

96 96
72 Size

72
48

48
36

Output
Indicator Single output setting Dual output setting

M5W Series
M4Y Series M4W1P Series M4W2P Series Series
M4W Series M4M1P Series M4M2P Series
M4M Series

DC Voltage DC Current rpm Power factor Measurement


Power Scaling
AC Current AC Current speed (M4W-P)

Page
L-52 L-54 L-56 L-57 L-58 L-59

L-48
Digital Panel Meter

Specifications (A)
Photo
electric
sensor
Classification Indicator Single preset output type Dual preset output type
(B)
Fiber
M4Y-DV- M4W-DV- M4W1P-DV- M4W2P-DV- optic
DC, AC M4Y-AV - M4W-AV - M4W1P-AV - M4W2P-AV - sensor

voltage M5W-DV- M4M-DV- M4M1P-DV- M4M2P-DV-


(C)
M5W-AV- M4M-AV - M4M1P AV - M4M2P-AV - Door/Area
sensor
M4Y-DA- M4W-DA- M4W1P-DA- M4W2P-DA-
DC, AC M4Y-AA - M4W-AA - M4W1P-AA - M4W2P-AA - (D)
ampere M5W-DA- M4M-DA- M4M1P-DA- M4M2P-DA- Proximity
Measurement

sensor
M5W-AA - M4M-AA - M4M1P-AA - M4M2P-AA -
AC power M4Y-W- ☐ M4W-W- ☐ M4W1P-W- M4W2P-W (E)
Pressure
(0-10VDC) M5W-W- ☐ M4M-W- ☐ M4M1P-W- M4M2P-W sensor

M4Y-T ☐- ☐ M4W-T ☐- ☐ M4W1P-T - M4W2P-T -


rpm, speed (F)
M4Y-S ☐- ☐ M4W-S ☐- ☐ M4W1P-S - M4W2P-S - Rotary
(0-10VDC) encoder
M5W-T- ☐ M4M-T- ☐ M4M1P-T- M4M2P-T-
(0-10VAC)
M5W-S- ☐ M4M-S- ☐ M4M1P-S- M4M2P-S-
(G)
Connector/
Power factor M4W-P Socket
- - -
(DC4-20mA) (Refer to L-57)
(H)
Temp.
Max. allowable input 150% for each input specification(At 400VAC:120%) controller

100-240VAC 50/60Hz
110/220VAC 50/60Hz (I)
★ 5VDC SSR/
Power supply ★ 24-70VDC Power
(Except for M5W)
★ 100-240VAC 50/60Hz controller
★ 24-70VDC
(J)
Allowable voltage range 90 to 110% of rated voltage Counter

Power consumption DC: 2W, AC: 4VA DC: 3W, AC: 5VA
(K)
Display method 7 Segment LED display Timer

Character height M4Y, M4W, M5W : 14mm / M4W1P, M4W2P, M4M1P, M4M2P : 10mm
(L)
DC : F.S. ±0.2% rdg ±1digit Panel
Display accuracy
AC : F.S. ±0.5% rdg ±1digit meter

Sampling period 300ms (M)


Tacho/
Speed/ Pulse
A/D conversion method Dual slope integral method meter

Response time 2sec.(0 to Max.) (N)


Display
Display frequency 2.5 times/sec. unit

Relay contact output : Relay contact output :


Contact capacity - (O)
250VAC 3A 1c 250VAC 3A 1c×2 Sensor
controller
Insulation resistance 100MΩ(at 500VDC megger)
(P)
Dielectric strength 2000VAC 50/60Hz for 1 minute Switching
mode power
supply
Noise strength ±1kV the square wave noise (pulse width: 1us) by the noise simulator
(Q)
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour Stepper
Vibration motor&
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes Driver&Controller

(R)
Mechanical 300m/s²(approx. 30G) in X, Y, Z directions for 3 times Graphic/
Shock Logic
Malfunction 100m/s²(approx. 10G) in X, Y, Z directions for 3 times panel

(S)
Relay Mechanical - Min. 10,000,000 operations Field
network
life cycle Malfunction - Min. 100,000 operations (250VAC 3A resistive load) device

Environ- Ambient temperature -10 to 50℃, storage: -20 to 60℃ (T)


Software
ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
M4W: Approx. 168g
M4Y: Approx. 144g M4W1P: Approx. 253g M4W2P: Approx. 278g (U)
Unit weight M4M: Approx. 262g Other
M5W: Approx. 172g M4M1P: Approx. 290g M4M2P: Approx. 316g
(M4M-P: Approx. 268g)
※"★" symbol in power supply is optional. (customizable)
※Environment resistance is rated at no freezing or condensation.

L-49
M4Y/M4W/M5W/M4M Series

Dimensions (unit: mm)


● M4Y ● Panel cut-out

Min. 91
85
72 7 93

31+ 00.5
Min. 40
67 + 00.7
36

30
※Unit will be displayed in of front panel.

(unit: mm)
● M4W ● M4W1P ● M4W2P ● M5W

● Panel cut-out
Min. 116
98
96 12 104

45 + 00.6
Min. 52

+ 0.8
92
48

45

※Unit will be displayed in of front panel.

(unit: mm)
● M4M ● M4M1P ● M4M2P

● Panel cut-out
Min. 91
86
72 13 113
68+ 00.7
Min. 91

68+ 00.7
67

※Unit will be displayed in of front panel.

L-50
Digital Panel Meter

Connections (A)
Photo
electric
sensor

● M4Y ● M4M (B)


INPUT HOLD Fiber
optic
HI LOW sensor
1 2 3 4 5 6
+ -
(C)
+ - 8 9 10 11 12 13 14 Door/Area
sensor
HIGH LOW - +
15 INPUT HOLD 17
SOURCE (D)
100-240VAC 50/60Hz 110VAC 220VAC
Proximity
16 18 sensor
5VDC(Option) 50/60Hz 50/60Hz
0V
24-70VDC(Option)
1 2 3 4 5 6 7 (E)
Pressure
● M4W sensor
220VAC 110VAC
INPUT HOLD 50/60Hz 50/60Hz 0V
SOURCE Power option (F)
Rotary
1 2 3 4 5 6 7 8 DC SMPS AC SMPS encoder
Power Power
+ - (G)
1 2 3 1 2 3
HI LOW Power option
Connector/
Socket
SOURCE DC SMPS AC SMPS + -
Power Power 100-240VAC
24-70VDC 2W 50/60Hz 4VA (H)
6 7 8 6 7 8 Temp.
controller

- +
100-240VAC (I)
24-70VDC 50/60Hz 4VA ● M4M1P SSR/
Power
controller

● M5W HI LOW
+ - (J)
INPUT Counter
8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 INPUT HOLD
15 17
(K)
Timer
+ - 110VAC 220VAC NO NC
HI LOW 16 18
- + 0V 50/60Hz 50/60Hz COM
1 2 3 4 5 6 7 (L)
SOURCE Panel
HI SET OUT meter
100-240VAC 50/60Hz
24-70VDC(Option) : 250VAC 3A 1c
RESISTIVE LOAD (M)
Tacho/
SOURCE
● M4W1P N.C. N.O. Power option
Speed/ Pulse
meter
RELAY CONTACT OUT
COM DC SMPS AC SMPS
: 250VAC 3A 1c Power Power (N)
RESISTIVE LOAD Display
9 10 11 12 13 14 15 16 unit
1 2 3 1 2 3
HI OUT
(O)
220VAC 110VAC + - Sensor
INPUT HOLD 50/60Hz 50/60Hz 0V 100-240VAC
controller
24-70VDC 2W 50/60Hz 5VA

1 2 3 4 5 6 7 8 (P)
Switching
+ - Power option mode power
HI LOW DC SMPS AC SMPS ● M4M2P supply

Power Power
(Q)
SOURCE 6 7 8 6 7 8 HI LOW Stepper
motor&
+ - Driver&Controller
- +
100-240VAC 8 9 10 11 12 13 14 (R)
24-70VDC 50/60Hz 4VA Graphic/
INPUT HOLD Logic
15 17 panel
● M4W2P COM
(S)
16 110VAC 220VAC NO NC 18 Field
RELAY CONTACT 0V 50/60Hz 50/60Hz COM NO NC network
device
NC NO OUT :250VAC 3A 1c NC NO 1 2 3 4 5 7
COM RESISTIVE LOAD COM HI SET OUT LOW SET OUT (T)
9 10 11 12 13 14 15 16 : 250VAC 3A 1c : 250VAC 3A 1c Software
RESISTIVE LOAD RESISTIVE LOAD
LOW OUT HI OUT SOURCE Power option (U)
Power option
220VAC 110VAC DC SMPS AC SMPS
Other
INPUT HOLD 50/60Hz 50/60Hz 0V DC SMPS AC SMPS Power Power
Power Power
1 2 3 4 5 6 7 8 6 7 8 6 7 8 1 2 3 1 2 3

+ - + -
- +
HI LOW 100-240VAC 100-240VAC
24-70VDC 50/60Hz 5VA 24-70VDC 3W 50/60Hz 5VA
SOURCE

L-51
M4Y/M4W/M5W/M4M Series

DIN W72×H36mm, W96×H48mm, W72×H72mm


Digital panel meter for measuring voltage
Features
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or Hold function(Except for M5W)
● RMS/AVG value selection function(AC Voltage)
● 7 Segment LED Display
● Case size by DIN specification
● Indicator, Single preset output type,
Dual preset output type
Please read “Caution for your safety” in operation
manual before using.

Ordering information
M 4 W AV 1

M4Y / M4W / M4M M5W


NO DC INPUT AC INPUT DC INPUT AC INPUT
(F.S.) (F.S.) (F.S.) (F.S.)
1 199.9mV 199.9mV 199.99mV 199.99mV
Measuring 2 1.999V 1.999V 1.9999V 1.9999V
※1
input 3 19.99V 19.99V 19.999V 19.999V
4 199.9V 199.9V 199.99V 199.99V
※2
5 300V - 300.0V 400.0V
※2
6 - 400V - -
XX Option Option
AC measuring
method No mark AVG value
※3
R RMS value
DV DC Volt
Input DA DC Ampere
AV AC Volt
AA AC Ampere

No mark Indicator
Output
1P Single setting
2P Dual setting
※4
Size Y DIN W72×H36mm
※4
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter

※1: Measuring input and display are 1:1.


※2: Available input can be direct connection if under 300VDC, 400VAC.
※3: M5W AC measurement type has RMS only. It does not have "R" in model name.
※4: M4Y, M5W are indicator.

L-52
Digital Panel Meter

The application of connections Proper usage (A)


Photo

Measuring DC voltage
electric
● Please notice the product customized by requirement sensor

cannot be replaced. (B)


Hi Fiber
● If it displays arbitrary number even though the power is optic
sensor
ON, please remove the input signal and check whether
V1 Load D.P.M Power supply
it displays "000" after short the measurement terminal. (C)
Door/Area
(Checking auto zero function) sensor
Low
If it does not display "000", please connect to our A/S
(Fig. 1) Measuring lower than 300VDC of measurement center.
(D)
Proximity
voltage (V1) sensor
Note)M5W Series does not have auto zero function.
Multiplier ● If it indicates "1999" or "`999" during input signal is ON, (E)
Pressure
please turn OFF the power and check the connection sensor
R1
condition.
Hi (F)
It is because the input signal is too low or high. Note) Rotary
encoder

Load D.P.M Power supply M5W Series indicates "19999" or "`9999".


V1 V2 R2
● The specification of measurement input, which (G)
Connector/

Low is indicated in ordering information, is a standard Socket

specification, 1:1 of measurement input and process


(Fig. 2) Measuring higher than 300VDC of measurement value. When it is an optional specification of AC voltmeter,
(H)
Temp.
voltage controller
please mark the specification of P.T after select a model.
※When measuring voltage is higher than 300VDC, please ※Please notice P.T is not included. (I)
SSR/
select R1 and R2 with multiplying resistance on the ex- Power
● The D.P.M for measuring AC voltage has both AVG type controller
ternal to make V2 less than max. measurement voltage.
and RMS type separately. Because it is produced with
AVG type, please mark the model name accurately. (J)
R2 Counter
V3 = × V1 R1 > R2 Ex)In case of M4Y, M4W, M4M Series (Include setting
R1 + R2
type) (K)
Ex)Ordering D.P.M for measuring 1000VDC The model of RMS type: M4W-AVR-6
Timer

As above Fig. 2, select the R1 value to make 300VDC


on R2. The model of AVG type: M4W-AV-6 (L)

(Generally R1 value will be higher than R2 value.) ※The specification will be set by sign "R". Panel
meter

Order the D.P.M indicating 1000V for 300VDC. ※M5W Series has RMS type only, and it is not (M)
indicated "R" on the model name. Tacho/
Speed/ Pulse
Measuring AC voltage ● In case of D.P.M for measuring AC voltage, please check
meter

Hi if it is AVG type or RMS type when comparison measuring (N)


Display
with other company's products. unit

V1 Load D.P.M Power supply


(O)
Sensor
controller
Low
(Fig. 3) Measuring lower than 400VAC of measurement (P)
Switching
voltage (V1) mode power
supply
P.T
(Q)
Stepper
Hi
N1 N2 motor&
Driver&Controller

V1 Load V2 D.P.M Power supply (R)


Graphic/
Logic
panel
Low
(S)
Field
(Fig. 4) Measuring higher than 400VAC of measurement network
device
voltage (V1)
※When measuring voltage is higher than 400VAC, please (T)
Software
use the P.T on the external. (V2 voltage must be lower
than max. measurement voltage)
(U)
Other
N2
V2 = × V1
N1
Ex)Ordering D.P.M for measuring 1000VAC
Select the P.T having 1000VAC of 1st part voltage and
220VAC of 2nd part voltage and order the D.P.M indi-
cating 1000V for 220VAC.

L-53
M4Y/M4W/M5W/M4M Series

DIN W72×H36mm, W96×H48mm, W72×H72mm


Digital panel meter for measuring ampere
Features
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or hold function(Except for M5W)
● RMS/AVG value selection function(AC Voltage)
● 7 Segment LED display
● Case size by DIN specification
● Indicator, single preset output type,
Dual preset output type
Please read “Caution for your safety” in operation
manual before using.

Ordering information
M 4 W AA 1
M4Y / M4W / M4M M5W
NO DC INPUT AC INPUT DC INPUT AC INPUT
(F.S.) (F.S.) (F.S.) (F.S.)
1 199.9μA 19.99mA 199.99μA 19.999mA
2 1.999mA 199.9mA 1.9999mA 199.99mA
Measuring 3 19.99mA 1.999A 19.999mA 1.9999A
※1
input 4 199.9mA 19.99A 199.99mA 19.999A
5 1.999A 199.9A 1.9999A 199.99A
6 19.99A 1999A 19.999A 1999.9A
7 199.9A - 199.99A -
8 1999A - 1999.9A -
XX Option Option
AC measuring
method No mark AVG value
※2
R RMS value

DV DC Volt
Input DA DC Ampere
AV AC Volt
AA AC Ampere

Output No mark Indicator


1P Single setting
2P Dual setting
※3
Size Y DIN W72×H36mm
※3
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter

※1: Measuring input and display is 1:1 for DC INPUT No.1to 5 and AC INPUT No.1 to 3, DC INPUT No.6 to 8 is
used with DC50mV Shunt, AC INPUT No.4 to 6 are used with C.T(Current transformer)
※2: M5W AC measurement type has RMS only. It does not have "R" in model name.
※3: M4Y, M5W are indicator.

L-54
Digital Panel Meter

Connections Proper usage (A)


Photo

Measuring DC ampere
electric
● Please notice the product customized by requirement sensor

cannot be replaced. (B)


I Fiber
Hi ● If it displays arbitrary number even though the power is optic
sensor
ON, please remove the input signal and check whether
+
V D.P.M Power supply it displays "000"after short the measurement terminal. (C)
Door/Area
- (Checking auto Zero function) sensor

Low If it does not display "000", please connect to our A/S


Load (D)
center. Proximity
sensor
Note) M5W Series does not have auto zero function.
(Fig. 1) Measuring lower than DC2A of current
● If it indicates "1999" or "`999"during input signal is ON, (E)
Pressure
I please turn OFF the power and check the connection sensor

Hi
Shunt condition.
(F)
+ It is because the input signal is too low or high. Rotary
encoder
V DC50mV D.P.M Power supply
- Note) M5W Series indicates "19999" or "`9999".
(G)

Low ● The specification of measurement input, which Connector/


Load Socket
is indicated in ordering information, is a standard
specification, 1:1 of measurement input and process (H)
(Fig. 2) Measuring higher than DC2A of current value. Temp.
controller

※Higher than DC2A is using shunt for measuring current. ※Please notice a shunt and C.T are not included.
(I)
※Basically the 2nd part of shunt value is DC50mV. ● The D.P.M for measuring AC ampere has both AVG type SSR/
Power

Ex) Ordering D.P.M in case of DC10A of measuring ampere: and RMS type separately. controller

Select DC10A/50mVDC of shunt and 50mVDC/DC10.00A Because it is produced with AVG type, please mark the (J)
of D.P.M. model name accurately. Counter

Ex) In case of M4Y, M4W, M4M Series(Include setting


Measuring AC ampere type) (K)
Timer

I The model of RMS type: M4W-AAR-5


Hi The model of AVG type: M4W-AA-5 (L)
Panel
meter
※The specification will be set by sign "R".
D.P.M Power supply ※M5W Series has RMS type only, and it is not (M)
Tacho/
indicated "R" on the model name. Speed/ Pulse
meter
Load Low
● In case of D.P.M for measuring AC ampere, please
(N)
check if it is AVG type or RMS type when comparison Display
unit
(Fig. 3) Measuring lower than AC5A of current measuring with other company's products.
Ex) Ordering D.P.M in case of lower than AC5A of (O)
Sensor
measuring ampere : Select M4W-AA-XX AC5A/5.00A controller

(P)
I Switching
mode power
Hi supply

(Q)
C.T D.P.M Power supply Stepper
motor&
Driver&Controller

(R)
Load Low Graphic/
Logic
panel

(Fig. 4) Measuring higher than AC5A of current (S)


Field
※If the current is higher than AC5A, please use C.T. network
device

Ex) How to order D.P.M in case of AC300A of measuring (T)


Software
ampere : Select AC300A/5A of C.T and AC5A/300A of
D.P.M.
(U)
Other

L-55
M4Y/M4W/M5W/M4M Series

DIN W72×H36mm, W96×H48mm, W72×H72mm


Digital panel meter for measuring power
Features
● Max. display : 19999(M5W), 1999(Others)
● Auto zero function and hold function(Except for M5W)
● Display the output(0-10VDC) from power converter.
(It is available to correspond when output is DC4-
20mA, 1-5VDC.)
● 7 Segment LED display
● Case size by DIN specification.
● Indicator, single preset output type, Dual preset out-
put type
Please read “Caution for your safety” in operation
manual before using.

Ordering information
M 4 W W 1

M4Y / M4W / M4M M5W


NO
DISPLAY(F.S.) DISPLAY(F.S.)
1 199.9W 199.99W
2 1.999kW 1.9999kW
※1
Display scale 3 19.99kW 19.999kW
4 199.9kW 199.99kW
5 1999kW 1999.9kW
XX Option Option
Measurement function
W Watt Meter

No mark Indicator
Output
1P Single setting
2P Dual setting
※2
Y DIN W72×H36mm
Size ※2
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter

※1: When output specification of power converter is 0-10VDC, display value is maximum.
※2: M4Y, M5W are indicator.
※If output specification of Converter or power converter is DC4-20mA or 1-5VDC, please use scaling meter.

Application of connection
L1 L2 L3
P.T + ● The specification of measuring input indicated
in ordering information, is display value output
specification is 0-10VDC.
P.T ● When the output of transducer or converter is
Hi DC4-20mA or 1-5VDC, please use scaling meter.
Output : D.P.M Power supply
DC0-10V
C.T Low

C.T

Load (Transducer)

L-56
Digital Panel Meter

DIN W72×H36mm, W96×H48mm, W72×H72mm (A)


Photo
electric

Digital panel meter for measuring Revolution/Speed sensor

(B)
Features Fiber
optic
sensor
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or hold function(Except for M5W) (C)
Door/Area
● RMS/AVG value selection function(AC voltage) sensor

● 7 Segment LED display (D)


● Case size by DIN specification Proximity
sensor
● Indicator, single preset output type, Dual preset
output type (E)
Pressure
sensor
Please read “Caution for your safety” in operation
manual before using.
(F)
Rotary
encoder

Ordering information (G)


Connector/
M 4 W T 1 Socket

(H)
Temp.
controller

(I)
SSR/
M4Y / M4W / M4M M5W Power
NO controller
INPUT (F.S.) INPUT (F.S.)
1 0-10VDC / 1999 0-10VDC / 1999.9 (J)
Counter
Measuring input 2 0-10VAC / 1999 0-10VAC / 1999.9
DX DC Input option DC Input option
(K)
XX AC Input option AC Input option Timer

AC measuring
method No mark AVG value (L)
※1 Panel
R RMS value meter

Measurement function T Tachometer(rpm) (M)


Tacho/
S Line Speed Meter(m/min) Speed/ Pulse
meter

No mark Indicator
Output (N)
1P Single setting output Display
unit
2P Dual setting output
※2
(O)
Y DIN W72×H36mm Sensor
Size ※2
controller
W DIN W96×H48mm
(P)
M DIN W72×H72mm Switching
mode power
Digit 4 1999(3½digit)
supply

(Q)
5 19999(4½digit) Stepper
Item motor&
Driver&Controller
M Meter
(R)
※1: AC measuring type of M5W only applies to RMS and it is not marked with "R" in the model name. Graphic/
Logic
※2: M4Y, M5W are indicator. panel

(S)
Field
network
device
Application of connection
(T)
Software
● Tacho Generator(T.G)
This generator makes a voltage in proportion to revolu-
M HI tion speed of motor. The D.P.M receives the voltage (U)
Other
T.G and displays the number of revolution and please check
D.P.M POWER
the specification of T.G.
LOW
● The specification of measuring input indicated in order-
Motor Tacho Generator Tacho/Speed meter ing information, is display value when output specifica-
tion is 0-10VDC and 0-10VAC. Different output specifi-
cation of tacho generator is optional.

L-57
M4Y/M4W/M5W/M4M Series

DIN W72×H36mm, W96×H48mm, W72×H72mm


Digital scaling meter
Features
● Max. display : 19999(M5W), 1999(Others)
● 7 Segment LED display
● Case size by DIN specification
● Linear display function by INPUT specification
● Indicator, single preset output type, dual preset output
type
Please read “Caution for your safety” in operation
manual before using.

Ordering information
M 4 W DI X

Display scale
X Display range(Option)
Input
DI DC4-20mA(1-5VDC : Option※1)
No mark Indicator
Output
1P Single setting
2P Dual setting
※2
Y DIN W72×H36mm
Size ※2
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter
※1: 1-5VDC of measuring input specification is available by option.
It will be a default value if there is no request for order.
※2: M4Y, M5W are indicator.

Application of connection
(+)
CONVERTER

HI
Temperature Sensor
Output:DC4-20mA Power supply
Pressure Sensor (1-5VDC: Option) D.P.M
LOW
(-)
(Transducer)

● The measurement input specification of ordering information, is an output specification of converter and DC4-20mA is the
standard specification. In case, the output of converter is 1-5VDC, it is customizable.
● DC voltmeter can be produced by requirement, in case, it is out of the 1-5VDC output specification.

L-58
Digital Panel Meter

DIN W96×H48mm, Digital panel meter for displaying power factor (A)
Photo
electric
sensor

Features (B)
Fiber
● Display indicator of power factor optic
sensor

● Input : DC4-20mA(Output specification of


(C)
power factor transducer) Door/Area
sensor
● Display : -0.50 to 1.00 to +0.50
(D)
Please read “Caution for your safety” in operation Proximity
manual before using. sensor

(E)
Ordering information Pressure
sensor

M 4 W P (F)
Rotary
encoder
Measurement function
P Power Factor (G)
Connector/
Size Socket
W DIN W96×H48mm
Digit
4 9999(4digit) (H)
Temp.
Item controller
M Meter
(I)
Specifications SSR/

Connections
Power
controller
Model M4W-P
Measurement function Power factor INPUT 220VAC 110VAC (J)
50/60Hz 50/60Hz 0V Counter
Input DC4-20mA
Display -0.50 to 1.00 to +0.50 cosø 1 2 3 4 5 6 7 8
(K)
Power supply 110/220VAC 50/60Hz + - Timer

Allowable voltage range 90 to 110% of rated voltage HI LOW


(L)
Power consumption 4VA Panel
SOURCE meter
Display method 7 Segment LED display
Character height 14mm (M)
Tacho/
Speed/ Pulse
Display accuracy F.S: ±3% rdg ±1digit meter
Sampling period 300ms Application of connection (N)
Response speed 2sec.(0 to Max.) Display
unit
Point display Fixed point L1 L2 L3
P.T +
Insulation resistance Min. 100MΩ(at 500VDC megger) (O)
Sensor
Dielectric strength 2000VAC 50/60Hz for 1 minute controller

±1kV the square wave noise(pulse width : 1㎲) P.T


Noise strength (P)
by the noise simulator Hi Switching
0.75mm amplitude at frequency of 10 to 55Hz Output : Power mode power
Mechanical DPM supply supply
(for 1 min.) in each of X, Y, Z directions for 1 hour C.T
DC4-20mA
Vibration Low
0.5mm amplitude at frequency of 10 to 55Hz (Q)
Malfunction Stepper
(for 1 min.) in each of X, Y, Z directions for 10 minutes C.T motor&
Driver&Controller
Mechanical 300m/s²(approx. 30G) in each of X, Y, Z directions for 3 times
Shock (R)
Malfunction 100m/s²(approx. 10G) in each of X, Y, Z directions for 3 times - Graphic/
Ambient LOAD (Power factor Logic
panel
Environ -10 to 50℃, storage : -25 to 60℃ transducer)
temperature
-ment (S)
Ambient humidity 35 to 85%RH, storage : 35 to 85%RH Field
network
Unit weight Approx. 317g device

※Environment resistance is rated at no freezing or condensation.


(T)
(unit: mm)
Dimension ● Panel cut-out
Software

98
Min. 116 (U)
96 12 104 Other
45 + 00.6
Min. 52

92 +0.8
48

45

L-59