Construction Applications CNAUSA-660RB1

These cables are used in the transmission of RF signals and power for
• Physical foaming (gas injected) foam polyethylene insulation
voice, data and video applications. Used oninstallations as per National
• Bonded to central conductor Electrical Code (NEC) and NFPA 70. Also used for satellite cable installation.
• Inner shield laminated tape bonded to dielectric CENTER CONDUCTOR
Copper covered steel
• Aluminum braid
CENTER CONDUCTOR
• Polyvinylchloride jacket BONDED TO THE DIELECTRIC
Withstanding a minimum
force of 5 lbs over a length of
2’’ in compliance with SCTE
Jacket 74 2011
Center Inner Outer
Dimensions Dielectric Braid Messenger DIELECTRIC
Conductor Shield Shield Single Tri Foamed polyethylene closed
CORPORATE HEADQUARTERS Braid Shield cell structure

Characteristics Units ASTM A641


Cablenetwork Associates, Inc. ASTM B 869 ASTM D 1248 UL 1581
4800 N Federal Highway Suite E300 Class 1
Boca Raton, FL. 33431 Diameter in 0.040 0.180 0.187 0.209 0.214 0.273 0.278
Tel: (954) 312-1200 FIRST SHIELD (APA)
Electrical Conductivity Aluminum/Polymer/Aluminum
sales@cablenetwork.net % 21 Tape flap is attached to ensure
perfect connector insertion
Thickness in 0.0032 0.0032
PRODUCTION PLANTS

CNA Technology, LLC Mechanical Characteristics SECOND SHIELD


220 Industrial Boulevard
Maximum Attenuation @ 20ºC (68ºF) Outer shield of braided
Minimum breaking strength of messenger aluminum wires 34 AWG
Greenville, NC 27834
Tel: (252) 628-8268
sales@cablenetwork.net Frequency (MHz) dB/100m dB/100ft
Electrical Characteristics
THIRD SHIELD (APA)
Cablenetwork Argentina SRL Nominal Imperance 5 0.58 1.90 APA laminated tape shield.
Buenos Aires, San Martín
75 ohms
Minimum separation force of
Calle 113 (ex Alvear) Nº 2560 Nominal Velocity of Propagation 85% 55 5.25 1.60 the tape jacket 3 lbs per foot
Tel: (54) 11 4755-5200 cable
ventas.ar@cablenetwork.net Min Structural Return Loss 5 - 1000 MHz -20 dB 211 10.00 3.05

CNA México S. de R.L de C.V. 300 11.64 3.55


Eje 5 Sur Nº36, Col. Paseos de Standards JACKET
Churubusco México D.F. 450 14.43 4.40 Fire resistant black PVC

Tel: (52) 55 5640-7287


ANSI/SCTE 74 2003 Spec. for Braided 75 Ω Flexible RF Coax Drop Cable
ventas.mx@cablenetwork.net 550 16.08 4.90
UL 444 Communications Cables
UL 1581 Cables and Flexible Cords 600 16.73 5.10
CNA México
Avenida USA # 292. 750 18.54 5.65
UL 1655 Community Antena Television Cable
Parque Industrial Tres Naciones.
San Luis Potosí, SLP. México. 1000 21.49 6.55
C.P. 78395 Construction Color
ventas.mx@cablenetwork.net 1200 25.30 7.71
B - Black 1450 27.10 8.26
R - Round
W - White
M – Messenger
G - Any color different than Black or White 1800 33.36 9.25
Jacket color and sequential print 2200 33.09 10.09
B= black jacket sequential print in m/ft
2500 35.50 10.82
W= white jacket sequential print in m/ft
Packaging 2750 37.30 11.37
1= Coils 305m/1000ft 3000 39.10 11.92
2= Coils 500m/1640ft
3= Custom length
4= Reel boxes 305m/1000ft

You might also like