Foundation Plan Trussed Rafter Layout Floor Plan: D IA GO NAL
Foundation Plan Trussed Rafter Layout Floor Plan: D IA GO NAL
Foundation Plan Trussed Rafter Layout Floor Plan: D IA GO NAL
3330 3330
327
327
327
3.75mØ SQUARE TWIST NAILS, 30mm LONG,
THE USE OF FACTORY
MIXED MORTAR (HANSON FIXED TO U/S OF TRUSSES BOTTOM CHORD.
DASHED LINES INDICATE
RWP RWP RWP PREMIX MORTAR OR SIMILAR) RWP BRACING TIMBER TO BE Min. 100 X 25mm
ADDITIONAL FOUNDATIONS IN ACCORDANCE WITH
BS EN 998 (SPECIFICATION FOR 5 NO. LONGITUDINAL
1589
1589
REQUIRED FOR USE WITH
935
935
MORTAR FOR MASONRY – PART 2).
SUSPENDED FLOOR SLABS ONLY SHOULD BE USED.
TIES OCCURING
SEE G01.G02[DET]01 FOR DETAILS THROUGHOUT THE
ROOF LENGTH
70
52
327
327
D IA
2618
2618
RS RS/CS RS * DENOTES WALL PLATES
GO
STRAPPED DOWN TO
* *
NA
LAYOUT FOR
856
856
856
856
MESH SIZES INDICATED ARE DOOR POSITIONS
327
327
NAILED TO EACH TRUSS WITH 3.35 x
75 LONG GALVANISED WIRE NAILS
150MM
*
6216
6216
*
327
327
1 NO. LAYER B385
UNDER RAFTER DIAGONAL
OR BEAM AND
1451
1451
BRACING LAP JOINTS TO BE
BLOCK SPAN
TAKEN OVER 2 TRUSSES
C. C.
BRACING KEY
BRICKS: DENOTES CEILING BRACING (100 x 25mm)
3771
3771
WALLS, PIERS: CLAY BRICKS
327
327
2730
RS RS/CS RS
1451
WALLS USING 2NO. 20x3
STAINLESS STEEL TIES AT 300
CRS VERTICALLY 1450 x 150 x 30 x 5MM
GALVANISED M.S.
DOOR FRAME BEHIND OPENING IF
RESTRAINT STRAPS
REQUIRED
AT MAX. 2000MM CTS.
215
215
215
215
RS = ROOF STRAP
102 x 102 x 8MM M.S ANGLE FOR
CS = CEILING STRAP
BRICKWORK GABLE ABOVE RIDGE LINE
3330 3330
35° PITCH TO MAIN ROOF
FOUNDATION PLAN
CONCRETE SPECIFICATION
FLOOR PLAN TRUSSED RAFTER LAYOUT
BRACING OF TRUSSED RAFTERS TO BS 5268: PART 3: 1985 BY SUPPLIER.
SPECIFYING OF CONCRETE TO BS 5328: PART 1: 1991 MIXES AS FOLLOWS:- PLEASE NOTE CLOSE ATTENTION TO THE MASONRY
CONSTRUCTION AND THE SPECIFICATION, TRUSS MANUFACTURER TO CONFIRM DETAILS OF DESIGN & BRACING
( NON-HAZARDOUS CONDITIONS ) DESIGN METHODS AND RELEVANT TESTS. E.G. AND THAT ENDBEARING STRESSES TO C16 TIMBER WALLPLATE AND 3.5N/MM²
CONCRETE STRIP FOUNDATIONS & TRENCHFILL = ST2 MIX (GEN 1) PERIODIC CLOSE SUPERVISION BLOCKWORK ARE NOT EXCEEDED, ANY VARIATION FROM THIS DESIGN AND SPECIAL
OF BRICKLAYERS, CAREFUL POST CONSTRUCTION
GROUND BEARING FLOORS NOT REINFORCED = ST3 MIX (GEN 2) INSPECTION OF ALL JOINTS ETC, SHOULD REQUIREMENTS ARE TO BE CONFIRMED BY THE TRUSS MANUFACTURER.
GARAGE FLOORS NOT REINFORCED = ST4 MIX (GEN 3) BE ADHERED TO.
REINFORCED CONCRETE FLOOR SLABS = ST5 MIX ( RC35 )
Revisions:
35° 35° Rev Date Drawn Checked
35° 35°
A 14.05.12 14.05.12 GTD
2100 (28 COURSES)