Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

P0381 GLOW CONTROL SYSTEM

< COMPONENT DIAGNOSIS > [K9K]

Glow relay ECM A


Continuity
Connector Terminal Connector Terminal
F94 8 F68 76 Existed
EC
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 5. C
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK GLOW RELAY OUTPUT CIRCUIT FOR OPEN AND SHORT
D
1. Disconnect glow plug harness connector.
2. Check the continuity between glow plug harness connector and ECM harness connector.

E
Glow relay Glow plug
Continuity
Cylinder Connector Terminal Connector Terminal
1 2 F95 1 F
2 7 F96 1
F94 Existed
3 1 F97 1
4 6 F98 1 G

3. Also check harness for short to ground and short to power.


Is the inspection result normal? H
YES >> GO TO 6.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
6.CHECK GLOW PLUG I
Refer to EC-1371, "Component Inspection".
Is the inspection result normal?
J
YES >> GO TO 7.
NO >> Replace malfunctioning glow plug.
7.CHECK INTERMITTENT INCIDENT K
Refer to GI-39, "Intermittent Incident".
Is the inspection result normal?
YES >> Replace glow relay. L
NO >> Repair or replace.
Component Inspection INFOID:0000000001091182
M
1.CHECK GLOW PLUG
1. Turn ignition switch OFF.
N
2. Disconnect glow plug harness connector.
3. Check resistance between glow plug terminals as follows.

O
Terminal Resistance
1 and engine ground Not less than 2Ω [at 20°C (68°F)]
Is the inspection result normal? P
YES >> INSPECTION END
NO >> Replace malfunctioning glow plug.

EC-1367

You might also like