Download as pdf
Download as pdf
You are on page 1of 1
@AlIcom 1c-ExX3o09s INTERFACE UNIT INSTRUCTION MANUAL “Thank you very much for purchasing our products ‘The IC EX300 isan interfaca unit that required to connect the options communiestion teminal(CT:10) with other ICOM product such a 10-751, 1C-271A/EIH, IC-A7TAIEIH, oF IC-RT1A/EID. Poste read ail the instructions fo that you ean instal i into the transctver/reesivereotrety to get maximum peefozmance and fll value from each st CONNECTION OF EACH TERMINAL AND ITS FUNCTION i) INSTALLATION PROCEDURE 1 Inetalltin to 10-751 1) Remove the top and bottom coves, 2) Remove the plate attached tothe reer panel and un the cables inward ‘The connector should be install with the screws that ware used to attach the 23) Install the connector onto where spe tied, and connect the cables fm the fongctor tothe unit 4) Plug the eabes into J10 and J15 of the LOGIC unit 5} Replace the top and bottom covers * For installtion to ICR}, refer to the Instruction Manual of the ICI recive. Fan —Faneton — Fureion 1_| Data bus BO input/output Notuwd [2] ost us D1 iputioutput Nt 3 | Bate bur 02 inpuout 15 Notun | 4 | Dat bus 03 inpuoutput 16 | Notuse [8 | nt tus ba opuoutpt aT] Nor uae Data bus D5 inpuvoutput 18 | Noted { Insaation to 16271AVE/H oF 7 | Data bus D6 inputiourne 10 | Neues leariaven B_| Data bus D7 inpuoutput 20 | Noted _ 1) Remove he tp and bottom ever 9 | Remote Control feontroling) RP inpat_| 21 | Remote Control eontraling] WP input 2} Remove the plate stached tthe rear 70 | Remote Control linterupt] SAGinput | 22 | Remote Contre eontealing! DAV Inout fanaa pas te eae dont [a1 [saves sats output Z3__| Transmision Control SEND input ial isten Sehr 32 yaev cow | 24 | Ground 1 3) Install the unit onto where it is spe tied and connert the ebles om + v0~o7 1 SOLS (Squeteh Sion the connector. Data bur that functions at bidicetionl 8 bit parallel, Ie issat at TTL lve. ‘© RP (Read Puss) Convlling data is sent fom the transeiver/ ‘ncrver fo the romate controller wen this line HH level (20V). Ie isunsally a L lve '© sR (service Request! Line shows that data is being exchanged between the tansceier/ecsver and the controller, while the data is boing exchanged, tis line is L lve (OV). Usialy, he tines H lve (454), 48 Power supply forthe controller, Maximum cur rent 100m, Terminal fora signal tat automatically stops the frequency scanning. Voltage is +8V when the suelo, and OV when itis opened (© WP (Write Puts) Controlling ta are sant from the remote con: teller to the transceiver receiver wine this fine it tH level (250). Teieuavally a Live (OV), ‘© DAV (Date Vaid) This line sow dite has been reosived, Iti valid atL level (Ov), © Seno ‘Wen this ine i grounded, the transceiver changes 4) Plug the cables from {and JB ofthe LOGIC unit 5) Repise the top and bottom coves ICOM INCORPORATED 16:19, KAMIKURATSUKURI, OSAKA JAPAN HIRANO-KU,

You might also like