Load Data For Lifting Lugs Given Data
Load Data For Lifting Lugs Given Data
Given data
load to be lifted = 400 kN
Impact factor = 25 %
Material of lug ASTM A 572 Grade 50
Yield strength = 345 Mpa
Number of top lugs = 2 No's
Number of bottom lugs = 4 No's