Professional Documents
Culture Documents
Dong Ho Do Dien AP Autonics M4M Series Catalogue 30092017032134
Dong Ho Do Dien AP Autonics M4M Series Catalogue 30092017032134
Display digit
41/2 Digit 31/2 Digit
72
96 96
72 Size
72
48
48
36
Output
Indicator Single output setting Dual output setting
M5W Series
M4Y Series M4W1P Series M4W2P Series Series
M4W Series M4M1P Series M4M2P Series
M4M Series
Page
L-52 L-54 L-56 L-57 L-58 L-59
L-48
Digital Panel Meter
Specifications (A)
Photo
electric
sensor
Classification Indicator Single preset output type Dual preset output type
(B)
Fiber
M4Y-DV- M4W-DV- M4W1P-DV- M4W2P-DV- optic
DC, AC M4Y-AV - M4W-AV - M4W1P-AV - M4W2P-AV - sensor
sensor
M5W-AA - M4M-AA - M4M1P-AA - M4M2P-AA -
AC power M4Y-W- ☐ M4W-W- ☐ M4W1P-W- M4W2P-W (E)
Pressure
(0-10VDC) M5W-W- ☐ M4M-W- ☐ M4M1P-W- M4M2P-W sensor
100-240VAC 50/60Hz
110/220VAC 50/60Hz (I)
★ 5VDC SSR/
Power supply ★ 24-70VDC Power
(Except for M5W)
★ 100-240VAC 50/60Hz controller
★ 24-70VDC
(J)
Allowable voltage range 90 to 110% of rated voltage Counter
Power consumption DC: 2W, AC: 4VA DC: 3W, AC: 5VA
(K)
Display method 7 Segment LED display Timer
Character height M4Y, M4W, M5W : 14mm / M4W1P, M4W2P, M4M1P, M4M2P : 10mm
(L)
DC : F.S. ±0.2% rdg ±1digit Panel
Display accuracy
AC : F.S. ±0.5% rdg ±1digit meter
(R)
Mechanical 300m/s²(approx. 30G) in X, Y, Z directions for 3 times Graphic/
Shock Logic
Malfunction 100m/s²(approx. 10G) in X, Y, Z directions for 3 times panel
(S)
Relay Mechanical - Min. 10,000,000 operations Field
network
life cycle Malfunction - Min. 100,000 operations (250VAC 3A resistive load) device
L-49
M4Y/M4W/M5W/M4M Series
Min. 91
85
72 7 93
31+ 00.5
Min. 40
67 + 00.7
36
30
※Unit will be displayed in of front panel.
(unit: mm)
● M4W ● M4W1P ● M4W2P ● M5W
● Panel cut-out
Min. 116
98
96 12 104
45 + 00.6
Min. 52
+ 0.8
92
48
45
(unit: mm)
● M4M ● M4M1P ● M4M2P
● Panel cut-out
Min. 91
86
72 13 113
68+ 00.7
Min. 91
68+ 00.7
67
L-50
Digital Panel Meter
Connections (A)
Photo
electric
sensor
- +
100-240VAC (I)
24-70VDC 50/60Hz 4VA ● M4M1P SSR/
Power
controller
● M5W HI LOW
+ - (J)
INPUT Counter
8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 INPUT HOLD
15 17
(K)
Timer
+ - 110VAC 220VAC NO NC
HI LOW 16 18
- + 0V 50/60Hz 50/60Hz COM
1 2 3 4 5 6 7 (L)
SOURCE Panel
HI SET OUT meter
100-240VAC 50/60Hz
24-70VDC(Option) : 250VAC 3A 1c
RESISTIVE LOAD (M)
Tacho/
SOURCE
● M4W1P N.C. N.O. Power option
Speed/ Pulse
meter
RELAY CONTACT OUT
COM DC SMPS AC SMPS
: 250VAC 3A 1c Power Power (N)
RESISTIVE LOAD Display
9 10 11 12 13 14 15 16 unit
1 2 3 1 2 3
HI OUT
(O)
220VAC 110VAC + - Sensor
INPUT HOLD 50/60Hz 50/60Hz 0V 100-240VAC
controller
24-70VDC 2W 50/60Hz 5VA
1 2 3 4 5 6 7 8 (P)
Switching
+ - Power option mode power
HI LOW DC SMPS AC SMPS ● M4M2P supply
Power Power
(Q)
SOURCE 6 7 8 6 7 8 HI LOW Stepper
motor&
+ - Driver&Controller
- +
100-240VAC 8 9 10 11 12 13 14 (R)
24-70VDC 50/60Hz 4VA Graphic/
INPUT HOLD Logic
15 17 panel
● M4W2P COM
(S)
16 110VAC 220VAC NO NC 18 Field
RELAY CONTACT 0V 50/60Hz 50/60Hz COM NO NC network
device
NC NO OUT :250VAC 3A 1c NC NO 1 2 3 4 5 7
COM RESISTIVE LOAD COM HI SET OUT LOW SET OUT (T)
9 10 11 12 13 14 15 16 : 250VAC 3A 1c : 250VAC 3A 1c Software
RESISTIVE LOAD RESISTIVE LOAD
LOW OUT HI OUT SOURCE Power option (U)
Power option
220VAC 110VAC DC SMPS AC SMPS
Other
INPUT HOLD 50/60Hz 50/60Hz 0V DC SMPS AC SMPS Power Power
Power Power
1 2 3 4 5 6 7 8 6 7 8 6 7 8 1 2 3 1 2 3
+ - + -
- +
HI LOW 100-240VAC 100-240VAC
24-70VDC 50/60Hz 5VA 24-70VDC 3W 50/60Hz 5VA
SOURCE
L-51
M4Y/M4W/M5W/M4M Series
Ordering information
M 4 W AV 1
No mark Indicator
Output
1P Single setting
2P Dual setting
※4
Size Y DIN W72×H36mm
※4
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter
L-52
Digital Panel Meter
Measuring DC voltage
electric
● Please notice the product customized by requirement sensor
(Generally R1 value will be higher than R2 value.) ※The specification will be set by sign "R". Panel
meter
Order the D.P.M indicating 1000V for 300VDC. ※M5W Series has RMS type only, and it is not (M)
indicated "R" on the model name. Tacho/
Speed/ Pulse
Measuring AC voltage ● In case of D.P.M for measuring AC voltage, please check
meter
L-53
M4Y/M4W/M5W/M4M Series
Ordering information
M 4 W AA 1
M4Y / M4W / M4M M5W
NO DC INPUT AC INPUT DC INPUT AC INPUT
(F.S.) (F.S.) (F.S.) (F.S.)
1 199.9μA 19.99mA 199.99μA 19.999mA
2 1.999mA 199.9mA 1.9999mA 199.99mA
Measuring 3 19.99mA 1.999A 19.999mA 1.9999A
※1
input 4 199.9mA 19.99A 199.99mA 19.999A
5 1.999A 199.9A 1.9999A 199.99A
6 19.99A 1999A 19.999A 1999.9A
7 199.9A - 199.99A -
8 1999A - 1999.9A -
XX Option Option
AC measuring
method No mark AVG value
※2
R RMS value
DV DC Volt
Input DA DC Ampere
AV AC Volt
AA AC Ampere
※1: Measuring input and display is 1:1 for DC INPUT No.1to 5 and AC INPUT No.1 to 3, DC INPUT No.6 to 8 is
used with DC50mV Shunt, AC INPUT No.4 to 6 are used with C.T(Current transformer)
※2: M5W AC measurement type has RMS only. It does not have "R" in model name.
※3: M4Y, M5W are indicator.
L-54
Digital Panel Meter
Measuring DC ampere
electric
● Please notice the product customized by requirement sensor
Hi
Shunt condition.
(F)
+ It is because the input signal is too low or high. Rotary
encoder
V DC50mV D.P.M Power supply
- Note) M5W Series indicates "19999" or "`9999".
(G)
※Higher than DC2A is using shunt for measuring current. ※Please notice a shunt and C.T are not included.
(I)
※Basically the 2nd part of shunt value is DC50mV. ● The D.P.M for measuring AC ampere has both AVG type SSR/
Power
Ex) Ordering D.P.M in case of DC10A of measuring ampere: and RMS type separately. controller
Select DC10A/50mVDC of shunt and 50mVDC/DC10.00A Because it is produced with AVG type, please mark the (J)
of D.P.M. model name accurately. Counter
(P)
I Switching
mode power
Hi supply
(Q)
C.T D.P.M Power supply Stepper
motor&
Driver&Controller
(R)
Load Low Graphic/
Logic
panel
L-55
M4Y/M4W/M5W/M4M Series
Ordering information
M 4 W W 1
No mark Indicator
Output
1P Single setting
2P Dual setting
※2
Y DIN W72×H36mm
Size ※2
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter
※1: When output specification of power converter is 0-10VDC, display value is maximum.
※2: M4Y, M5W are indicator.
※If output specification of Converter or power converter is DC4-20mA or 1-5VDC, please use scaling meter.
Application of connection
L1 L2 L3
P.T + ● The specification of measuring input indicated
in ordering information, is display value output
specification is 0-10VDC.
P.T ● When the output of transducer or converter is
Hi DC4-20mA or 1-5VDC, please use scaling meter.
Output : D.P.M Power supply
DC0-10V
C.T Low
C.T
Load (Transducer)
L-56
Digital Panel Meter
(B)
Features Fiber
optic
sensor
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or hold function(Except for M5W) (C)
Door/Area
● RMS/AVG value selection function(AC voltage) sensor
(H)
Temp.
controller
(I)
SSR/
M4Y / M4W / M4M M5W Power
NO controller
INPUT (F.S.) INPUT (F.S.)
1 0-10VDC / 1999 0-10VDC / 1999.9 (J)
Counter
Measuring input 2 0-10VAC / 1999 0-10VAC / 1999.9
DX DC Input option DC Input option
(K)
XX AC Input option AC Input option Timer
AC measuring
method No mark AVG value (L)
※1 Panel
R RMS value meter
No mark Indicator
Output (N)
1P Single setting output Display
unit
2P Dual setting output
※2
(O)
Y DIN W72×H36mm Sensor
Size ※2
controller
W DIN W96×H48mm
(P)
M DIN W72×H72mm Switching
mode power
Digit 4 1999(3½digit)
supply
(Q)
5 19999(4½digit) Stepper
Item motor&
Driver&Controller
M Meter
(R)
※1: AC measuring type of M5W only applies to RMS and it is not marked with "R" in the model name. Graphic/
Logic
※2: M4Y, M5W are indicator. panel
(S)
Field
network
device
Application of connection
(T)
Software
● Tacho Generator(T.G)
This generator makes a voltage in proportion to revolu-
M HI tion speed of motor. The D.P.M receives the voltage (U)
Other
T.G and displays the number of revolution and please check
D.P.M POWER
the specification of T.G.
LOW
● The specification of measuring input indicated in order-
Motor Tacho Generator Tacho/Speed meter ing information, is display value when output specifica-
tion is 0-10VDC and 0-10VAC. Different output specifi-
cation of tacho generator is optional.
L-57
M4Y/M4W/M5W/M4M Series
Ordering information
M 4 W DI X
Display scale
X Display range(Option)
Input
DI DC4-20mA(1-5VDC : Option※1)
No mark Indicator
Output
1P Single setting
2P Dual setting
※2
Y DIN W72×H36mm
Size ※2
W DIN W96×H48mm
M DIN W72×H72mm
Digit 4 1999(3½digit)
5 19999(4½digit)
Item
M Meter
※1: 1-5VDC of measuring input specification is available by option.
It will be a default value if there is no request for order.
※2: M4Y, M5W are indicator.
Application of connection
(+)
CONVERTER
HI
Temperature Sensor
Output:DC4-20mA Power supply
Pressure Sensor (1-5VDC: Option) D.P.M
LOW
(-)
(Transducer)
● The measurement input specification of ordering information, is an output specification of converter and DC4-20mA is the
standard specification. In case, the output of converter is 1-5VDC, it is customizable.
● DC voltmeter can be produced by requirement, in case, it is out of the 1-5VDC output specification.
L-58
Digital Panel Meter
DIN W96×H48mm, Digital panel meter for displaying power factor (A)
Photo
electric
sensor
Features (B)
Fiber
● Display indicator of power factor optic
sensor
(E)
Ordering information Pressure
sensor
M 4 W P (F)
Rotary
encoder
Measurement function
P Power Factor (G)
Connector/
Size Socket
W DIN W96×H48mm
Digit
4 9999(4digit) (H)
Temp.
Item controller
M Meter
(I)
Specifications SSR/
Connections
Power
controller
Model M4W-P
Measurement function Power factor INPUT 220VAC 110VAC (J)
50/60Hz 50/60Hz 0V Counter
Input DC4-20mA
Display -0.50 to 1.00 to +0.50 cosø 1 2 3 4 5 6 7 8
(K)
Power supply 110/220VAC 50/60Hz + - Timer
98
Min. 116 (U)
96 12 104 Other
45 + 00.6
Min. 52
92 +0.8
48
45
L-59