Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ANNEXURE - II

RAIN WATER CATCHMENT


a PLOT AREA IN ACRES
b PLOT AREA IN SQ MTR. 29999 m2
Terrace area 5350.00 m2
Paved area 2999.90 m2
Green area 4500.00 m2
Open area 17149 m2

SURFACE RUN OFF BEFORE PROJECT SOFT


A
DEVELOPMENT AREA
a INTENSITY OF RAIN FALL IN MM/HR 100
b TOTAL PLOT AREA SQ MTR. 29999
c RUN-OFF COEFFICIENT 0.30
d DISCHARGE IN CU MT/HR. 899.97
ROAD / GREEN /
SURFACE RUN OFF AFTER PROJECT Terrace
B HARD SOFT
DEVELOPMENT area
AREA AREA
a INTENSITY OF RAIN FALL IN MM/HR 100 100 100
b AREA UNDER OPEN IN SQ MTR. 5350.0 2999.9 21649.1
c RUN-OFF COEFFICIENT 0.85 0.70 0.30
d DISCHARGE IN CU MT/HR. 454.75 209.99 649.47
e TOTAL DISCHARGE IN CU MT/HR. 1314.22
INCREASE IN SURFACE RUN OFF AFTER
C 414.25
PROJECT DEVELOPMENT IN CU MT/HR.
D % INCREASE IN SURFACE RUN OFF 46.03
E Percolation wells
Cal for One Hr. Storage
Total Discharge in One Hr. CUM 414.246 m3
Percolation rate 0.010 m/hr
Total percolation area 4.142 m2
Dia of one pit 0.600 m
Area of one 0.283 m2
Depth of Pit in Mtr 20
Nos. of Pit 14.6583864

F Storm water drain calculations


Run-off Q 899.97 m3/hr
Run-off 0.24999167 m3/sec
Q = A x V, where V = 1.5 m/sec
A= Q/V
Area of storm water drain, A 0.16666111 m2
Considering Width, w = 0.6 m 0.6 m
The depth of storm water drain, d 0.27776852 m
Considering free board of 75 mm, i.e. 0.075 m, total
0.35276852 m
depth

Page 8