Technical Catalogue
Warmly welcome to Paradise Cables Ltd (PCL), one of the leading manufacturers' of
Electric Cables in Bangladesh.
We started our Journey in 1989, and have grown steadily ever since. PCL now offers the
complete range of Electric Cables up to 33KV. Our motto is to be first preferential partner
for all your Cable requirement.
As a prestigious BASEC (British Approvals Services for Cables) approved manufacturer &
supplier we are operating to the highest international standards in Quality. As regards
Environmental and Health & Safety Management, we provide customers with value for
money in Local and International markets. Our recent unprecedented achievement of
Product Quality Certificate from KEMA ( A testing and certification body of Electrical
Engineering Products) a globally renowned accreditation body of Netherland, has
enormously enhanced the image of our organization transforming its status to world class
cable manufacturer. The strength of the Certificate has further extended our Global
marketing arena.
PCL is committed to face the Global challenge and to that end in view BMRE is almost a
continual phenomenon. We cordially welcome you to our site and look forward to serve
you with your cable requirements.
Our product mix is huge and the product ranges from house wiring cables up to and including
medium voltage cables of 36KV and Aluminium Conductors up to 132KV. We also produce all
types of Telecommunication, Electronic and Instrumentation Cables. Paradise Cables Ltd. is the
pioneer of CCV (Catenary curing and Vulcanizing) with on-line Nitrogen dry curing plant in
Bangladesh. We follow the standards like IEC, ASTM, BS, VDE, BDS etc. for our products. We use
electrolytically refined oxygen free cathode copper of 99.99% purity ensuring the quality of cables
as international standard. In addition, there exists a modern computerized laboratory equipped
with latest equipment of USA and German origin to determine the electrical, mechanical, physical
and chemical properties of the materials and the products. By virtue of consistent quality of
products and implementation of quality management system, our company has earned the name
and fame throughout Bangladesh and even beyond. Our product demand is continuously
increasing considerably.
It is worth mentioning that to keep pace with the growing global challenge; BMRE (Balancing,
Modernization, Rehabilitation and Expansion) is ongoing phenomenon of this organization. We
are proud to mention that our organization is the only cable industry in Bangladesh which has
successfully achieved the prestigious BASEC (British Approvals Service for Cables) QMS and
Product Certification License. Moreover, we have successfully received Product Quality Certificate
of KEMA (A testing and certification body of Electrical Engineering Products) a globally
renowned accreditation body of Netherland. This glorious achievement has paved the way to
expand our Export Market in almost all the countries of the World. We have also started marketing
our products in Middle East and UK through our own sales outlet in Dubai. A scheme to expand
our market in Canada and USA is in the final stage. We are enlisted Supplier of GE Energy, USA, a
top leader in Power Generation arena across the world.
Further, based on strength of BASEC's QMS certificate we have got the access to export our
products to 24 countries including UK, USA, Australia, South Africa, UAE, China and India.
Above all, we express our firm commitment to provide quality cables to the customers at large
and earn their ultimate satisfaction.
ISO 9001:2008
Page
- Product Range 8
- Flow chart 9
- Designation Code 10
- Operating conditions 11
LOW VOLTAGE CABLES
- PVC insulated Single core general purpose cables 17
- PVC insulated and sheathed single / multi core general purpose cables 18
- PVC insulated and sheathed Flat / with circuit protective conductor cables 20
- Flexible PVC cables 23
- PVC insulated single / Multi core, unarmoured / armoured LT power cables 27
- XLPE insulated single / Multi core, unarmoured / armoured LT power cables 32
- Concentric Conductor Three core PVC / XLPE insulated Frequency conversion cables 37
- Co-axial cables 39
- Telephone cables 40
- Fire alarm signal cables 41
CONTROL CABLES
- PVC insulated Non-shield / Shield and Unarmoured / Armoured control cables 45
- XLPE insulated Non-shield / Shield and Unarmoured / Armoured control cables 48
- Flexible Unscreened connection & control cables 51
- Flexible Screened control cables 52
MEDIUM VOLTAGE CABLES
- 3.6/6 (7.2)KV Single / Three core and Un-armoured / Armoured HT power cables 57
- 6/10 (12)KV Single / Three core and Un-armoured / Armoured HT power cables 59
- 8.7/15 (17.5)KV Single / Three core and Un-armoured / Armoured HT power cables 61
- 12/20 (24)KV Single / Three core and Un-armoured / Armoured HT power cables 63
- 18/30 (36)KV Single / Three core and Un-armoured / Armoured HT power cables 65
SPECIAL CABLES
- PVC /XLPE insulated. Multi conductor and Unshielded / overall Shielded Instrumentation cables 69
- PVC /XLPE insulated. Multi-Pair and Unshielded / overall Shielded Instrumentation cables 70
- PVC /XLPE insulated. Multi-Triad and Unshielded / overall Shielded Instrumentation cables 71
- PVC /XLPE insulated. Multi Pair/Triad and Individual / overall Shielded Instrumentation cables 72
- Low Capacitance Instrumentation cables 73
- Data Transmission Cables 74
- Industrial Electronic Cables 75
- Local Area Network Cables 76
- Computer Cables 77
- Submersible Pump Cables 78
- PVC/PE Insulated Drop Wires 79
- PVC insulated Service Drop wires 80
- Fire Survival Cables 81
- Special Flat Flexible Cables 82
ALUMINUM OVER HEAD CONDUCTORS
- AAC Conductors 86
- PVC insulated AAC conductors 87
- XLPE insulated Medium Hard Drawn Conductors 87
- ACSR Conductors 88
- Pre-assembled XLPE insulated Aluminum / ACSR Conductors as Duplex / Quadruplex conductors 90
TECHNICAL INFORMATION 93
ISO 9001:2008
WIRE DRAWING
ANNEALING
TEST ON WIRE
CONDUCTOR STRANDING
TEST ON CONDUCTOR
STOCK
UNARMORED
GALVANISED STEEL
WIRE /STRIP/TAPE ARMOURING STOCK
PVC COMPOUND
TEST ON COMPOUND
PACKING
DISPATCH
STOCK
ISO 9001:2008
ISO 9001:2008
Low voltage cables are manufactured with PVC, PE and XLPE insulations for various applications
within voltage range from 300V to 1000V category.
APPLICATIONS:
Extensively used for power distribution, control, instrumentation, communication, signaling and
data transmission applications
PVC, as insulation and sheath compounds, has the following superior features:
- Strong and made for easy processing
- Resistant to water, moisture, oils and chemicals
- PVC black compounds can resist ultraviolet degradation
- Specially formulated PVC is flame retardant and reduces emission of halogens and smoke.
PVC INSULATION
STRANDED Cu/Al CONDUCTOR
XLPE INSULATION
CONDUCTORS
The conductor is made either of Copper or Aluminum as per the requirement by following
standard specifications. While designing, flexibility and compactness are carefully worked out by
choice of wires, drawn bright and smooth. Under strict supervision, stranding and compacting is
carried out by skilled operators to bring out a smooth surface so as to ensure minimum stress
development on the surface of the conductor.
INSULATION
High quality PVC base compound is used for voltages up to 1.2 KV PVC cables, high quality
unfilled PE compound is used for processing of low voltage (up to 500V), data processing and
communication cables and high quality Cross Linked Polyethylene unfilled compound is used for
low voltage and High voltage cables also.
ISO 9001:2008
LAYING UP
In multicore cables, cores are laid up as per the colour scheme and interstices are filled up
wherever necessary to make the laid up cable circular.
INNER SHEATH
For all cables having two or more cores and single core armoured cables, a common covering is
applied over single core or the laid up cores either by extruded sheath of PVC Compound or
wrapping of thermoplastic or proofed tapes.
ARMOURING
For multicore cables, wire armouring is applied over the inner sheath, where the fictitious
diameter over the inner sheath does not exceed 15mm. The diameter above this, armouring
can be applied by either round steel wires or flat steel wires or double steel tapes. However,
non magnetic Aluminum wire armouring is applied over single core cables.
OUTER SHEATH
Extruded over armour : in armoured cables
Over Inner sheath : in multicore unarmoured cables
Over Insulation : in single core cables
It is always kept Black in colour for outdoor exposure. Any other colour can be provided for
indoor use. Normally tough outer sheath of Heat resisting PVC compound (Type ST2) is
extruded over all the XLPE cables. In special cases when required by the customers, fire
resistant (FR) or fire resistant low smoke (FRLS) PVC outer sheath cables are also supplied.
CORE IDENTIFICATION
Cores are identified by the colour scheme of insulation. The following colour scheme is
normally adopted for power cables as per IEC specification. Any other colour scheme also
can be offered as per other international standards like BS, VDE, etc. on request.
1 Core : Red, Yellow, Blue, Brown, Green, Black and Yellow-Green
2 Cores : Red and Black
3 Cores : Red, Yellow and Blue
4 Cores : Red, Yellow, Blue and Black
5 Cores : Red, Yellow, Blue, Black and Grey
For cables having more than 5 cores, black or white coloured cores with no. printing will be
provided. Communication and data processing cables are having their own colour schemes.
ROUTINE TESTS
The following tests constitute Routine Tests which are carried out on each and every length of
cable as per relevant specification.
" Conductor Resistance Test
" High Voltage Test
TYPE TESTS
These tests are carried out on samples taken from each production lot as per relevant
specification. They are carried out to prove conformity as regards the general qualities and
design to the of particular type of cables
ACCEPTANCE TESTS
These tests are carried out as per relevant specification in the presence of the concerned
Inspecting Authority for Testing, Approval and Release of material offered for inspection.
ISO 9001:2008
Solid conductor! : (Class-1)! : H07V-U! BS 6004:2004/BDS-900
Stranded conductor!: (Class-2)! : H07V-R BYM! VOLTAGE GRADE: 450/750V
Flexible conductor! : (Class-5)! : H07V-K! Temp. Range: -20°C to +70°C
APPLICATION: Used for fixed installation for the purpose of lighting in residential and commercial
buildings, inside appliances, switchgear and control gear.
CONSTRUCTION: Annealed copper/Aluminium conductor as per IEC-228, (of class-1 solid; class-2
stranded, class-5 flexible) and PVC insulated as per BS-6746, Colour coded and PVC sheathed.
Nominal Class of Insulation sheath Approx. Approx. Weight Enclosed in Clipped to a
area of Conductor thickness thickness O.D of Cable conduit @ 35°C surface or on a
Conductor cable tray @ 35°C
Cu AL Cu AL Cu AL
mm2 mm mm mm kg/km kg/km amps amps amps amps
1.0 1 0.6 0.8 3.93 25 – 13 – 16 –
1.3 2 0.7 0.8 4.60 34 26 15 10 19 12
1.5 1 0.7 0.8 4.38 32 – 16 – 20 –
1.5 2 0.7 0.8 4.73 33 27 16 11 20 13
1.5 5 0.7 0.8 4.50 33 – 16 – 20 –
2.0 2 0.7 0.8 4.97 44 32 20 13 25 15
2.5 1 0.8 0.8 4.98 45 – 22 – 28 –
2.5 2 0.8 0.8 5.45 46 36 22 15 28 18
2.5 5 0.8 0.8 5.21 46 – 22 – 28 –
3.0 2 0.8 0.8 5.42 60 41 26 17 31 20
4.0 2 0.8 0.9 5.95 73 48 30 20 37 24
4.5 2 0.8 0.9 6.13 81 52 32 21 39 25
6.0 2 0.8 0.9 6.52 96 59 38 25 47 31
7.0 2 0.8 0.9 6.76 107 64 42 27 51 33
10 2 1.0 0.9 7.85 147 84 52 34 63 41
14.5 2 1.0 1.0 8.89 206 113 65 40 79 50
16 2 1.0 1.0 9.10 218 117 70 45 85 55
25 2 1.2 1.1 11.02 328 169 91 60 110 72
35 2 1.2 1.1 12.25 432 211 112 73 136 88
ISO 9001:2008
Solid conductor! : (Class-1)! : H07V-U! BS 6004:2004/BDS-900
Stranded conductor!: (Class-2)! : H07V-R BYM! VOLTAGE GRADE: 450/750V
! ! ! Temp. Range: -20°C to +70°C
APPLICATION: Used for fixed installation for the purpose of lighting in residential and commercial
buildings, inside appliances, switchgear and control gear.
CONSTRUCTION: Annealed copper/Aluminium conductor as per IEC-228, (of class-1 solid; class-2
stranded) and PVC insulated as per BS-6746, Colour coded and PVC sheathed.
Nominal Class of Insulation sheath Approx. Approx. Weight Enclosed in Clipped to a
area of Conductor thickness thickness O.D of Cable conduit @ 35°C surface or on a
Conductor cable tray @ 35°C
Cu AL Cu AL Cu AL
mm2 mm mm mm kg/km kg/km amps amps amps amps
1.0 1 0.6 1.2 8.43 106 – 11 – 12 –
1.5 1 0.7 1.2 9.40 139 – 15 – 16 –
1.5 2 0.7 1.2 10.16 142 111 15 10 16 11
2.5 1 0.8 1.2 10.70 195 – 20 – 22 –
2.5 2 0.8 1.2 11.70 198 149 20 14 22 15
4.0 2 0.8 1.2 12.36 268 193 27 19 30 21
6.0 2 0.8 1.4 13.99 386 273 33 23 37 26
10 2 1.0 1.4 16.87 590 400 46 32 51 36
16 2 1.0 1.4 19.14 856 553 58 38 67 44
25 2 1.2 1.6 23.25 1272 794 66 43 77 50
35 2 1.2 1.6 25.91 1685 1023 81 53 90 59
APPLICATION: These cables are used in dry or damp locations for fixed installation. Can
be used for installation in walls, on boards or embedded in plaster.
CONSTRUCTION: Plain annealed copper conductor as per IEC-228, PVC insulated, two or
three cores laid parallel and PVC sheathed as per BS-6746, normally in GREY colour.
No. of Cores Nom. Area of Class of Thickness Over all Approx. Current Rating
conductor conductor of insulation diameter Weight
of the Cable Single Phase Three Phase
No. mm2 mm mm Kg/km amps amps
ISO 9001:2008 Parallel Cords: H05VVH2-F BDS 900 - BS-6500 & VDE-0250 BDS-IEC 227-2002
Circular Cords: H05VV-F NYMHY
APPLICATIO N: These cables are useful for medium duties in domestic premises,
Kitchens, offices. Can be used for connecting washing machines, refrigerators, cooking
and heating appliances etc,.
CONSTRUCTION: Annealed flexible copper stranded conductor (as per class 5 of IEC
228), PVC insulated, colour coded, cores twisted and PVC outer sheathed (as per BS
6746), normally round cables in white colour and flat cables in Grey colour.
TECHNICAL DATA: Temperature range: -15°C to +70°C
Working voltage! : 300/500 volts R.M.S.
Core identification! : Two core : Blue & Brown
Three cores! : Green/Yellow, Blue & Brown
Four cores! : Green/yellow, Black, Blue & Brown
Five cores! : Green/Yellow, Black, Blue, Brown & Grey
Sl. Cores Cable Size Strands/dia. Insulation Sheath Approx. Approx. Current Rating
No. No. Thickness Thickness O. D. Weight In conduit In open tray
at 35°C at 35°C
No. mm2 No./mm mm mm mm Kg/km amps. amps.
1 2C 0.5 16/0.2 0.6 0.8 6.1 50 3 4
2 2C (Flat) 0.5 16/0.2 0.6 0.8 6.2x3.9 43 3 4
3 2C 0.75 24/0.2 0.6 0.8 6.5 61 6 7
4 2C (Flat) 0.75 24/0.2 0.6 0.8 6.6x4.1 50 6 7
5 2C 1.0 32/0.2 0.6 0.8 6.8 70 10 11
6 2C (Flat) 1.0 32/0.2 0.6 0.8 6.9x4.3 59 10 11
7 2C 1.5 30/0.25 0.7 0.8 7.7 91 15 16
8 2C 2.5 50/0.25 0.8 1.0 9.3 139 20 21
9 2C 4.0 56/0.3 0.8 1.1 10.5 192 25 26
ISO 9001:2008
APPLICATION: These cables are suitable for all electrical installations in dry or humid
locations, under industrial conditions. Applications include machine tool manufacture,
power stations, heating and air conditioning installations etc.
CONSTRUCTION: Annealed plain copper as per class-5 of IEC-228, PVC insulated, colour
coded, laid-up and PVC outer sheathed as per BS-6746, coloured normally in Black. other
sheath colours also can be supplied on request.
TECHNICAL DATA: Temperature range! : -15°C to +70°C
Working Voltage! ! ! : 450 / 750 V. R.M.S
Core Identification: Two Cores!! ! : Blue & Brown
three cores! ! ! ! : Green/Yellow, Blue, & Brown.
Four cores! ! ! ! : Green/Yellow, Black, Blue & Brown
ISO 9001:2008
BDS 899 BS 6500 & BS 2004(old)
DESCRIPTION: Plain annealed flexible copper conductors, PVC insulated and twisted
cables Not to be use in 440v circuits.
II) Type: Flexible Twisted Twin cables
Cross sectional No. & size No. & size Nominal Overall App. Weight Current rating at35°C
area of of wires of wires thickness diameter of cable ambient temp.
conductor of insulation of each core in metal conduit In air
mm² No./mm No./mm mm mm Kg/km amps amps
2x0.40 14/0.193 14/0.0076 0.5 2.0 15 2 3
2x0.65 23/0.193 23/0.0076 0.5 2.2 20 5 6
2x1.20 40/0.193 40/0.0076 0.6 2.6 31 11 13
2x2.00 70/0.193 70/0.0076 0.7 3.2 50 16 18
DESCRIPTION: Plain annealed flexible copper conductors, PVC insulated and PVC sheathed
Flat cables. Not to be use in 440v circuits.
III) Type: Flexible Flat Twin Cables
Cross sectional No. & size No. & size Nominal Thickness Overall App. Weight Current rating at35°C
area of of wires of wires thickness of sheath dimension of cable ambient temp.
conductor of insulation of cable in metal conduit In air
mm² No./mm No./mm mm mm mm Kg/km amps amps
2x0.40 14/0.193 14/0.0076 0.5 0.6 3.2x5.2 29 2 3
2x0.65 23/0.193 23/0.0076 0.5 0.6 3.4x5.5 37 5 6
DESCRIPTION: Plain annealed flexible copper conductors, PVC insulated, laid up and PVC
sheathed round cables. Not to be use in 440v circuits.
III) Type: Flexible Two core Cables
Cross sectional No. & size No. & size Nominal Thickness Overall App. Weight Current rating at35°C
area of of wires of wires thickness of sheath diameter of cable ambient temp.
conductor of insulation of cable in metal conduit In air
mm² No./mm No./inch mm mm mm Kg/km amps amps
2x0.40 14/0.193 14/0.0076 0.5 0.6 5.1 38 3 4
2x0.65 23/0.193 23/0.0076 0.5 0.6 5.6 48 6 8
2x1.20 40/0.193 40/0.0076 0.6 0.8 6.8 71 13 16
2x2.00 70/0.193 70/0.0076 0.7 0.9 8.1 108 18 20
2x3.00 110/0.193 110/0.0076 0.8 1.0 9.5 146 24 26
DESCRIPTION: Plain annealed flexible copper conductors, PVC insulated, laid up and PVC
sheathed round cables. Not to be use in 440v circuits.
IV) Type: Flexible Three core Cables
Cross sectional No. & size No. & size Nominal Thickness Overall App. Weight Current rating at35°C
area of of wires of wires thickness of sheath diameter of cable ambient temp.
conductor of insulation of cable in metal conduit In air
mm² No./mm No./inch mm mm mm Kg/km amps amps
3x0.40 14/0.193 14/0.0076 0.5 0.6 5.6 48 3 4
3x0.65 23/0.193 23/0.0076 0.5 0.6 6.0 58 6 8
3x1.20 40/0.193 40/0.0076 0.6 0.8 7.3 85 13 16
3x2.00 70/0.193 70/0.0076 0.7 0.9 8.7 126 18 20
3x3.00 110/0.193 110/0.0076 0.8 1.0 10.0 178 24 26
DESCRIPTION: Plain annealed flexible copper conductors, PVC insulated, laid up and PVC
sheathed round cables. Not to be use in 440v circuits.
V) Type: Flexible Four core Cables
Cross sectional No. & size No. & size Nominal Thickness Overall App. Weight Current rating at35°C
area of of wires of wires thickness of sheath diameter of cable ambient temp.
conductor of insulation of cable in metal conduit In air
mm² No./mm No./inch mm mm mm Kg/km amps amps
4x0.40 14/0.193 14/0.0076 0.5 0.6 6.1 56 3 4
4x0.65 23/0.193 23/0.0076 0.5 0.6 6.5 69 6 8
4x1.20 40/0.193 40/0.0076 0.6 0.8 8.1 101 13 16
4x2.00 70/0.193 70/0.0076 0.7 0.9 9.7 158 18 20
4x3.00 110/0.193 110/0.0076 0.8 1.0 11.2 228 24 26
ISO 9001:2008 DESCRIPTION: Copper/Aluminum Conductor, PVC Insulated, Cores laid up, PVC inner sheathed, Unarmoured/AL. Round wire
armoured/AL.Double Tape armoured & PVC Outer Sheathed cables.
STANDARD: BDS-IEC-60502 (1) VDE-0271 BS- 6346
APPLICATION: Can be used indoors or outdoors, in cable ducts or Tray or under ground in power switching stations, in local
distribution systems, Industrial plants, and in commercial buildings
No. of cores = 1C Temperature Range = -15°C to +70°C Voltage Grade = 0.6/1( 1.2) KV
Nom. Nom. UNARMOURED AL. ROUND WIRE ARMOURED AL. DOUBLE TAPE ARMOURED CURRENT RATING
size thick NYY / YY / AYY NYRaY / YRaY / AYRaY NYBaY / YBaY / AYBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size of Nom. Approx. Approx.
thick of Overall Weight armour thick overall Weight armour thick overall Weight 30°C in ground 35°C in air
outer diameter of cable wire ofouter diameter of cable Tape of outer diameter of cable
sheath CU AL sheath CU AL sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
1x1.5rm 0.8 1.4 6.2 56 1.25 1.8 10.5 155 27 22
1x2.5rm 0.8 1.4 6.6 70 1.25 1.8 11 175 36 30
1x4rm 1 1.4 7.6 97 72 1.25 1.8 11.9 214 190 47 37 39 31
1x6rm 1 1.4 8.1 121 85 1.25 1.8 12.5 246 209 59 48 50 41
27 1x10rm 1 1.4 8.8 165 103 1.25 1.8 13.2 299 237 78 60 69 53
1x16rm 1 1.4 9.8 231 132 1.25 1.8 14.2 378 279 100 78 94 73
1x25rm 1.2 1.4 11.5 337 183 1.25 1.8 15.8 505 350 0.5x20 1.8 14.6 430 300 130 101 125 97
1x35rm 1.2 1.4 12.6 442 226 1.25 1.8 16.9 624 407 0.5x20 1.8 15.7 530 320 155 120 160 124
1x50rm 1.4 1.4 14.1 600 291 1.25 1.8 18.4 801 492 0.5x20 1.8 17.2 702 350 185 144 195 152
1x70rm 1.4 1.4 15.7 804 371 1.25 1.8 20 1025 592 0.5x20 1.8 18.8 915 485 225 175 245 191
1x95rm 1.6 1.5 18.1 1084 496 1.25 1.8 22.2 1325 738 0.5x20 1.8 21.2 1208 628 270 210 300 233
1x120rm 1.6 1.5 19.7 1337 595 1.6 1.8 24.5 1652 910 0.5x30 1.8 22.6 1447 775 310 240 350 272
1x150rm 1.8 1.6 21.6 1654 726 1.6 1.8 26.2 1985 1057 0.5x30 1.8 34.8 1826 900 350 270 405 314
1x185rm 2 1.7 23.8 2025 880 1.6 1.9 28.6 2400 1255 0.5x30 1.8 27 2208 1068 390 302 460 458
1x240rm 2.2 1.8 26.6 2598 1112 1.6 2 31.4 3013 1528 0.5x30 1.8 29.8 2805 1318 450 349 555 431
1x300rm 2.4 1.9 29.6 3239 1383 1.6 2.1 34.5 3699 1843 0.5x30 1.9 31.2 3510 1615 515 386 640 448
1x400rm 2.6 2 33 4230 1755 2 2.2 38.7 4839 2364 0.5x40 2 36.6 4535 2060 585 439 770 540
1X500rm 2.8 2.1 37 5350 2135 2 2.3 42 5725 2270 0.5x40 2.1 40.6 5570 2235 680 510 900 630
1x630rm 2.8 2.2 40 6631 2620 2.5 2.5 46 7025 2760 0.5x40 2.2 43.7 6830 2690 800 600 1030 721
1x800rm 2.8 2.3 46 8341 3195 2.5 2.6 52 8920 3465 0.5x40 2.3 49.6 8610 3340 945 708 1160 812
1x1000rm 3 2.4 51 10362 3890 2.5 2.8 58 11020 4250 0.5x40 2.4 55 10691 3890 1090 821 1310 917
ISO 9001:2008 DESCRIPTION: Two core Copper/Aluminum Conductor, PVC Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round Steel wire
armoured/Flat Steel wire armoured and PVC outer sheathed cables.
STANDARD: BDS-IEC-60502 (1) VDE-0271 BS- 6346
APPLICATION: Can be used indoors or outdoors, in cable ducts or tray or under ground in power switching stations, in local dtribution
systems, Industrial plants, and commercial buildings
No. of cores = 2C Temperature Range = -15°C to +70°C Voltage Grade = 0.6/1( 1.2) KV
Nominal UNARMOURED STEEL ROUND WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size Nom. NYY / YY / AYY NYRaY / YRaY / AYRaY NYFGY / YFGY / AYFGY
of thick
conductor Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
of thick Overall Weight armour thick overall Weight of thick overall Weight 30°C in ground 35°C in air
Insulation of outer diameter of cable wire ofouter diameter of cable armour of outer diameter of cable
sheath sheath strip sheath
28 mm² mm mm mm
CU
kg/km
AL
kg/km mm mm mm
CU
kg/km
AL
kg/km mm mm mm
CU
kg/km
AL
kg/km
CU
amps
AL
amps
CU
amps
AL
amps
2x1.5rm 0.8 1.8 10.3 146 0.9 1.8 14.2 385 25 19
2x2.5rm 0.8 1.8 11.1 184 0.9 1.8 15 444 34 27
2x4rm 1 1.8 13.1 261 211 0.9 1.8 17.7 664 613 45 35 35 28
2x6rm 1 1.8 14.2 327 251 1.25 1.8 18.8 762 686 56 45 45 37
2x10rm 1 1.8 15.6 436 310 1.25 1.8 202 913 786 74 57 62 48
2x16rm 1 1.8 19.6 697 426 1.25 1.8 22.9 1275 1073 0.8X4 1.8 21.9 1087 885 96 75 84 65
2x25sm 1.2 1.8 23 996 680 1.6 1.8 26.1 1676 1360 0.8X4 1.8 25.1 1460 1144 125 97 110 86
2x35sm 1.2 1.8 25.1 1271 830 1.6 1.9 25.5 2034 1593 0.8X4 1.8 27.3 1786 1344 149 117 140 109
2x50sm 1.4 1.8 28.1 1689 1058 1.6 2 31.8 2565 1983 0.8X4 1.9 30.6 2288 1657 178 138 169 132
2x70sm 1.4 2 31.7 2247 1363 2 2.1 36 3465 2582 0.8X4 2 34 2907 2023 216 168 213 166202
2x95sm 1.6 2.1 36.3 2998 1799 2 2.3 40.8 4415 3216 0.8X4 2.2 39.2 3852 2653 259 201 261 236
2x120sm 1.6 2.2 39.6 3673 2158 2 2.4 44.1 5217 3703 0.8X4 2.3 42.5 4607 3092 298 230 304 273
2x150sm 1.8 2.3 43.4 4494 2601 2.5 2.6 49.1 6643 4750 0.8X4 2.4 46.3 5519 3626 336 259 352 330
2x185sm 2 2.4 47.8 5502 3167 2.5 2.7 53.6 7869 5533 0.8X4 2.6 51 6661 4326 375 289 400 375
ISO 9001:2008 DESCRIPTION: Three core Copper/Aluminum Conductor, PVC Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round Steel
wire armoured/Flat Steel wire armoured and PVC outer sheathed cables
STANDARD: BDS-IEC 60502 (1) VDE-0271 BS- 6346
APPLICATION: Can be used indoors or outdoors, in cable ducts or tray or under ground in power switching stations, in local
distribution systems, Industrial plants, and commercial buildings
No. of cores =3C Temperature Range = -15°C to +70°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size of thick NYY / YY / AYY NYRY / YRY / AYRY NYFGY / YFGY / AYFGY
conductor of
Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight armour thick of overall Weight of thick overall Weight 30°C in ground 35°C in air
of outer diameter of cable wire outer diameter of cable armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
3x1.5rm 0.8 1.8 108 168 0.9 1.8 14.7 420 22 17
3x2.5rm 0.8 1.8 11.7 216 0.9 1.8 15.6 490 30 24
3x4rm 1 1.8 13.8 311 235 1.25 1.8 18.4 736 660 38 31 32 25
3x6rm 1 1.8 15 396 282 1.25 1.8 19.6 855 742 48 39 41 34
29 3x10rm 1 1.8 16.5 541 352 1.25 1.8 21.1 1045 856 64 51 56 43
3x16rm 1 1.8 20.7 862 559 1.6 1.8 24 1475 1172 0.8x4 1.8 23 1277 974 83 66 75 58
3x25sm 1.2 1.8 21.7 1227 754 1.6 1.8 24.9 1692 1218 0.8x4 1.8 24 1486 1013 110 86 98 76
3x35sm 1.2 1.8 23.6 1601 939 1.6 1.8 26.8 2072 1409 0.8x4 1.8 25.8 1850 1187 130 101 120 93
3x50sm 1.4 1.8 26.5 2175 1228 1.6 1.9 29.9 2668 1722 0.8x4 1.9 28.9 2422 1475 155 120 150 116
3x70sm 1.4 1.9 30 2946 1621 2 2 34.1 3657 2332 0.8x4 2 32.7 3202 1877 190 148 190 148
3x95sm 1.6 2.1 35 4003 2204 2 2.2 39.1 4723 2925 0.8x4 2.1 37.5 4183 2384 225 175 230 179
3x120sm 1.6 2.2 37.7 4920 2647 2 2.3 41.9 5615 3343 0.8x4 2.2 40.3 2035 2763 260 202 270 210
3x150sm 1.8 2.3 41.3 6076 3236 2.5 2.5 46.8 7171 4331 0.8x4 2.3 44.2 6122 3282 295 229 305 237
3x185sm 2 2.4 46 7504 4001 2.5 2.6 51.5 8587 5084 0.8x4 2.5 48.9 7426 3923 330 257 350 272
3x240sm 2.2 2.6 51 9552 5008 2.5 2.8 56.4 10564 6020 0.8x4 2.6 53.8 9290 4736 385 299 410 318
3x300sm 2.4 2.8 56.6 11890 6210 2.5 2.9 61.8 12775 7094 0.8x4 2.8 59.2 11371 5691 425 329 470 364
3x400sm 2.6 3 62.8 15471 7897 3.15 3.2 6802 16178 8604 0.8x4 3 65.6 14629 7055 458 375 503 398
ISO 9001:2008 DESCRIPTION: Three and half core Copper/Aluminum Conductor, PVC Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round
Steel wire armoured/Flat Steel wire armoured and PVC outer sheathed cables
STANDARD: BDS-IEC 60502 (1) VDE-0271 BS- 6346
APPLICATION: Can be used indoors or outdoors, in cable ducts or tray or under ground in power switching stations, in local
distribution systems, Industrial plants, and commercial buildings
No. of cores =3.5C Temperature Range = -15°C to +70°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size of thick NYY / YY / AYY NYRY / YRY / AYRY NYFGY / YFGY / AYFGY
conductor of
Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight armour thick of overall Weight of thick overall Weight 30°C in ground 35°C in air
of outer diameter of cable wire outer diameter of cable armour of outer diameter of cable
30 sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
3.5x25sm 1.2 1.8 23 1234 659 1.6 1.8 26.2 1907 1333 0.8x4 1.8 25.2 1691 1116 110 86 98 76
3.5x35sm 1.2 1.8 25 1554 790 1.6 1.8 28.3 2290 1527 0.8x4 1.8 27.2 2056 1293 130 101 120 93
3.5x50sm 1.4 1.9 28.5 2156 1051 1.6 2 31.8 3003 1903 0.8x4 1.9 30.7 2731 1626 155 120 150 116
3.5x70sm 1.4 2 32.5 2917 1371 2 2.1 36.7 4148 2602 0.8x4 2 34.7 3578 2031 190 148 190 148
3.5x95sm 1.6 2.2 37.4 3928 1813 2 2.3 41.6 5339 3225 0.8x4 2.2 40 4764 2649 225 175 230 179
3.5x120sm 1.6 2.3 40.9 4928 2214 2.5 2.4 46.1 6878 4164 0.8x4 2.3 43.5 5843 3129 260 202 270 210
3.5x150sm 1.8 2.4 44.9 5910 2628 2.5 2.6 50.4 8074 4792 0.8x4 2.4 47.5 6919 3637 295 229 305 237
3.5x185sm 2 2.6 49.6 7070 2967 2.5 2.7 54.8 9418 5316 0.8x4 2.6 52.1 8181 4079 330 257 350 272
3.5x240sm 2.2 2.8 56.3 9388 4086 2.5 2.9 61.5 12048 6746 0.8x4 2.8 59.1 10682 5380 385 299 410 318
3.5x300sm 2.4 3 61.7 11719 5092 2.5 3.1 66.9 14625 7998 0.8x4 3 64.3 13104 6477 425 329 470 364
3.5x400sm 2.6 3.2 68.9 15245 6503 3.13 3.4 75.6 19407 10666 0.8x4 3.2 71.7 16828 8086 458 375 503 398
ISO 9001:2008 DESCRIPTION: Four core Copper/Aluminum Conductor, PVC Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round Steel.
wire armoured/Flat steel wire armoured and PVC outer sheathed cables
STANDARD: BDS- IEC 60502 (1) VDE-0271 BS- 6346
APPLICATION: Can be used indoors or outdoors, in cable ducts or tray or under ground in power switching stations, in local
distribution systems, in Industrial plants, and commercial buildings
No. of cores =4C Temperature Range = -15°C to +70°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick NYY / YY / AYY NYRY / YRY / AYRY NYFGY / YFGY / AYFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight armour thick of overall Weight of thick overall Weight 30°C in ground 35°C in air
of outer diameter of cable wire outer diameter of cable armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
4x1.5rm 0.8 1.8 11.6 198 0.9 1.8 15.5 458 22 17
4x2.5rm 0.8 1.8 12.7 258 1.25 1.8 17.3 629 30 24
4x4rm 1 1.8 15 374 274 1.25 1.8 19.6 814 713 38 31 32 25
4x6rm 1 1.8 16.3 481 330 1.25 1.8 20.9 960 809 48 39 41 34
31 4x10rm 1 1.8 18 667 414 1.6 1.8 23.3 1321 1069 0.8X4 1.8 22.3 1161 909 64 51 56 43
4x16rm 1 1.8 22.5 1058 654 1.6 1.8 25.7 1693 1289 0.8X4 1.8 24.7 1513 1109 83 66 75 58
4x25sm 1.2 1.8 24.4 1363 732 1.6 1.8 27.6 2059 1428 0.8X4 1.8 26.6 1862 1231 110 86 98 76
4x35sm 1.2 1.8 26.6 1780 896 1.6 1.9 30 2557 1673 0.8X4 1.9 29 2342 1459 130 101 120 93
4x50sm 1.4 1.9 30.1 2438 1175 2 2 34.4 3599 2286 0.8X4 2 33 3140 1878 155 120 150 116
4x70sm 1.4 2 34.2 3309 1541 2 2.2 38.6 4593 2826 0.8X4 2.1 37 4110 2343 190 148 190 148
4x95sm 1.6 2.2 39.3 4427 2028 2 2.4 43.7 5905 3506 0.8X4 2.3 42.1 5350 2953 225 175 230 179
4x120sm 1.6 2.3 43.5 5512 2482 2.5 2.5 48.9 7559 4529 0.8X4 2.4 46.3 6537 3507 260 202 270 210
4x150sm 1.8 2.5 48.1 6833 3046 2.5 2.7 53.6 9097 5310 0.8X4 2.6 51 7968 4181 295 229 305 237
4x185sm 2 2.7 53.3 8376 3706 2.5 2.8 58.5 852 6181 0.8X4 2.7 54.9 9606 4935 330 257 350 272
4x240sm 2.2 2.9 59.7 10768 4710 2.5 3 64.9 13550 7490 0.8X4 2.9 62.3 12151 6092 385 299 410 318
4x300sm 2.4 3.1 66 13328 5754 3.15 3.3 72.7 17248 9674 0.8X4 3.1 68.6 14860 7286 425 329 470 364
4x400sm 2.6 3.3 73.7 17488 7389 3.15 3.6 80.6 21908 11810 0.8X4 3.4 76.5 19240 9141 458 375 503 398
ISO 9001:2008 DESCRIPTION: Single core Copper/Aluminum Conductor, XLPE Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round AL.
wire armoured/AL. Double Tape armoured and PVC outer sheathed cables
STANDARD: BDS- IEC 60502 (1) VDE-0272 BS- 5467
APPLICATION: Can be used indoors or outdoors, in cable ducts or Tray or under ground in power switching stations, in local
distribution systems, in Industrial plants, and commercial buildings
No. of cores =1C Temperature Range = -20°C to +90°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED AL. ROUND WIRE ARMOUR AL. DOUBLE TAPE ARMOUR CURRENT RATING
size thick N2XY / 2XY / A2XY N2XRaY / 2XRaY / A2XRaY N2XBaY / 2XBaY / A2XBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight armour thick of overall Weight of thick overall Weight 30°C in ground 35°C in air
of outer diameter of cable wire outer diameter of cable armour of outer diameter of cable
sheath CU AL sheath CU AL Tape sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
1x1.5rm 0.7 1.4 6.1 50 1.25 1.8 10.3 146 36 30
1x2.5rm 0.7 1.4 6.5 63 1.25 1.8 10.8 166 47 39
1x4rm 0.7 1.4 7.3 82 57 1.25 1.8 11.3 191 166 59 47 50 39
1x6rm 0.7 1.4 7.9 105 68 1.25 1.8 11.9 222 185 78 64 69 56
32 1x10rm 0.7 1.4 8.8 147 85 1.25 1.8 12.6 272 210 100 77 94 72
1x16rm 0.7 1.4 9.9 210 111 1.25 1.8 13.6 348 249 130 101 125 97
1x25rm 0.9 1.4 11 309 155 1.25 1.8 15.2 469 314 0.5x20 1.8 14.5 390 235 155 120 160 125
1x35rm 0.9 1.4 12.1 410 194 1.25 1.8 16.3 584 367 0.5x20 1.8 15.6 500 280 185 144 195 150
1x50rm 1 1.4 13.6 557 248 1.25 1.8 17.6 747 438 0.5x20 1.8 17.1 650 343 225 175 245 190
1x70rm 1.1 1.4 15.4 758 325 1.25 1.8 19.4 972 539 0.5x20 1.8 18.9 870 435 270 210 300 233
1x95rm 1.1 1.5 17.1 1012 425 1.25 1.8 21.2 1241 653 0.5x20 1.8 20.6 1175 540 310 240 350 272
1x120rm 1.2 1.5 18.8 1262 520 1.6 1.8 23.7 1565 823 0.5x30 1.8 22.3 1410 670 350 272 405 315
1x150rm 1.4 1.6 21 1568 639 1.6 1.8 25.4 1886 958 0.5x30 1.8 24.5 1630 805 390 302 460 357
1x185rm 1.6 1.6 23 1920 775 1.6 1.8 27.5 2269 1124 0.5x30 1.8 26.5 2025 945 450 350 555 430
1x240rm 1.7 1.7 25.6 2462 978 1.6 1.9 30.2 2848 1363 0.5x30 1.8 29.1 2655 1200 515 400 640 498
1x300rm 1.8 1.8 28.3 3078 1223 1.6 1.9 33 3490 1633 0.5x30 1.9 31.8 3283 1428 585 463 770 537
1x400rm 2 1.9 32 4044 1570 2 2 37.2 4598 2123 0.5x40 2 36.5 4310 1850 680 509 900 626
1x500rm 2.2 2 35.4 5055 1810 2 2.1 41 5509 2505 0.5x40 2.1 39.8 5230 2160 800 592 1030 731
1x630rm 2.4 2.2 39.5 6320 2380 2 2.3 45.2 6809 3100 0.5x40 2.2 44 6560 2730 945 696 1160 837
1x800rm 2.6 2.3 45 8015 2950 2.5 2.4 52 8695 3875 0.5x40 2.3 50 8355 3270 1095 821 1310 942
1x1000rm 2.8 2.4 50 10005 3610 2.5 2.6 57.3 10754 4735 0.5x40 2.4 55.5 10375 4170 1270 952 1480 1064
ISO 9001:2008 DESCRIPTION: Single core Copper/Aluminum Conductor, XLPE Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round Steel
wire armoured/Flat Steel wire armoured and PVC outer sheathed cables
STANDARD: BDS-IEC 60502 (1) VDE-0272 BS- 5467
APPLICATION: Can be used indoors or outdoors, in cable ducts or Tray or under ground in power switching stations, in local
distribution systems, in Industrial plants, and commercial buildings
No. of cores = 2C ! ! Temperature Range = -20°C to +90°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick N2XY / 2XY / A2XY N2XRY / 2XRY / A2XRY N2XFGY / 2XFGY / A2XFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Wt. of Cable armour thick of overall Wt. of Cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL Tape sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
33 2x1.5rm 0.7 1.8 9.8 130 1.25 1.8 13.7 350 34 28
2x2.5rm 0.7 1.8 10.7 166 1.25 1.8 14.6 338 44 36
2x4rm 0.7 1.8 11.8 215 165 1.25 1.8 15.7 397 346 55 42 42 38
2x6rm 0.7 1.8 12.9 276 200 1.25 1.8 17.5 554 478 74 53 53 51
2x10rm 0.7 1.8 14.3 379 253 1.25 1.8 18.9 676 550 97 70 70 65
2x16rm 0.7 1.8 16.3 539 337 1.25 1.8 20.9 1018 816 0.8x4 1.8 20.6 986 784 125 89 89 87
2x25Rm 0.9 1.8 19.6 802 487 1.6 1.8 24.9 1513 1197 0.8x4 1.8 23.9 1840 1024 150 110 110 109
2x35Rm 0.9 1.8 21.8 1056 614 1.6 1.8 27.1 1846 1404 0.8x4 1.8 26 1655 1213 180 126 126 122
2x50Rm 1 1.9 24.4 1420 789 1.6 1.9 29.9 2320 1689 0.8x4 1.9 28.9 2106 1475 212 154 154 156
2x70Rm 1.1 2 28.2 1947 1063 2 2.1 34.7 3225 2342 0.8x4 2 32.7 2738 1854 256 185 185 189
2x95Rm 1.1 2.1 32 2583 1384 2 2.2 38.5 4027 2828 0.8x4 2.2 37.1 3564 2365 293 214 214 220
2x120Rm 1.2 2.2 36 3259 1745 2 2.3 42.3 4848 3333 0.8x4 2.3 40.9 4334 2819 332 242 242 252
2x150Rm 1.4 2.4 40 4030 2137 2.5 2.5 47.2 6195 4301 0.8x4 2.4 44.6 5214 3321 366 271 271 284
2x185Rm 1.6 2.6 44.1 4970 2635 2.5 2.6 51.7 7372 5036 0.8x4 2.6 49.3 6310 3975 427 315 315 330
ISO 9001:2008 DESCRIPTION: Three core Copper/Aluminum Conductor, XLPE Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round Steel
wire armoured/Flat Steel wire armoured and PVC outer sheathed cables
STANDARD: BDS-IEC 60502 (1) VDE-0272 BS- 5467
APPLICATION: Can be used indoors or outdoors, in cable ducts or Tray or under ground in power switching stations, in local
distribution systems, in Industrial plants, and commercial buildings
No. of cores =3C Temperature Range = -20°C to +90°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick N2XY / 2XY / A2XY N2XRY / 2XRY / A2XRY N2XFGY / 2XFGY / A2XFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Wt. of Cable armour thick of overall Wt. of Cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
3x1.5rm 0.7 1.8 10.3 161 1.25 1.8 14.2 379 30 23
3x2.5rm 0.7 1.8 11.3 210 1.25 1.8 15.2 446 38 32
34 3x4rm 0.7 1.8 12.4 278 202 1.25 1.8 17 621 545 48 34 41 31
3x6rm 0.7 1.8 13.6 363 249 1.25 1.8 18.2 734 621 64 40 56 40
3x10rm 0.7 1.8 15.1 511 321 1.25 1.8 19.7 918 728 83 55 75 53
3x16rm 0.7 1.8 19.4 776 473 1.6 1.8 22.6 1314 1011 0.8x4 1.8 21.6 1159 856 110 73 98 70
3x25sm 0.9 1.8 20.3 992 518 1.6 1.8 23.5 1558 1085 0.8x4 1.8 22.5 1396 923 130 94 120 96
3x35sm 0.9 1.8 22.2 1304 641 1.6 1.8 25.4 1931 1269 0.8x4 1.8 24.5 1753 1090 155 114 150 117
3x50sm 1 1.8 24.6 1774 827 1.6 1.9 27.9 2476 1530 0.8x4 1.8 26.9 2278 1331 190 133 190 142
3x70sm 1.1 1.9 28.5 2409 1083 1.6 2 32 3245 1919 0.8x4 1.9 30.8 2998 1673 225 164 230 179
3x95sm 1.1 2 32.4 3230 1430 2 2.1 36.7 4425 2626 0.8x4 2 34.6 3904 2106 260 196 270 221
3x120sm 1.2 2.1 35.7 4005 1733 2 2.2 39.9 5323 3051 0.8x4 2.1 38.3 4821 2549 295 223 305 257
3x150sm 1.4 2.2 39.4 4949 2109 2 2.4 43.8 6430 3590 0.8x4 2.3 42.2 5875 3034 330 249 350 292
3x185sm 1.6 2.4 44.2 6120 2617 2.5 2.5 49.5 8175 4672 0.8x4 2.4 46.9 7139 3636 385 282 410 337
3x240sm 1.7 2.5 48.5 7791 3247 2.5 2.7 54 10074 5529 0.8x4 2.6 51.3 5936 4392 425 327 470 400
3x300sm 1.8 2.7 53.6 9700 4020 2.5 2.9 59.1 12227 6546 0.8x4 2.7 56.3 10941 5261 478 368 564 455
3x400sm 2 2.9 59.9 12712 5138 2.5 3.1 65.3 15533 7959 0.8x4 2.9 62.5 14099 6525 566 436 626 515
ISO 9001:2008 DESCRIPTION: Three and Half core Copper/Aluminum Conductor, XLPE Insulated, Cores laid up, PVC inner sheathed, Unarmoured/
Round Steel wire armoured/Flat Steel wire armoured and PVC outer sheathed cables
STANDARD: BDS-IEC 60502 (1) VDE-0272 BS- 5467
APPLICATION: Can be used indoors or outdoors, in cable ducts or Tray or under ground in power switching stations, in local
distribution systems, in Industrial plants, and commercial buildings
No. of cores =3.5C Temperature Range = -20°C to +90°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick N2XY / 2XY / A2XY N2XRY / 2XRY / A2XRY N2XFGY / 2XFGY / A2XFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
35 3.5x25sm 0.9 1.8 21.6 1161 587 1.6 1.8 24.8 1768 1193 0.8x4 1.8 23.8 1595 1021 130 94 120 96
3.5x35sm 0.9 1.8 23.6 1483 720 1.6 1.8 26.8 2144 1380 0.8x4 1.8 25.8 1954 1190 155 114 150 117
3.5x50sm 1 1.8 26.3 2045 941 1.6 0.9 29.7 2805 1700 0.8x4 1.8 28.5 2577 1472 190 133 190 142
3.5x70sm 1.1 1.9 30.8 2799 1253 2 2.1 35.2 3893 2347 0.8x4 2 33.2 3353 1898 225 164 230 179
3.5x95sm 1.1 2.1 34.8 3760 1646 2 2.2 39 5028 2913 0.8x4 2.1 37.4 4539 2424 260 196 270 221
3.5x120sm 1.2 2.2 38.8 4725 2010 2 2.4 43.2 6230 3512 0.8x4 2.2 41.4 5613 2899 295 223 305 257
3.5x150sm 1.4 2.3 42.8 5707 2425 2.5 2.5 48.2 7777 4495 0.8x4 2.5 45.7 6693 3411 330 249 350 292
3.5x185sm 1.6 2.5 47.4 6918 2815 2.5 2.6 52.6 9172 5070 0.8x4 2.5 50 7983 3881 385 282 410 337
3.5x240sm 1.7 2.7 53.7 9089 3787 2.5 2.8 58.9 11632 6330 0.8x4 2.7 56.3 10296 4994 425 327 470 400
3.5x300sm 1.8 2.8 58.4 11283 4656 2.5 3 639 14080 7453 0.8x4 2.9 61.3 12630 6003 478 368 564 455
3.5x400sm 2 3.1 65.5 14645 5904 2.5 3.2 71 17857 9116 0.8x4 3.1 68.5 16238 7497 566 436 626 515
ISO 9001:2008 DESCRIPTION: Four core Copper/Aluminum Conductor, XLPE Insulated, Cores laid up, PVC inner sheathed, Unarmoured/Round Steel
wire armoured/Flat Steel wire armoured and PVC outer sheathed cables
STANDARD: BDS-IEC 60502 (1) VDE-0272 BS- 5467
APPLICATION: Can be used indoors or outdoors, in cable ducts or Tray or under ground in power switching stations, in local
distribution systems, in Industrial plants, and commercial buildings
No. of cores =4C Temperature Range = -20°C to +90°C Voltage Grade = 0.6/1( 1.2) KV
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick N2XY / 2XY / A2XY N2XRY / 2XRY / A2XRY N2XFGY / 2XFGY / A2XFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
4x1.5rm 0.7 1.8 11.1 173 1.25 1.8 15.7 255 30 23
4x2.5rm 0.7 1.8 12.1 229 1.25 1.8 16.7 347 38 32
36 4x4rm 0.7 1.8 13.5 308 207 1.25 1.8 18.1 433 332 48 34 41 31
4x6rm 0.7 1.8 14.8 407 255 1.25 1.8 19.4 538 387 64 40 56 40
4x10rm 0.7 1.8 16.5 584 331 1.25 1.8 21.1 723 471 83 55 75 53
4x16rm 0.7 1.8 21 953 549 1.6 1.8 24.2 1573 1169 0.8X4 1.8 23.2 1384 981 110 73 98 70
4x25sm 0.9 1.8 22.3 1274 643 1.6 1.8 25.5 1935 1304 0.8X4 1.8 24.5 1731 1100 130 94 120 96
4x35sm 0.9 1.8 24.7 1684 801 1.6 1.8 27.9 2419 1536 0.8X4 1.8 26.9 2198 1314 155 114 150 117
4x50sm 1 1.8 27.7 2302 1040 1.6 1.9 31.1 3149 1887 0.8X4 1.9 30.1 2901 1639 190 133 190 142
4x70sm 1.1 1.9 31.1 3142 1374 2 2 35 4295 2528 0.8X4 2 33.6 3889 2122 225 164 230 179
4x95sm 1.1 2 36 4199 1801 2 2.2 40.5 5609 3211 0.8X4 2.2 39.1 5087 2688 260 196 270 221
4x120sm 1.2 2.2 40.4 5275 2245 2 2.4 44.9 6848 3819 0.8X4 2.3 43.3 6248 3218 295 223 305 257
4x150sm 1.4 2.4 45.1 6550 2763 2.5 2.6 50.5 8748 4961 0.8X4 2.5 47.9 7633 3846 330 249 350 292
4x185sm 1.6 2.5 49.5 8005 3334 2.5 2.7 55 10417 5747 0.8X4 2.6 52.4 9205 4535 385 282 410 337
4x240sm 1.7 2.7 56 10321 4262 2.5 2.9 61.4 13042 6983 0.8X4 2.9 59 11701 5642 425 327 470 400
4x300sm 1.8 2.8 60.9 12743 5169 2.5 3.1 66.6 15736 8132 0.8X4 3 64 14260 6686 478 368 564 455
4x400sm 2 3.1 68.6 16767 6669 3.15 3.4 75.6 21011 10913 0.8X4 3.2 71.6 18119 8021 566 436 626 515
ISO 9001:2008
ISO 9001:2008
Manufacturing Data:
Cross Concentric Nominal Nominal Approx. Approx. Current Current
sectional copper thickness thickness cable weight rating at rating
area conductor of of dia. of 30°C in at 35°C
stranded insulation sheath cable Ground in Air
or Braided
Cu AL Cu AL Cu AL
mm² No./mm mm mm mm Kg/km Kg/km Amps Amps Amps Amps
3X2.5rm/1.5 80/0.15 0.7 1.8 13.7 303 - 38 - 32 -
3X4rm/2.5 76/0.20 0.7 1.8 15.1 388 280 48 34 41 31
3X6rm/4 80/0.25 0.7 1.8 16.6 507 324 64 40 56 40
3X10rm/6 80/0.30 0.7 1.8 18.0 687 435 83 55 75 53
3X16rm/10 78/0.40 0.7 1.8 20.2 1033 620 110 73 98 70
3X25sm/16 80/0.50 0.9 1.8 23.75 1240 790 130 94 120 96
3X35sm/16 80/0.50 0.9 1.8 24.1 1520 910 155 114 150 117
3C50sm/25 50/0.80 1.0 1.8 28.7 2162 1203 190 133 190 142
3X70sm/35 70/0.80 1.1 1.8 32.4 2820 1550 225 164 230 179
3X95sm/50 60/1.02 1.1 1.9 37.7 3831 1955 260 196 270 221
3X120sm/70 70/1.12 1.2 2.0 40.0 4810 2170 295 223 305 257
3X150sm/70 70/1.12 1.4 2.2 43.7 5840 2880 330 249 350 292
3X185sm/95 67/1.35 1.6 2.4 48.0 7300 3425 385 282 410 337
3X240sm/120 67/1.53 1.7 2.6 53.8 9260 4232 425 327 470 400
3X300sm/150 80/1.56 1.8 2.8 59.3 11540 5356 478 368 564 455
3X400sm/185 74/1.78 2.0 3.0 63.2 15190 6869 520 425 565 460
ISO 9001:2008
APPLICATION: Used as Aerial down leads in local and fringe reception areas at both
Very High Frequency and Ultra High Frequency applications.
CO NSTRUCTIO N: Plain annealed Copper conductor as per IEC 228, Polyethylene
insulated, AMT shielded, Plain copper wire Braided and PVC sheathed in Black colour as
per BS 6746.
TECHNICAL DATA: AS PER BELDEN SPECIFICATION
MANUFACTURING DATA:
Cable Wire Strand Dia. Of AMT & Screen Sheath Nom. Approx.
Code gauge dia. core with Braid thick O.D. weight
dielectric resistance
MANUFACTURING DATA:
Strand dia. 0.5 mm !Strand dia. 0.6 mm
Pair Inns. Thick
Sh. thick App. O.D. App. Wt. Sh. Thick App. O.D. App. Wt.
No. mm mm mm Kg/km mm mm Kg/km
ISO 9001:2008
UL - 1424
APPLICATION: Can be used as a fixed wiring within building and also as a power limited
circuit cable.
CONSTRUCTION: Solid Annealed conductor (as per ASTM B3), Extruded solid FR PVC
Color coded cores are assembled and shielded with AMT and drain wire. Red color PVC
jacket is provided.
TECHNICAL DATA: Voltage Grade: 300/500V; Temperature Range: -20°C to +90°C
B. R. = 12XCable Ø
Colour code:
No. of Conductors Colour No. of Conductors Colour
1 Black 4 Blue
2 Red 5 Brown
3 Yellow 6 Orange
UNSHIELDED CABLES:
Sl. No. Size Cores Strand x dia. Insulation Sheath Approx. Approx.
AWG thickness thickness O. D. weight
No. mm mm mm mm Kg/km
SHIELDED CABLES:
Sl. No. Size Cores Strand x dia. Insulation Sheath Approx. Approx.
AWG thickness thickness O. D. weight
No. mm mm mm mm Kg/km
APPLICATION: These cables are especially suitable for control purposes in machine tool
manufacturing, production lines, industrial plants, air conditioning installations and steel plants.
CONSTRUCTION: Plain copper bunched conductor (class 5 of IEC-228), PVC (VDE 0207)
insulated Black cores with white numbers and one green/yellow core. Cores twisted in
layers, Black coloured sheath (IEC 332-1) is provided for outer coating.
TECHNICAL DATA: Working Voltage: 300/500V; Temperature range: -20°C to +80°C
Insulation Resistance = 20MOhm - km; Test voltage = 2000V.for 5 Minutes; B. R. = 12 X Cable Ø
Cable size = 0.5 mm²(16/0.2) 0.75 mm²(24/0.2)
Cores Ins. Thick Sh. Thick App. O.D. APP. Ins. Thick Sh. Thick App. O.D. APP.
No. mm mm mm Wt. mm mm mm Wt.
2 0.6 0.8 6.1 45 0.6 0.8 6.6 70
3 0.6 0.8 6.5 50 0.6 0.8 7.8 90
4 0.6 0.8 7.0 60 0.6 0.9 8.8 115
5 0.6 0.9 7.7 75 0.6 1.0 9.4 135
7 0.6 1.0 8.7 100 0.6 1.1 10.2 160
10 0.6 1.2 11.2 145 0.6 1.2 12.9 230
12 0.6 1.2 11.7 160 0.6 1.2 13.5 275
14 0.6 1.2 12.1 200 0.6 1.3 14.1 305
19 0.6 1.3 13.3 255 0.6 1.4 15.5 380
24 0.6 1.5 16.1 330 0.6 1.5 19.1 520
30 0.6 1.6 17.0 385 0.6 1.6 20.1 605
37 0.6 1.7 19.0 480 0.6 1.7 21.5 705
48 0.6 1.8 21.4 600 0.6 1.8 24.9 910
ISO 9001:2008 APPLICATION: These cables are especially suitable for control purposes in machine tool
manufacturing, conveyor and assembly lines requires electrostatic shielding, subject to
medium mechanical stresses.
CONSTRUCTION: Plain copper bunched conductor (class 5 of IEC-228), PVC (VDE 0207)
insulated Black cores with white numbers and one green/yellow core. Cores twisted in
layers, PVC inner sheathed and Braided with plain copper wires. Grey coloured sheath
(IEC 332-1) is provided for outer coating.
TECHNICAL DATA: Working Voltage: 300/500V; Temperature range: -20°C to +80°C Insulation
Resistance = 20MOhm - km; Test voltage = 2000V.for 5 Minutes; B. R. = 12 X Cable Ø
Cable size = 0.5 mm²(16/0.2) 0.75 mm²(24/0.2)
Cores Ins. Thick Inner sh. Sh. Thick App. O.D. APP.Wt. Ins. Thick Inner sh. Sh. Thick App.O.D. APP. Wt
No. mm mm mm mm Kg/km mm mm mm mm Kg/km
2 0.6 0.7 0.9 8.6 95 0.6 0.7 0.9 9.0 110
3 0.6 0.7 0.9 9.1 110 0.6 0.7 0.9 9.6 130
4 0.6 0.7 0.9 9.9 130 0.6 0.7 1.0 10.7 160
5 0.6 0.7 1.0 10.9 160 0.6 0.7 1.1 11.4 180
7 0.6 0.7 1.1 11.6 175 0.6 0.7 1.2 12.1 200
10 0.6 0.7 1.1 14.1 255 0.6 0.7 1.2 14.7 295
12 0.6 0.8 1.3 14.5 275 0.6 0.8 1.3 15.2 325
14 0.6 0.8 1.3 15.0 305 0.6 0.8 1.3 16.7 390
19 0.6 0.8 1.3 17.3 400 0.6 0.8 1.5 18.6 500
24 0.6 0.8 1.6 19.8 510 0.6 0.8 1.6 21.1 600
30 0.6 0.8 1.6 20.8 590 0.6 0.9 1.7 22.5 710
37 0.6 0.9 1.7 22.4 700 0.6 1.0 1.8 24.4 865
48 0.6 0.9 1.9 25.5 900 0.6 1.0 2.1 27.5 1085
ISO 9001:2008
Cross Linked Polyethylene Cable i.e. XLPE cable was developed in late 1970 to overcome the
susceptibility of PILC Cables to ingress of moisture. There after XLPE has replaced all other
materials in almost all voltage applications particularly from 3.3KV to 500KV category.
The excellent thermal properties of XLPE Cable permit maximum continuous conductor
operating temperature of 90°C and short circuit temperature of 250°C. Moreover, it has low
dielectric loss, which does not vary much over the entire operating range. These
characteristics, along with the low dielectric constant, make XLPE compound, particularly
suitable for high voltage cable applications.
APPLICATIONS:
Extensively used for power Transmission where overhead lines to be discouraged, in Power
generating plants, in Industrial plants, suitable to use where power /load/temperature
fluctuations are more and in most difficult cable route conditions such as city distribution net
work etc.
CONDUCTOR
Normally, Round Compact Smooth Conductors are used for High voltage cables to ensure
minimum stress development on the surface of the conductor, are made of Copper or
Aluminum of sizes between 25 to 630mm².
TRIPLE EXTRUSION
Extrusion is done in a closed triple crosshead. Inner semiconducting compound, XLPE
insulating compound and outer semiconducting compound are fed into respective extruders
in a contamination-free closed circuit system through preheater and dehumidifier. The
quantum and the size of microvoid formation is to be restricted much below specified level
by careful process control, and choice of quality compounds.
The Line is operated with X-RAY 8000 (SIKORA) Scanner; display the on-line product
parameters, offers following functions: Measurement of
! P Outer diameter and ovality
! P Wall thickness of outer semiconductor, insulation, and inner semiconductor
! P Eccentricity of outer semiconductor, insulation, inner semiconductor
! P Core diameter and ovality
! P Total wall thickness
! P Graphic and numerical display of measuring values about wall thickness and diameter
! P Measuring value control
! P Comparison of measuring values wall thickness and diameter to nominal values and !
! ! tolerance limits
! P Statistical information and graphical display of selectable measuring values
! P Graphical display of scan intensity level
! P Serial interface to RS 422
CURING
Curing under oxygen-free nitrogen gas pressure is carried out in Catenary Continuous
Vulcanization (CCV) line as per the recommended practice. Longer cooling length under
pressure restrict the size of voids to be below micron level while the quantum are further
minimized to ensure minimum Partial discharge level, thus guaranteeing longer performance
and life of the product.
ISO 9001:2008
METALLIC SCREENING
Screening with copper tape along with suitable overlap ensures a uniform radial stress
distribution around the axis of the cable core, thus ensuring stable performance. As per the
customer requirements, suitable screen structure can be designed.
ASSEMBLING
Assembly of cores in a precisely controlled laying up machine with an anti torsion device, so
as to avoid any stress formation on the cores and applied screen. Interstices between cores
are filled with suitable non-hygroscopic fillers.
INNER SHEATH
Extruded PVC inner sheath is applied over the assembly of the cores. This coating should be
free from any pin holes and is impervious to moisture
ARMOURING
Galvanized steel round wire, flat wire or tapes are used to armour the cable with suitable layer
and so ensuring required armour resistance value for diverting fault current as per specific
requirement. Single core armoured cables are provided with non-magnetic armour consisting
of hard drawn round wire or flat tape of aluminum will be provided.
OUTER SHEATH
A tough outer sheath of Heat Resisting PVC compound (Type ST2) or Polyethylene is extruded
over the armouring in case of armoured cables or over inner sheath in case of unarmoured
cables or over non-magnetic metallic part of insulation screening in case of unarmoured
single core cables. It protects the cable from the influence of surrounding affluent like Acids,
Alkalis, Salts, emulsions and Organic substances. This is always in RED colour for easy
identification.
CORE IDENTIFICATION
In case of multi core cables, core identification is done by providing the coloured (Red,
Yellow, Blue) tapes below metallic core screen
TEST VOLTAGES
The following voltage is applied between conductor and screen / armour
ISO 9001:2008 DESCRIPTION: Single core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed, Un-
armoured/ AL. wire armoured / AL Double Tape armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND WIRE(AL) ARMOURED DOUBLE TAPE(AL)ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRaY/A2XSEYRaY 2XSEYBaY/A2XSEYBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
57 10 2.5 1.8 15.2 324 261 1.6 1.8 20.5 583 520 0.5X30 1.8 21.0 626 564 56 39 65 42
16 2.5 1.8 16.1 400 299 1.6 1.8 21.5 672 572 0.5X30 1.8 21.9 717 617 90 62 104 68
25 2.5 1.8 17.4 518 364 1.6 1.8 22.7 823 668 0.5X30 1.8 23.2 875 720 140 97 163 106
35 2.5 1.8 18.5 635 418 1.6 1.8 23.8 957 740 0.5X30 1.8 24.3 1011 794 166 118 198 130
50 2.5 1.8 19.6 796 418 1.6 1.8 24.9 1135 825 0.5X30 1.8 25.4 1191 882 196 136 238 156
70 2.5 1.8 21.2 1013 580 2 1.8 26.5 1378 945 0.5X30 1.8 27 1438 1005 239 166 296 196
95 2.5 1.8 23 1281 693 2 1.8 28.3 1675 1087 0.5X30 1.9 29 1753 1165 285 197 361 239
120 2.5 1.8 24.6 1542 800 2 1.9 30.1 1976 1234 0.5X30 1.9 30.5 2043 1300 323 224 417 277
150 2.5 1.8 26 1843 915 2 2 32 2351 1423 0.5X30 2 32 2385 1457 361 252 473 318
185 2.5 1.8 27.6 2198 1053 2 2.1 34.8 2838 1693 0.5X30 2 33.8 2772 1627 406 284 543 368
240 2.6 1.9 30.7 2798 1313 2.5 2.2 37.8 3503 2018 0.5X40 2.1 36.8 3430 1944 469 329 641 440
300 2.8 2 33.7 3440 1583 2.5 2.3 40.9 4209 2352 0.5X40 2.3 40.3 4170 2314 526 372 735 509
400 3 2.1 37.1 4456 1981 2.5 2.4 45.7 5485 3009 0.5X40 2.4 43.7 5255 2779 590 427 845 602
500 3.2 2.2 40.5 5478 2384 2.5 2.6 49 6591 3497 0.5X40 2.5 47 6342 3248 669 485 958 699
630 3.2 2.3 44.2 6769 2871 2.5 2.7 52.8 7978 4079 0.5X40 2.6 51 7734 3836 760 551 1089 790
ISO 9001:2008 DESCRIPTION: Three core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed, Un-
armoured/ Steel wire armoured / steel strip armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRGY/A2XSEYRGY 2XSEYFGY/A2XSEYFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
58 3X10 2.5 1.9 31.0 1243 1053 2 2.1 35.3 2345 2155 0.8X4 2.0 33.7 1910 1721 52 38 56 40
3X16 2.5 2.0 33.5 1558 1255 2 2.2 38.0 2758 2455 0.8X4 2.1 36.2 2287 1984 83 60 92 64
3X25 2.5 2.1 36.4 2030 1556 2 2.3 40.9 3402 2928 0.8x4 2.2 39.3 2886 2413 129 94 143 100
3X35 2.5 2.2 39 2470 1806 2 2.4 43.4 3934 3276 0.8x4 2.3 41.8 3387 2725 154 111 172 121
3X50 2.5 2.3 41.6 3052 2105 2.5 2.5 47 5010 4063 0.8x4 2.4 44.4 4032 3085 181 130 205 145
3X70 2.5 2.4 45.7 3898 2572 2.5 2.6 51.1 6053 4727 0.8x4 2.5 48.5 4977 3652 220 160 253 181
3X95 2.5 2.6 50 4909 3110 2.5 2.7 55.2 7236 5437 0.8x4 2.6 52.6 6063 4265 263 191 307 221
3X120 2.5 2.7 53.6 5872 3599 2.5 2.8 58.8 8367 6095 0.8x4 2.8 56.4 7140 4868 298 217 352 254
3X150 2.5 2.8 57.1 7005 4165 2.5 3 62.5 9700 6860 0.8x4 2.9 59.9 8359 5518 332 243 397 290
3X185 2.5 3 61.2 8326 4823 2.5 3.1 66.4 11178 7674 0.8x4 3 63.8 9743 6240 374 274 453 330
3X240 2.6 3.1 67.5 10466 5922 3.15 3.3 74.2 14488 9944 0.8x4 3.2 70.9 12271 7727 431 317 529 390
3X300 2.8 3.4 74.7 12908 7227 3.15 3.5 81.4 17349 11669 0.8x4 3.5 78.1 14903 9222 482 358 599 450
3X400 3 3.6 82 16483 8909 3.15 3.6 88.3 21276 13702 0.8x4 3.7 85.5 18678 11105 541 408 683 525
ISO 9001:2008 DESCRIPTION: Single core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/ AL. wire armoured / AL. Double Tape armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND WIRE(AL) ARMOURED DOUBLE TAPE(AL) ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRaY/A2XSEYRaY 2XSEYBaY/A2XSEYBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
16 3.4 1.8 18.0 457 357 1.6 1.8 23.3 688 588 0.5X30 1.8 23.7 826 726 118 84 122 90
25 3.4 1.8 19.3 613 458 1.6 1.8 24.6 947 793 0.5X30 1.8 25 1022 867 141 99 150 115
35 3.4 1.8 20.4 702 485 1.6 1.8 25.7 1054 837 0.5X30 1.8 26.1 1131 915 170 115 178 140
50 3.4 1.8 21.5 866 556 1.6 1.8 26.8 1235 926 0.5X30 1.8 27.2 1316 1006 205 140 215 170
59 70 3.4 1.8 23.1 1088 655 1.6 1.9 28.6 1498 1065 0.5X30 1.8 28.8 1568 1135 254 170 268 210
95 3.4 1.8 24.9 1361 773 1.6 1.9 30.4 1801 1213 0.5X30 1.9 30.8 1891 1303 301 200 330 255
120 3.4 1.8 26.5 1627 884 1.6 2 32.2 2109 1367 0.5X30 2 32.6 2204 1416 343 230 386 295
150 3.4 1.8 27.8 1932 1004 2 2.1 34.6 2538 1610 0.5X30 2 33.9 2536 1608 386 255 441 335
185 3.4 1.9 29.7 2307 1162 2 2.1 36.7 2972 1827 0.5X30 2.1 35.8 2948 1803 435 290 510 385
240 3.4 2 32.6 2906 1421 2 2.2 39.5 3630 2145 0.5X40 2.1 38.5 3582 2097 503 330 602 455
300 3.4 2.1 35.2 3532 1676 2 2.3 42.1 4309 2453 0.5X40 2.2 41.1 4258 2402 568 375 688 520
400 3.4 2.2 38.2 4530 2055 2.5 2.5 46.3 5534 3059 0.5X400.5X40 2.3 44.3 5337 2862 650 425 800 610
500 3.4 2.3 41.1 5528 2434 2.5 2.5 49.5 6631 3538 0.5X40 2.4 47.2 6392 3298 719 485 920 720
630 3.4 2.4 44.8 6824 2926 2.5 2.7 53.4 8048 4149 0.5X40 2.6 51.4 7815 3916 820 540 1060 830
ISO 9001:2008 DESCRIPTION: Three core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/ Steel wire armoured / steel strip armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND STEELWIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick 2XSEYY/A2XSEYY 2XSEYRGY/A2XSEYRGY 2XSEYFGY/A2XSEYFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight armour thick of overall Weight of thick overall Weight 30°C in ground 35°C in air
of outer diameter of cable wire outer diameter of cable armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
60 3X16 3.4 2.2 38.0 1874 1570 2.5 2.3 43.1 3547 3244 0.8x4 2.2 40.5 2689 2386 112 80 116 86
3X25 3.4 2.3 40.9 2381 1907 2.5 2.4 46.1 4281 3808 0.8x4 2.3 43.5 3321 2848 134 95 141 105
3X35 3.4 2.4 43.9 2886 2223 2.5 2.5 49.1 4927 4265 0.8x4 2.4 46.5 3897 3234 169 110 175 125
3X50 3.4 2.5 46.5 3493 2546 2.5 2.6 51.7 5655 4708 0.8x4 2.5 49.1 4565 3618 202 130 210 150
3X70 3.4 2.6 50.2 4328 3002 2.5 2.7 55.4 6664 5339 0.8x4 2.6 52.8 5487 4161 249 160 260 190
3X95 3.4 2.7 54.7 5402 3603 2.5 2.9 60.1 7986 6187 0.8x4 2.8 57.5 6700 4901 300 190 320 230
3X120 3.4 2.8 58.3 6396 4124 2.5 3 63.7 9151 6878 0.8x4 2.9 61 7780 5508 335 220 363 260
3X150 3.4 2.9 61.4 7500 4660 2.5 3.1 66.8 10404 7564 0.8x4 3 64.2 8960 6120 381 245 418 285
3X185 3.4 3.1 65.5 8855 5362 2.5 3.2 70.7 11911 8408 0.8x4 3.1 68 10375 6872 421 273 483 335
3X240 3.4 3.3 72 11092 6547 3.15 3.5 78.7 15375 10830 0.8x4 3.3 74.6 12766 8221 488 315 557 395
3X300 3.4 3.4 77.3 13302 7622 3.15 3.7 84.3 17958 12278 0.8x4 3.5 80.8 15374 9694 525 357 586 450
3X400 3.4 3.7 84 16812 9238 3.15 3.9 90.8 21815 14241 0.8x4 3.7 87.3 19015 11441 600 400 710 520
ISO 9001:2008 DESCRIPTION: Single core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/ AL. wire armoured /AL. Double Tape armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND WIRE(AL) ARMOURED DOUBLE TAPE(AL)ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRaY/A2XSEYRaY 2XSEYBaY/A2XSEYBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
25 4.5 1.8 21.6 668 514 1.6 1.8 26.9 1040 885 0.5X30 1.8 27.3 1100.945 867 140 99 163 115
35 4.5 1.8 22.7 792 575 1.6 1.8 28 1180 964 0.5X30 1.8 28.7 1258 1041 166 115 198 140
61 50 4.5 1.8 23.8 959 650 1.6 1.9 29.3 1381 1072 0.5X30 1.9 29.7 1446 1136 196 140 238 170
70 4.5 1.8 25.4 1187 754 1.6 1.9 31 1636 1203 0.5X30 2 31.2 1720 1287 239 170 296 210
95 4.5 1.8 27.2 1466 878 2 2 33.8 2043 1456 0.5X30 2 33.4 2033 1445 285 200 361 255
120 4.5 1.9 29 1753 1010 2 2.1 35.5 2364 1621 0.5X30 2.1 35.1 2352 1610 323 230 417 295
150 4.5 1.9 30.3 2064 1135 2 2.1 37.3 2741 1813 0.5X30 2.1 36.5 2688 1760 361 255 473 335
185 4.5 2 32.3 2447 1302 2 2.2 39.2 3164 2019 0.5X30 2.2 38.4 3107 1962 406 290 543 385
240 4.5 2.1 35 3058 1573 2 2.3 42 3834 2349 0.5X40 2.3 41.2 3772 2287 469 330 641 455
300 4.5 2.2 37.7 3696 1839 2.5 2.4 45.6 4664 2807 0.5X40 2.4 44 4481 2625 526 375 735 520
400 4.5 2.3 40.7 4706 2231 2.5 2.5 49 5799 3324 0.5X40 2.5 47 5549 3074 590 425 845 610
500 4.5 2.4 43.6 5716 2622 2.5 2.6 52 6882 3788 0.5X40 2.6 50 6616 3522 669 485 958 720
630 4.5 2.5 47.3 7028 3129 2.5 2.8 55.9 8315 4417 0.5X40 2.8 54 8055 4157 750 540 1089 830
DESCRIPTION: Three core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/ Steel wire armoured / steel strip armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRGY/A2XSEYRGY 2XSEYFGY/A2XSEYFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
62 3X25 4.5 2.4 46.6 2873 2400 2.5 2.6 52 5071 4598 0.5X30 2.5 49.4 3975 3502 129 95 143 105
3X35 4.5 2.5 49.1 3362 2699 2.5 2.7 54.6 5682 5020 0.5X30 2.6 52 4526 3863 154 110 172 125
3X50 4.5 2.6 52 3994 3048 2.5 2.8 57.1 6436 5490 0.5X30 2.7 54.5 5220 4273 181 130 205 150
3X70 4.5 2.7 56 4920 3594 2.5 2.9 61.2 7559 6233 0.5X30 2.8 58.6 6245 4919 220 160 253 190
3X95 4.5 2.8 60 5983 4184 2.5 3.1 65.5 8853 7055 0.5X30 3 62.9 7441 5642 263 190 307 230
3X120 4.5 2.9 63.4 7011 4738 2.5 3.2 69.1 10054 7782 0.5X30 3.1 66.5 8557 6285 298 220 352 260
3X150 4.5 3.1 66.8 8179 5339 2.5 3.3 72.2 11338 8498 0.5X30 3.2 69.6 9768 6928 332 245 397 285
3X185 4.5 3.3 71.3 9646 6144 3.15 3.5 78 13887 10385 0.5X30 3.3 73.9 11304 7801 374 273 453 335
3X240 4.5 3.4 77.2 11840 7295 3.15 3.7 84.1 16484 11940 0.5X40 3.6 80.8 13949 9404 431 315 529 395
3X300 4.5 3.6 82.8 14144 8464 3.15 3.9 89.7 19124 13444 0.5X40 3.7 86.2 16362 10681 482 357 599 450
3X400 4.5 3.8 89.2 17676 10102 3.15 4.1 96.2 23046 15472 0.5X40 3.9 92.7 20068 12494 541 400 683 520
ISO 9001:2008 DESCRIPTION: Single core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/AL. wire armoured /AL. Double Tape armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND WIRE(AL) ARMOURED DOUBLE TAPE(AL)ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRaY/A2XSEYRaY 2XSEYBaY/A2XSEYBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
63 35 5.5 1.8 24.8 880 663 1.6 1.9 30.3 1319 1102 0.5X30 1.9 30.8 1385 1168 166 118 198 146
50 5.5 1.8 25.9 1051 742 1.6 2 31.7 1525 1215 0.5X30 1.9 31.8 1577 1267 196 140 238 174
70 5.5 1.8 27.5 1284 851 2 2.1 34.3 1885 1452 0.5X30 2 33.7 1857 1424 239 169 296 216
95 5.5 1.9 29.5 1585 997 2 2.1 36.5 2246 1658 0.5X30 2.1 35.7 2194 1607 285 202 361 264
120 5.5 1.9 31.1 1862 1119 2 2.2 38.2 2575 1833 0.5X30 2.1 37.2 2501 1759 323 228 417 303
150 5.5 2 32.7 2194 1266 2 2.3 39.8 2940 2012 0.5X30 2.2 38.3 2862 1933 361 254 473 342
185 5.5 2.1 34.6 2585 1440 2 2.3 41.5 3349 2204 0.5X30 2.2 40.5 3267 2122 406 286 543 392
240 5.5 2.2 37.4 3208 1723 2.5 2.4 45.3 4169 2683 0.5X40 2.3 43.5 3965 2480 469 328 641 462
300 5.5 2.3 40 3855 1998 2.5 2.5 48.4 4930 3074 0.5X40 2.4 46.1 4661 2804 526 367 735 526
400 5.5 2.4 43 4877 2402 2.5 2.6 51.4 6027 3552 0.5X40 2.5 49.1 5739 3264 590 413 845 606
500 5.5 2.5 45.9 5899 2805 2.5 2.7 54.3 7122 4028 0.5X40 2.6 52.2 6843 3749 667 452 956 684
630 5.5 2.6 49.6 7224 3326 2.5 2.9 58.2 8571 4672 0.5X40 2.8 56.2 8269 4371 756 505 1083 780
ISO 9001:2008 DESCRIPTION: Three core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/ Steel wire armoured / steel strip armoured, and PVC outer sheathed cable
STANDARD: BDS-IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRGY/A2XSEYRGY 2XSEYFGY/A2XSEYFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
64 3X35 5.5 2.7 54.5 3923 3260 2.5 2.9 60 6497 5834 0.5X40 2.8 57.3 5215 4552 154 110 172 132
3X50 5.5 2.8 57.1 4582 3635 2.5 3 62.5 7277 6331 0.5X40 2.9 59.9 5936 4989 181 130 205 158
3X70 5.5 2.9 60.8 5489 4164 2.5 3.1 66.2 8361 7035 0.5X40 3 63.6 6932 5607 220 158 253 198
3X95 5.5 3 64.9 6590 4791 2.5 3.2 70.3 9659 7861 0.5X40 3.1 67.9 8169 6370 263 168 307 236
3X120 5.5 3.1 68.4 7651 5379 3.15 3.4 75.4 11768 9496 0.5X40 3.2 71.2 9281 7009 298 214 352 270
3X150 5.5 3.3 72.2 8923 6082 3.15 3.5 78.9 13218 10378 0.5X40 3.3 74.8 10602 7761 332 239 397 302
3X185 5.5 3.4 76.1 10322 6819 3.15 3.6 82.8 14852 11249 0.5X50 3.5 79.3 12315 8812 374 270 453 348
3X240 5.5 3.6 82.1 12609 8065 3.15 3.8 88.9 17502 12958 0.5X50 3.7 85.5 14808 10264 431 311 529 408
3X300 5.5 3.8 87.5 14966 9285 3.15 4 94.5 20191 14511 0.5X50 3.8 91 17268 11588 482 351 599 448
3X400 5.5 4 94.6 18651 11077 3.15 4.2 101.4 24290 16716 0.5X50 4 97.8 21137 13563 541 402 683 522
ISO 9001:2008 DESCRIPTION: Single core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed,
Un-armoured/ AL. wire armoured /AL. Double Tape armoured, and PVC outer sheathed cable
STANDARD: BDS - IEC 60502 (2)
APPLICATION: Can be used in Cable ducts or Tray or underground in power switching station, in Industrial plants, in Commercial
buildings and local distribution systems. Temp. Range = -20°C to +90°C
Nominal Nom. UNARMOURED ROUND WIRE(AL) ARMOURED DOUBLE TAPE(AL)ARMOURED CURRENT RATING
size thick 2XSEY/A2XSEY 2XSEYRaY/A2XSEYRaY 2XSEYBaY/A2XSEYBaY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight of cable armour thick of overall Weight of cable of thick overall Weight 30°C in ground 35°C in air
of outer diameter wire outer diameter armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
65 50 8 2 32.2 1384 1075 2 2.2 39.2 2101 1792 0.5X40 2.1 38.1 2054 1745 211 140 222 174
70 8 2 33.8 1634 1201 2 2.3 41 2406 1972 0.5X40 2.2 40 2356 1923 261 169 276 216
95 8 2.1 35.8 1957 1369 2 2.3 42.8 2748 2160 0.5X40 2.3 42 2717 2129 309 202 339 264
120 8 2.2 37.6 2270 1527 2 2.4 44.5 3097 2354 0.5X40 2.3 43.5 3041 2299 352 228 396 303
150 8 2.2 39 2594 1671 2.5 2.5 47.1 3623 2695 0.5X40 2.4 44.9 3398 2469 395 254 452 342
185 8 2.3 40.9 3011 1866 2.5 2.5 49.2 4108 2964 0.5X40 2.4 47.2 3896 2451 446 286 523 392
240 8 2.3 43 3605 2120 2.5 2.6 51.6 4784 3299 0.5X50 2.5 49.6 4560 3075 515 328 617 462
300 8 2.4 45.7 4277 2420 2.5 2.7 54.2 5523 3666 0.5X50 2.6 52.2 5286 3429 581 367 705 526
400 8 2.5 48.7 5327 2852 2.5 2.8 57.2 6650 4175 0.5X50 2.7 55.2 6398 3923 665 413 793 606
500 8 2.6 51.6 6376 3282 2.5 2.9 60.6 7838 4733 0.5X50 2.8 58.6 7569 4476 735 452 941 684
630 8 2.7 55.3 7736 3838 2.5 3 64.3 9297 5398 0.5X50 2.9 62.3 9010 5112 837 502 1085 780
ISO 9001:2008 DESCRIPTION: Three core, Copper/Aluminum Conductor, Screened, XLPE Insulated, Screened, Copper taped, PVC inner sheathed, Un-
armoured/ Steel wire armoured / steel strip armoured, and PVC outer sheathed cable
Nominal Nom. UNARMOURED ROUND STEEL WIRE ARMOURED FLAT STEEL WIRE ARMOURED CURRENT RATING
size thick 2XSEYY/A2XSEYY 2XSEYRGY/A2XSEYRGY 2XSEYFGY/A2XSEYFGY
of of
conductor Insulation Nom. Approx. Approx. Size of Nom. Approx. Approx. Size Nom. Approx. Approx.
thick Overall Weight armour thick of overall Weight of thick overall Weight 30°C in ground 35°C in air
of outer diameter of cable wire outer diameter of cable armour of outer diameter of cable
sheath CU AL sheath CU AL strip sheath CU AL CU AL CU AL
mm² mm mm mm kg/km kg/km mm mm mm kg/km kg/km mm mm mm kg/km kg/km amps amps amps amps
66 3X50 8 3.2 71 6378 5431 0.8X4 3.5 77.6 10586 9639 0.8X4 3.3 73.9 8953 8007 206 130 214 158
3X70 8 3.3 74.7 7384 6058 0.8X4 3.6 81.3 11809 10484 0.8X4 3.4 77.5 10131 8806 254 158 265 198
3X95 8 3.5 79 8636 6837 0.8X4 3.7 85.4 13264 11466 0.8X4 3.6 82.4 11642 9843 305 168 325 230
3X120 8 3.6 82.6 9794 7522 0.8X4 3.8 88.9 14631 12354 0.8X4 3.7 86 12978 10705 341 214 370 270
3X150 8 3.7 85.7 11043 8203 0.8X4 3.9 92 16062 13222 0.8X4 3.8 89.1 14391 11551 356 239 425 302
3X185 8 3.9 89.8 12589 9086 0.8X4 4.1 96.1 17837 14334 0.8X4 3.9 93 16088 12585 428 270 490 348
3X240 8 4 95.2 14899 10354 0.8X4 4.2 101.5 20467 15923 0.8X4 4.1 98.6 18761 14217 494 311 565 408
3X300 8 4.2 100.8 17316 11715 0.8X4 4.4 107 23286 17605 0.8X4 4.3 104.2 21586 15906 532 351 595 448
3X400 8 4.4 107.3 21148 13574 0.8X4 4.6 113 27413 19839 0.8X4 4.5 110.7 25716 18143 610 402 720 522
APPLICATION: Used for industrial signalling and process circuit control in dry and wet
locations also suitable for ship board application.
CONSTRUCTION: Plain stranded copper (as per class 2 of IEC-228) conductor, FR PVC/XLPE
Insulated in White colour with numbers, cores laidup with polyester binder, covered with or
without AMT and plain/tinned copper drain wire and Extruded black ST2 PVC outer
sheathed cable.
TECHNICAL DATA: Voltage grade = 600/1000V Temperature range = -20°C to +90°C
B. R. = 12X Cable Ø
Cable PVC UNSHEILEDED PVC OVERALL SHEILEDED XLPE UNSHEILDED XLPE OVERALL SHEILDED
size Core Sh. App. App. Sh. App. App. Core Sh. App. App. Sh. App. App.
dia thick O.D. Wt. thick O.D. Wt. dia. thick O.D. Wt. thick O.D. Wt.
mm2 mm mm mm kg/km mm mm kg/km mm mm mm kg/km mm mm kg/km
1.0X 2C 2.7 1.1 8.2 85 1.1 8.5 90 2.5 1.1 7.5 65 1.1 7.8 70
(7/0.42) 3C 2.7 1.1 8.6 100 1.1 8.9 105 2.5 1.1 7.9 75 1.1 8.2 80
4C 2.7 1.1 9 120 1.1 9.3 125 2.5 1.1 8.5 90 1.1 8.8 95
5C 2.7 1.1 9.6 130 1.1 9.9 135 2.5 1.1 9.1 105 1.1 9.4 115
7C 2.7 1.1 10.5 165 1.1 10.8 170 2.5 1.1 10 135 1.1 10.4 145
10C 2.7 1.1 13.5 220 1.1 13.8 230 2.5 1.1 12.5 185 1.1 12.9 195
14C 2.7 1.2 15 300 1.2 15.3 310 2.5 1.2 13.7 245 1.2 14.1 260
19C 2.7 1.3 16.5 405 1.3 16.9 415 2.5 1.3 15.4 325 1.3 15.8 350
24C 2.7 1.4 19.7 505 1.4 20 515 2.5 1.4 18.2 420 1.4 18.6 440
1.5X2C 3.2 1.1 8.9 90 1.1 9.1 95 3 1.1 8.6 85 1.1 8.8 90
(7/0.52) 3C 3.2 1.1 9.4 120 1.1 9.6 125 3 1.1 9 100 1.1 9.3 105
4C 3.2 1.1 10.2 140 1.1 10.4 148 3 1.1 9.8 125 1.1 10.1 130
5C 3.2 1.1 10.8 165 1.1 11.1 175 3 1.1 10.5 150 1.1 10.8 155
7C 3.2 1.1 12.2 220 1.1 12.4 228 3 1.1 11.5 200 1.1 11.8 210
10C 3.2 1.2 15.8 300 1.2 16.2 23 3 1.2 14.7 265 1.2 15 275
14C 3.2 1.2 17.5 400 1.2 17.8 415 3 1.2 16 370 1.2 16.4 380
19C 3.2 1.3 18.9 540 1.3 19.2 555 3 1.3 18 470 1.3 18.4 485
24C 3.2 1.4 23 680 1.4 23.3 698 3 1.4 21.1 590 1.4 21.5 605
2.5X2C 3.7 1.1 10 145 1.1 11.3 150 3.5 1.1 9.5 110 1.1 9.8 115
(7/0.67)3C 3.7 1.1 10.6 175 1.1 11.9 180 3.5 1.1 10.1 138 1.1 10.4 145
4C 3.7 1.1 11.1 215 1.1 13 225 3.5 1.1 11 170 1.1 11.3 175
5C 3.7 1.1 12.3 255 1.1 15 275 3.5 1.1 11.8 210 1.1 12.1 218
7C 3.7 1.2 14 335 1.2 16.3 355 3.5 1.2 13.2 280 1.2 13.5 290
10C 3.7 1.2 17.6 460 1.2 20.5 475 3.5 1.2 16.8 395 1.2 17.2 405
14C 3.7 1.3 19.4 615 1.3 24 625 3.5 1.3 18.5 525 1.3 18.9 535
19C 3.7 1.4 21.8 810 1.4 25.8 825 3.5 1.4 20.7 705 1.4 21.1 720
APPLICATION: Used for industrial signalling and process circuit control in dry and wet
locations also suitable for ship board application.
CONSTRUCTION: Plain stranded copper (as per class 2 of IEC-228) conductor, FR PVC/XLPE
Insulated in colour code of white and Black with pair number on white core, all pairs are
twisted to counter electromagnetic noise, and twisted pairs are assembled with polyester
tape and with or without AMT with plain/tinned copper drain wire and Extruded black ST2
PVC outer sheathed cable
Cable PVC UNSHEILEDED PVC OVERALL SHEILEDED XLPE UNSHEILDED XLPE OVERALL SHEILDED
size Core Sh. App. App. Sh. App. App. Core Sh. App. App. Sh. App. App.
dia thick O.D. Wt. thick O.D. Wt. dia. thick O.D. Wt. thick O.D. Wt.
mm2 mm mm mm kg/km mm mm kg/km mm mm mm kg/km mm mm kg/km
1.0X 1P 2.7 1.1 8.3 85 1.1 8.4 93 2.5 1.1 7.8 70 1.1 8 78
(7/0.42) 2P 2.7 1.1 12.8 125 1.1 12.9 135 2.5 1.1 11.9 95 1.1 12 108
3P 2.7 1.1 13.9 155 1.1 14 165 2.5 1.1 13.1 125 1.1 13 135
4P 2.7 1.1 15.7 180 1.1 15.9 190 2.5 1.1 14.9 150 1.1 14.9 160
6P 2.7 1.1 18.2 265 1.1 18.5 275 2.5 1.1 17.1 220 1.1 17.1 230
10P 2.7 1.2 21.6 445 1.2 21.9 460 2.5 1.1 20.2 355 1.1 20.4 365
14P 2.7 1.2 25.9 600 1.2 26.3 615 2.5 1.1 23.2 500 1.2 23.5 510
20P 2.7 1.2 29.3 815 1.2 29.8 830 2.5 1.2 27.5 670 1.2 27.8 680
24P 2.7 1.3 31.7 970 1.3 31.7 985 2.5 1.3 30.2 875 1.4 29.6 890
1.5X1P 3.2 1.1 8.9 95 1.1 8.9 103 3 1.1 8.4 90 1.1 8.4 98
(7/0.52) 2P 3.2 1.1 14.6 130 1.1 14.7 140 3 1.1 13.1 135 1.1 13 132
3P 3.2 1.1 15.8 155 1.1 15.9 165 3 1.1 14.8 180 1.1 14.1 190
4P 3.2 1.1 17 180 1.1 17 190 3 1.1 16.4 230 1.1 16 240
6P 3.2 1.1 19.8 355 1.1 20 365 3 1.1 18.8 315 1.1 18.5 325
10P 3.2 1.2 23.3 565 1.2 23.8 575 3 1.1 22.3 490 1.2 22.3 505
14P 3.2 1.2 27.6 830 1.2 28 840 3 1.2 26.2 720 1.2 25.8 735
20P 3.2 1.3 32 1140 1.3 32.3 1155 3 1.3 29.9 980 1.4 23.9 995
24P 3.2 1.4 34.6 1360 1.4 34.9 1375 3 1.4 33.1 1155 1.5 32.4 1170
2.5X1P 3.7 1.1 11.2 150 1.1 11.2 158 3.5 1.1 9.8 115 1.1 9.7 123
(7/0.67)2P 3.7 1.1 18.7 220 1.1 18.7 230 3.5 1.1 16.2 175 1.1 16 188
3P 3.7 1.1 20.4 300 1.1 19.7 310 3.5 1.1 17.6 250 1.1 17.4 260
4P 3.7 1.1 23.1 380 1.1 23.1 390 3.5 1.1 18.9 310 1.2 18.8 320
6P 3.7 1.2 26.9 540 1.2 26.9 555 3.5 1.2 23 465 1.2 22.9 475
10P 3.7 1.2 31.6 910 1.2 32.1 925 3.5 1.2 26.4 810 1.3 26.8 825
14P 3.7 1.2 36.3 1135 1.3 36.3 1140 3.5 1.3 30.6 1050 1.3 30.6 1065
APPLICATION: Used for industrial signalling and process circuit control in dry and wet
locations also suitable for ship board application.
CONSTRUCTION: Plain stranded copper (as per class 2 of IEC-228) conductor, FR PVC/XLPE
Insulated, colour code of white,Black and Red with traid number on white core, all Triples
are twisted to counter electromagnetic noise, and twisted Triples are assembled with
polyester tape and with or without AMT with plain/tinned copper drain wire and Extruded
black ST2 PVC outer sheathed cable
TECHNICAL DATA: Voltage grade = 600/1000V Temperature range = -20°C To +90°C
B. R. = 12X Cable Ø!
Cable PVC UNSHEILEDED PVC OVERALL SHEILEDED XLPE UNSHEILDED XLPE OVERALL SHEILDED
size Core Sh. App. App. Sh. App. App. Core Sh. App. App. Sh. App. App.
dia thick O.D. Wt. thick O.D. Wt. dia. thick O.D. Wt. thick O.D. Wt.
mm2 mm mm mm kg/km mm mm kg/km mm mm mm kg/km mm mm kg/km
1.0X 1T 2.7 1.1 8.8 105 1.1 8.9 115 2.5 1.1 8.2 80 1.1 8.3 90
(7/0.42) 2T 2.7 1.1 15.5 150 1.1 15.7 165 2.5 1.1 14.5 125 1.1 14.6 135
3T 2.7 1.1 16.5 210 1.1 16.7 225 2.5 1.1 15.3 180 1.1 15.5 190
4T 2.7 1.1 17.9 280 1.1 18.1 330 2.5 1.1 16.7 235 1.1 16.9 245
6T 2.7 1.1 22.8 405 1.1 23.2 425 2.5 1.1 20.3 320 1.1 20.6 335
10T 2.7 1.2 26.6 645 1.2 26.9 670 2.5 1.1 24.8 535 1.1 25.1 550
14T 2.7 1.2 30.2 875 1.2 30.5 900 2.5 1.1 28.3 705 1.2 28.5 720
20T 2.7 1.2 35.5 1240 1.2 38.9 1265 2.5 1.2 32.8 970 1.2 33.1 990
24T 2.7 1.3 38.5 1480 1.3 38.7 1500 2.5 1.3 35.5 1220 1.4 35.8 1240
1.5X1T 3.2 1.1 9.4 125 1.1 9.5 135 3 1.1 8.9 110 1.1 8.9 120
(7/0.52) 2T 3.2 1.1 16.8 155 1.1 16.9 165 3 1.1 15.8 190 1.1 15.9 200
3T 3.2 1.1 17.9 290 1.1 18.1 265 3 1.1 16.7 250 1.1 16.9 260
4T 3.2 1.1 19.5 365 1.1 19.7 380 3 1.1 18.2 310 1.1 18.4 325
6T 3.2 1.1 24.9 540 1.1 25.1 555 3 1.1 23.3 455 1.1 23.5 470
10T 3.2 1.2 29.1 905 1.2 29.3 920 3 1.1 27.3 770 1.2 27.5 790
14T 3.2 1.2 33.3 1250 1.2 33.6 1265 3 1.2 31.3 1050 1.2 31.5 1070
20T 3.2 1.3 38.9 1710 1.3 39.2 1730 3 1.3 36.2 1460 1.4 36.5 1485
24T 3.2 1.4 42.2 2020 1.4 42.4 2040 3 1.4 39.2 1730 1.5 40.2 1755
2.5X1T 3.7 1.1 11.9 185 1.1 11.9 195 3.5 1.1 10.3 145 1.1 10.4 155
(7/0.67)2T 3.7 1.1 22.8 320 1.1 22.9 330 3.5 1.1 18.5 260 1.1 18.6 270
3T 3.7 1.1 24.2 430 1.1 24.4 440 3.5 1.1 19.7 390 1.1 19.9 405
4T 3.7 1.1 26.4 565 1.1 26.8 580 3.5 1.1 22.5 510 1.2 22.8 525
6T 3.7 1.2 32.5 815 1.2 32.8 830 3.5 1.2 27.4 700 1.2 27.8 715
10T 3.7 1.2 37.6 1260 1.2 37.9 1285 3.5 1.2 32.6 1160 1.3 32.9 1180
14T 3.7 1.2 44.2 1750 1.3 44.5 1770 3.5 1.3 36.8 1550 1.3 37.1 1570
APPLICATION: Used for industrial signalling and process circuit control in dry and wet
locations also suitable for ship board application.
CONSTRUCTION: Plain stranded copper (as per class 2 of IEC-228) conductor, FR PVC/XLPE
Insulated, colour code of white,Black and Red with traid number on white core, all Triples
are twisted to counter electromagnetic noise, and twisted Triples are assembled with
polyester tape and with or without AMT with plain/tinned copper drain wire and Extruded
black ST2 PVC outer sheathed cable
TECHNICAL DATA: Voltage grade = 600/1000V Temperature range = -20°C To +90°C
B. R. = 12X Cable Ø!
Cable size PVC PAIR/TRIAD INDIVIDUAL AND OVERALL SHEILDED XLPE PAIR/TRIAD INDIVIDUAL AND OVERALL SHEILDED
PAIRS TRIPLES PAIRS TRIPLES
Core Sh. App. App. Sh. App. App. Core Sh. App. App. Sh. App. App.
dia thick O.D. Wt. thick O.D. Wt. dia. thick O.D. Wt. thick O.D. Wt.
mm2 mm mm mm kg/km mm mm kg/km mm mm mm kg/km mm mm kg/km
2X1.0P/T 2.7 1.1 13.3 140 1.1 16.1 160 2.5 1.1 12.4 115 1.1 15.1 145
3X1.0P/T 2.7 1.1 15.2 175 1.1 17.1 230 2.5 1.1 13.5 145 1.1 16.5 200
4X1.0P/T 2.7 1.1 16.4 205 1.2 18.6 300 2.5 1.1 15.3 175 1.2 17.6 260
6X1.0P/T 2.7 1.2 19.1 295 1.2 23.8 440 2.5 1.2 17.7 245 1.2 22.2 350
10X1.0P/T 2.7 1.2 22.1 590 1.3 27.8 695 2.5 1.2 22.1 385 1.3 25.6 580
14X1.0P/T 2.7 1.2 26.5 870 1.3 32.1 930 2.5 1.2 24.3 530 1.3 29.3 750
20X1.0P/T 2.7 1.3 30.7 1190 1.4 37.1 1295 2.5 1.3 28.5 700 1.4 34.4 1020
24X1.0P/T 2.7 1.4 33.2 1425 1.5 40.2 1540 2.5 1.4 30.6 930 1.5 37.2 1280
2X1.5P/T 3.2 1.1 14.4 145 1.1 17.4 180 3 1.1 13.5 120 1.1 16.4 210
3X1.5P/T 3.2 1.1 16.4 185 1.1 18.5 280 3 1.1 15.5 150 1.1 17.4 275
4X1.5P/T 3.2 1.1 17.7 210 1.2 20.2 395 3 1.1 16.7 180 1.2 18.9 340
6X1.5P/T 3.2 1.2 20.6 370 1.2 25.8 570 3 1.2 19.3 335 1.2 24.2 490
10X1.5P/T 3.2 1.2 24.4 595 1.3 30.1 950 3 1.2 23.1 525 1.3 28.1 820
14X1.5P/T 3.2 1.3 28.6 870 1.3 34.5 1290 3 1.3 28.2 760 1.3 32.6 1110
20X1.5P/T 3.2 1.3 33.4 1220 1.4 40.4 1770 3 1.3 31.2 1025 1.4 37.8 1520
24X1.5P/T 3.2 1.4 36.1 1420 1.5 47.2 2075 3 1.4 33.8 1220 1.5 40.6 1800
2X2.5P/T 3.7 1.1 18.3 245 1.1 23.4 340 3.5 1.1 16.6 210 1.1 19.1 295
3X2.5P/T 3.7 1.1 19.8 320 1.1 24.9 450 3.5 1.1 18.1 285 1.1 20.4 430
4X2.5P/T 3.7 1.1 22.6 415 1.2 27.2 620 3.5 1.1 19.5 355 1.2 23.2 560
6X2.5P/T 3.7 1.2 27.6 580 1.3 33.4 865 3.5 1.2 23.8 515 1.3 28.4 760
10X2.5P/T 3.7 1.3 32.8 945 1.4 39.2 1320 3.5 1.3 27.3 885 1.4 33.1 1250
14X2.5P/T 3.7 1.4 37.6 1175 1.5 43.3 1810 3.5 1.4 32.1 1155 1.5 38.1 1670
VDE - 0815
APPLICATION: Suitable for data processing and process control. The individual shielding
of pairs results in high crosstalk attenuation. Over-all copper braid protects screened
pairs from outer electrostatic noise. Low level of attenuation and low mutual capacitance
enable long transmission distances. Cable can be used for fixed installation in dry and
wet locations.
CONSTRUCTION: Stranded plain copper (as per class 2 of IEC-228) conductor, PE
insulated in black and white colour cores twisted into pairs. Each pair is shielded with
AMT and tinned copper drain wire by providing numbered tape for pair identification.
Shield pairs are cabled with fillers (if necessary) covered with polyester tape and
braided with plain copper wires, and grey colour FR (as per IEC 332-1) outer sheathed.
TECHNICAL DATA:
Working Voltage (max) 300V
Temperature range -20°C to +80°C
Mutual Capacitance(pF/km) 85 nF/km
Inductance 0.75mH/km
Test voltage 1000V core/core and core/screen
Insulation resistance 5 G ohm-km
Attenuation 1.1 dB/km at 800Hz and 3.0 dB/km at 10 KHz
Minimum bending radius 7.5 X Cable diameter
MANUFACTURING DATA:
Pairs Strand x dia. Insulation thick Sheath thick Approx. O.D Approx. Wt.
No x mm mm mm mm Kg/km
2 7x0.3 0.3 1.0 9.8 120
4 7x0.3 0.3 1.0 10.5 160
8 7x0.3 0.3 1.2 14.4 280
12 7x0.3 0.3 1.2 16.1 370
16 7x0.3 0.3 1.6 18.9 490
20 7x0.3 0.3 1.6 20.6 585
24 7x0.3 0.3 1.6 22.1 675
32 7x0.3 0.3 1.6 24.8 850
36 7x0.3 0.3 1.6 26.1 935
40 7x0.3 0.3 1.6 27.2 1020
48 7x0.3 0.3 1.8 29.8 1215
VDE - 0250
APPLICATIO N: These cables are used as signal cables in the field of electronics,
computer systems and various control systems such as tool making and machine
industries. Copper wire screen provides interference-free signal transmission. The
absence of inner sheath has the advantage of lower cable diameter and reduced
bending radius.
CONSTRUCTION: Plain copper conductor (class 5 of IEC-228), PVC (VDE 0207) insulated
Black cores with white numbers and one green/yellow core. Cores twisted in layers,
wrapped with polyester binder and braided with plain copper wires with 60%
coverage. Black FR sheath (VDE 0207/IEC 332-1) is provided for outer coating.
TECHNICAL DATA: Working Voltage: 300/500V Temperature range: -20°C to +80°C Mutual Cap.=
core/core 150nF/km and core/screen 280nF/km; Inductance = 0.7mH/km; Insulation Resistance=
20MOhm - km; Test voltage = 2000V. for 5Minutes.
MANUFACTURING DATA:
Cable size = 0.75 mm²(24/0.2) 1.0 mm²(32/0.2)
cores Ins. Thick Sh. Thick App. O.D. APP. Ins. Thick Sh. Thick App.O.D. App.Wt.
No. mm mm mm Wt. mm mm mm kg/km
3 0.6 0.8 7.8 90 0.6 1.0 8.5 110
4 0.6 1.0 8.8 115 0.6 1.0 9.2 130
5 0.6 1.0 9.4 135 0.6 1.0 9.9 155
6 0.6 1.0 10.2 155 0.6 1.2 11.1 190
7 0.6 1.0 10.2 160 0.6 1.2 11.1 195
10 0.6 1.2 12.9 230 0.6 1.2 13.6 265
12 0.6 1.2 13.5 275 0.6 1.2 14.3 315
14 0.6 1.2 14.1 305 0.6 1.5 14.9 355
19 0.6 1.2 15.5 380 0.6 1.5 17.0 465
24 0.6 1.8 19.1 520 0.6 1.8 20.2 600
27 0.6 1.8 19.5 560 0.6 1.8 20.6 650
30 0.6 1.8 20.1 605 0.6 1.8 21.2 705
37 0.6 1.8 21.5 705 0.6 1.8 22.7 830
48 0.6 2.1 24.9 910 0.6 2.1 26.3 1070
APPLICATION: These cables are used for Data Transmission in Computer Net Work
systems. Category -3 cables used up to 16MB/S, Category -4 cables used up to 20MB/S
and Category-5 cables used up to 100MB/S.
CONSTRUCTION: Solid copper conductor, Polyethylene insulated, Colour coded, Cores
twisted into pairs and cabled together and PVC Outer sheathed normally in Grey colour.
MANUFACTURING DATA:
Category Insulation Sheath Nom. Standard Approx.
Cond. Dia.
Code Thickness thickness O.D. length weight
mm mm mm mm mtrs Kg.
Cat - 3 0.51 0.17 0.6 5.0 305 9.1
Cat - 4 0.51 0.20 0.6 5.3 305 9.8
Cat - 5 0.51 0.23 0.6 5.7 305 10.3
COLOUR CODE:
No. a-wire b-wire No. a-wire b-wire !No. a-wire b-wire
of of of
pairs pairs pairs
MANUFACTURING DATA:
Pair No's x dia. Ins. Thick AMT Shield cable AMT and BRAID cable
Nos. No.xmm (EIA RS-232) (EIA RS-422)
Sh.Thick App .O.D. App. Wt. Sh.thick App. OD. App. Wt.
APPLICATION: 3 core flat submersible cables are idle for usage in submersible pumps in
deep wells for irrigation, drinking water supply, industries, mines, fountains. Whereas
Heavy duty 3 core round submersible cables are best suited for application like sewage,
slurry, offshore drilling rigs, sea water handling, mine dewatering etc.
CONSTRUCTION: Plain Copper Flexible conductor (as per class -V of IEC 60228), PVC
TECHNICAL DATA: Voltage grade: - 0.6/1(1.2) KV TEMP. RANGE: - -15°C to 70°C
B. R: 8 x CABLE DIA.
MANUFACTURING DATA
Round Submersible cable Flat Submersible Cable
Cable No. / Dia. Nom. Current
Size of wire Thick Nom. App. App. Nom. App. App. Rating
of Thick Overall Weight Thick Overall Weight At
Insulation of Sheath Dia. of cable of Sheath size of of cable 35°C
of cable cable
mm² mm mm mm mm Kg/km mm mm Kg/km amps
3CX1.5 20/0.3 0.8 1.4 9.8 144 1.2 5.8x12.3 134 16
3CX2.5 32/0.3 0.8 1.4 10.8 189 1.2 6.4x14.0 180 20
3CX4 50/0.3 1.0 1.6 13.0 272 1.4 7.2x16.3 252 26
3CX6 80/0.3 1.0 1.6 14.6 361 1.4 8.1x18.7 345 34
3CX10 72/0.4 1.0 1.8 17.6 567 1.6 9.5x22.5 520 46
3CX16 118/0.4 1.0 1.8 20.8 828 1.6 11.4x27.4 785 63
3CX25 185/0.4 1.2 2.0 25.7 1270 1.8 14.3x34.5 1205 80
3CX35 260/0.4 1.2 2.0 28.0 1639 1.8 15.5x38.1 1580 99
3CX50 370/0.4 1.4 2.2 33.4 2279 2.0 18.0x45.4 2195 126
3CX70 335/0.495 1.4 2.2 37.7 3030 2.0 19.9x50.5 2910 157
3CX95 455/0.495 1.6 2.4 43.5 4060 2.2 23.0x59.0 3920 180
mm mm mm kg/km
2 core (1 pair) 1/0.60 0.787 4.11 x 2.31 19.0
2 core (1 pair) 1/0.90 1.05 6.3 x 3.0 31.5
mm mm mm kg/km
2 core (1 pair) 1/0.60 0.787 4.11 x 2.31 12.00
2 core (1 pair) 1/0.90 1.05 6.3 x 3.0 25.00
mm2 mm mm mm mm kg/km
2 core!(1 pair) 0.123 9/0.132 0.381 0.915 4.11 21.55
4 core!(2 pair) 0.123 9/0.132 0.381 0.915 4.21 24.04
6 core!(3 pair) 0.123 9/0.132 0.381 0.915 4.75 31.80
DUPLEX CABLES:
DESCRIPTION: Copper / Aluminum conductor, PVC insulated, two cores laid up. In case of
copper conductor one core shall be hard drawn.
APPLICATION: Suitable for use as a service drop cable for single phase connection.
Voltage Grade: 600 / 1000V Temp. Range: -15°C to 70°C
Cross No. and Nom. Thickness App. Cable App. Weight of cable Current rating at 35°C
sectional area diameter of insulation diameter
of wires in metal conduit In air
mm² No./mm mm mm Cu Al Cu Al
2.5re / 2.5re 1.78 / 1.78 1.60 10.0 93 - 27 -
4rm / 4re 7x0.85 / 2.26 1.60 11.6 132 - 35 -
6rm / 6re 7x1.04 / 2.77 1.60 12.8 178 - 45 -
6rm / 6rm 7x1.04 / 7x1.04 1.60 12.9 180 105 45 37
10rm / 10rm 7x1.35 / 7x1.35 1.60 14.6 262 136 62 47
16rm / 16rm 7x1.70 / 7x1.70 1.60 16.6 382 180 84 65
25rm / 25rm 7x2.14 / 7x2.14 1.60 19.2 563 244 110 85
QUADRUPLEX CABLES:
DESCRIPTION: Copper / Aluminum conductor, PVC insulated, four cores laid up. In case of
copper conductor one core shall be hard drawn.
APPLICATION: Suitable for use as a service drop cable for Three phase connection.
Voltage Grade: 600 / 1000V Temp. Range: -15°C to 70°C
Cross No. and Nom. Thickness App. Cable App. Weight of cable Current rating at 35°C
sectional area diameter of insulation diameter
of wires in metal conduit In air
mm² No./mm mm mm Cu Al Cu Al
3x4rm / 4re 7x0.85 / 2.26 1.60 14.0 264 - 32 -
3x6rm / 6re 7x1.04 / 2.77 1.60 15.4 352 - 41 -
3x6rm / 6rm 7x1.04 / 7x1.04 1.60 15.5 356 2.5 41 34
3x10rm / 10rm 7x1.35 / 7x1.35 1.60 17.6 524 270 56 43
3x16rm / 16rm 7x1.70 / 7x1.70 1.60 20.0 765 360 75 58
3x25rm / 25rm 7x2.14 / 7x2.14 1.60 23.1 1127 488 98 76
APPLICATION: These cables are required to function even under fire conditions for a
reasonable length of time to enable safe evacuation of people and to extend emergency
services. Especially suitable for smoke detection, alarm system, and installation of cables in
crowed buildings, hospitals, hotels, underground railways, airports etc.
CONSTRUCTION: Annealed plain copper conductor as per IEC-228, FRLS PVC insulated over
Flame barrier Mica Tape, laid up and FRLS PVC outer sheathed in RED colour.
TECHNICAL DATA:
Temperature Range! : -20°C to 90°C Fire Resistant Property
Working Voltage! : 300/500 V 750°C for three hours to IEC-331
Test Voltage! : 1000 V for 1 min. Flame retardant to IEC- 332-1
Colour Code ! : Red, yellow, blue & black Flame retardant to IEC-332-3
Passes Low Smoke Test to IEC-1034
SINGLE CORE CABLES FOR INSTALLATION IN BUILDINGS, POWER PLANTS & REFINERIES
Nom. Area Class of Thickness Overall App. Weight Current Rating
of conductor conductor of insulation diameter of cable
mm² As per IEC mm mm Kg/km amps
1.5 5 1.1 3.5 23 26
2.5 5 1.1 4.1 35 35
4.0 5 1.1 4.7 50 46
6.0 5 1.1 5.3 70 58
10.0 5 1.3 6.6 114 79
APPLICATION: These cables are suitable for all electrical installations in dry and humid
locations, under industrial conditions. Applications include steel mills, machine tool
manufacture and similarly where cable is required to work under moving conditions.
CONSTRUCTION: Annealed plain copper conductor as per class-5 of IEC-228, PVC
insulated, colour coded, cores laid flat and PVC outer sheathed as per BS-6746 with colour
normally in Black.
TECHNICAL DATA:
Temperature Range! :! -15°C to 70°C
Working Voltage! :! 450 / 750 V
Core identification! :! One core Yellow-Green and balance all numbered with
! !! ! black colour insulation
Cable Size No./Dia. Of wire Nom. Thick Nom. Thick App. Overall size App. Weight Current Rating
of insulation of sheath of size of cable of cable
mm² mm mm mm mm Kg/km amps
4CX1.5 20/0.3 0.8 1.8 16.9 x 7.0 216 16
8CX1.5 20/0.3 0.5 1.9 30.3 x 7.0 395 15
12CX1.5 20/0.3 0.5 2.3 44.2 x 7.0 580 14
4CX2.5 32/0.3 0.5 1.8 18.5 x 7.4 273 20
8CX2.5 32/0.3 0.5 2.0 33.6 x 7.4 505 19
12CX2.5 32/0.3 0.5 2.4 49.2 x 7.4 660 18
4CX4.0 50/0.3 1.0 1.8 21.7 x 8.2 375 26
8CX4.0 50/0.3 1.0 2.2 40.4 x 8.2 714 25
12CX4.0 50/0.3 1.0 2.8 59.6 x 8.2 1060 24
Note: Other Sizes and combination of different cores also can be supplied on demand.
Sales Office:
Chittagong : Dominion Plaza, 5 Jubilee Road. Tel: 031-617 928, 0171-311 2346 Fax: 031-617 928
Cox'sbazar : Dakkhin Tekpara, Main Road, Kalur Dokan. Tel: 0341-52008, 0173-031 3026
Noakhali : Kiron Imperial, 1460 Karimpur Road, Chowmohani. Tel: 0173-000-1251
Comilla : 102/97 Rezia Manjil, Trunk Road, Chalk bazar. Tel: 081-721-92, 0171-336-6984
Sylhet : Purbani Shopping Complex (1st floor), East Zindabazar. Tel: 0821-723-461, 0171-199-5114
Moulvibazar : Haji Abdul Matin Khan Complex, 127 Syed Mujtaba Ali Sarak. Tel: 0171-336-7004
Bogra : 164 Abdul Jabbar Road, Jaleshwaritala. Tel: 051-632-70, 0171-184-9573 Fax: 051-652-40
Rajshahi : G-166 Sultanabad, Station Road. Tel: 0721-774-920, 0171-336-7012
Rangpur : Central Road, Paira Chattar. Tel: 0521-677-57, 0171-336-6998
Dinajpur : 681/645/2 Munshipara, Dinajpur-5200 Tel: 0531-649-22, 0173-008-8095
Khulna : Hahnemann Bhaban, 24 Clay Road. Tel: 041-731-523, 0173-000-1258
Jessore : 7 M.M. Ali Road, Jessore Sadar. Tel: 0421-670-83, 0171-336-7009
Kushtia : 165 N.S. Road, Thanapara, Kushtia-7000. Tel: 0717-2225, 0171-336-6952
Faridpur : Hasina Tower, Mujib Sarak, Moirapatti. Tel: 0631-657-50, 0171-344-3083
Barisal : Municipal Super Market, Sadar Road. Tel: 0431-217-6854, 0171-333-0362
Mymensingh : Aziz Plaza (Ground floor), 7 CK Gosh Road. Tel: 091-629-78, 0171-336-6986, 0173-031-3025
Pabna : 783 Tati Samabaya Market, Abdul Hamid Road. Tel: 0731-630-53, 0171-336-7014
Chapai Nawabganj : 63 Sreeti Plaza, Boro Indara More. Godagari Road. Tel: 0781-517-57, 0171-336-7013
Tangail : CDC Market, Victoria Road. 0197-799-7730
Show Room
1. Paradise Electric : Tel. 711 6020, 0171 336 6963
2. Balaka Electric : Tel. 711 9246, 0191 134 7599
3. SBS Electric : Tel. 712 2598, 0171 336 6965
4. Reliance Electric : Tel. 712 2605, 0171 336 7034
5. Pacific Electric : Tel. 955 5590, 0171 314 4297
6. New paradise : Tel. 712 0447, 0171 336 6962
7. Gulshan : Tel. 881 8815, 0171 301 8713
8. Uttara : Tel. 895 8284, 0171 336 6978
9. Mirpur-10 : Tel. 806 0542, 0171 3443 075
10. Mirpur-1 : Tel. 901 4388, 0171 336 7029
11. Narayangonj : Tel. 764 9163, 0171 336 7017
12. Tongi : Tel. 981 5688, 0171 344 3082
13. Sreepur : Tel. 0171 337 1390, 0171 336 6964
14. Gazipur : Tel. 926 2020, 0191 770 2931
15. Green Road : Tel. 0171 336 7045
16. Bhulta : Tel. 0173 032 8432, 0171 336 7050
17. Bhasundhura : Tel. 841 1773, 0171 344 3069
18. Moghbazar : Tel. 0173 000 1252, 0171 336 6981
19. Ashulia : Tel. 0173 008 8094, 0171 336 7032
20. CEPZ : Tel. 0173 032 8736, 0197 336 6947
21. Khulna : Tel. 0171 336 7010, 0171 337 1388
22. Nandankanon : Tel. 0197 336 6954, 0171 189 1722
23. Kaptan Bazar-1 : Tel. 0171 336 6961, 0197 336 6957
24. Kaptan Bazar-2 : Tel. 0171 336 7030
25. Jatrabari : Tel. 0197 799 7741