PFC Dual Boost Converter Based On Input Voltage Estimation For DC Inverter Air Conditioner
PFC Dual Boost Converter Based On Input Voltage Estimation For DC Inverter Air Conditioner
JPE 10-3-10
† Dept. of Control and Instrumentation Eng., Gyeongsang National University, Jinju, Korea
∗ AC Control 2 Group, AC Control R&D Lab, LG Electronics Inc., Changwon, Korea
Abstract
In this paper, a single-phase PFC (Power Factor Correction) dual boost converter based on input voltage estimation is studied
for DC inverter air conditioner. It is focused on improving input power factor and power quality to satisfy the recent harmonic
current regulation standards. Furthermore the input voltage estimation is introduced for price competitive products. A low cost
and reasonable control system is implemented using a specified high-speed 32-bit microprocessor. Their effectiveness are verified
through theoretical analysis and experiments.
Key Words: Dual boost converter, Power factor correction, Voltage estimation, DC inverter air conditioner, Harmonic current
I. I NTRODUCTION
With the increase in use of HVAC (heating, ventilation,
and air conditioning) systems, power demands have increased
considerably. Thus global warming and various environmental
problems have been accelerating the Kyoto-Protocol intro-
duced in 1997, to prevent global warming by regulating
carbon-dioxide emissions and minimizing energy consump-
tion, has accelerated the trend for developing highly energy
efficient products.
In particular, home appliances like air conditioners, washing
machines, refrigerators, etc. are required to be eco-friendly and
highly energy-efficient. As a result, need for energy efficient
systems like inverter control system are increasing rapidly. Fig. 1. Noise comparison according to installed position of inductor.
DC inverter air conditioner (named in the products of
LG Electronics) using permanent magnet synchronous motor
Minimizing harmonics in a power conversion system increases
(IPMSM) consists of a converter, a DC-link circuit, and an
manufacturing costs. In order to minimize additional manu-
inverter.
facturing costs, the most suitable design for power conversion
Harmonic currents and power factor of power grid are
system is required.
dependent on configuration of power conversion system and
its control algorithm. Increased harmonic current and reduced By analyzing common mode noise shown in Fig. 1, it
input power factor adversely affect other electric equipments can be seen that a dual boost converter (DBC) with power
connected to power grid, thus causing these connected systems factor correction (PFC) should be optimized [1]. Furthermore
to malfunction and reducing lifetime. Therefore, many coun- problem of power quality caused by resonance of input LC
tries have introduced more forceful laws to regulate power filter should be solved [2]. These are important works to
quality. be treated and solved from power conversion system point
In the EU, electrical products can’t be marketed if they of view. To improve input power factor and suppress total
doesn’t meet the IEC 61000-3-2 harmonic current regulation harmonic distortion, circuit configuration and algorithm [4],
standards. Therefore products should adopt power conversion [5] need to be proposed. Introducing input voltage sensorless
system that satisfy the harmonic current regulation standards. algorithm, where input voltage is estimated only via input
current information, the cost cut of total system should be
Manuscript received Jan. 15, 2010; revised Apr. 6, 2010
† Corresponding Author: kimtw@gnu.ac.kr
implemented. These are important factors to be considered
Tel: +82-55-751-5373, Gyeongsang National University
for price-competitive home appliances [3], [6], [7].
∗ AC Control 2 Group, AC Control R&D Lab, LG Electronics Inc., Korea In this paper, to solve these issues, single high-speed mi-
294 Journal of Power Electronics, Vol. 10, No. 3, May 2010
croprocessor based on dual boost converter is used to control B. Harmonic current regulations
PFC, two inverters for fan and compressor. And also the dual DC inverter air conditioner is categorized as an electric
boost converter with PFC for DC inverter air conditioner is home appliance and should comply with IEC 61000-3-2 Class
implemented and tested. These possibilities have been verified A regulations. Allowable maximum harmonic currents under
through theoretical analysis and experiments. IEC 61000-3-2 Class A regulations are shown in Table 1.
Even though the power consumption is less than 600W ,
II. DC INVERTER AIR CONDITIONER the permissible 3rd harmonic current is 2.3A. Irrespective of
consumption, all equipments must comply with the standards.
A. Configuration of control system The input power factor (PF) can be expressed as the ratio
DC inverter air conditioner is called total control system of fundamental current to total input current as shown in (1).
for IPMSM drive, and the entire system is briefly presented
P Vs Vs1 cos θ Is1
as follows. PF = = = cos θ (1)
S Vs Is Is
As shown in Fig. 2, consider the case of commercial air
conditioner (CAC) unit consisting of an indoor unit and an where P : active power, Q : reactive power, S : apparent
outdoor unit. A four-core cable is used for communication and power, Vs : input voltage, Is : input current (total input
power supply between indoor and outdoor units. As previously current), Is1 : fundamental input current.
mentioned, a highly efficient air conditioner should be energy-
efficient and requires coefficient of performance (COP) 4.0 Fig. 3 shows the minimum input power factor required to
or above. To achieve high energy-efficiency, highly efficient comply with the regulations, under the given load current using
IPMSM is used as compressor motor and fan motor, and also (1) and Table 1.
the size of heat exchanger should be well matched with the To pass the environmental regulations shown in Fig. 3, the
entire system. given input power factor under full load conditions should
The indoor unit has a microprocessor based control system be satisfied. Under 7A load conditions, 95% of input power
to adjust the amount and the direction of air flows. It also has factor should be at least satisfied. Furthermore, under more
to display and receive the remote control signals. The outdoor than 16A load conditions, minimum 98% of input power factor
unit has a microprocessor based control system to adjust com- should be satisfied. Therefore the most suitable method for
pressor capacity, heat exchanger capacity, fan motor, power power factor correction should be selected to satisfy the above
factor correction, and DC-link voltage regulation. conditions.
Induction motor, synchronous reluctance motor, brushless
DC motor, and permanent magnet synchronous motor are III. P ROPOSAL OF DUAL BOOST CONVERTER WITH PFC
generally used as compressor motor, but the use of IPMSM CONTROL
has increased due to its high efficiency. With the emergence of
A. System configuration
rare-earth magnets, IPMSM in high-end consumer electronics
has been increasing thus realizing high efficiency electric The system configuration proposed in this paper is shown
appliances. in Fig. 4 and it consists of the following; EMC filter, LCL
Fig. 2 shows commercially available DC inverter air condi- filter with damping resistance to suppress resonance, converter
tioner, in which IPMSM is used as both fan motor for indoor with internal IGBT protection functions, DC-link circuit with
unit and compressor motor for outdoor unit. DC inverter air capacitor between converter and inverter, and an inverter for
conditioner has highly efficient product design. Only converter driving compressor motor and fan motor. The overall system
control among control systems of the outdoor unit is men- is controlled by a high speed microprocessor.
tioned. The conventional converter with PFC control in Fig. 5(a)
requires a power diode with ultra fast recovery time charac-
teristics, and includes safety problems and reliability issues.
Z
VM [n] = VM [n − 1] + KE · ∆is [n] cos θM [n − 1] (16)
dc = Kpc · ierr + Kic ierr dt (25)
where Kpc and Kic are proportional gain and integral gain of
θM [n] = θM [n − 1] + ωTs − Kθ ∆is [n] sin θM [n − 1] (17) input power factor correction respectively.
where KE : current gain in model equation, Kθ : current phase The overall block diagram of proposed PFC control is
gain in model equation. shown in Fig. 6. Fig. 6 shows the unity PFC controller of
PFC Dual Boost Converter Based on Input Voltage Estimation for · · · 297
Fig. 13. Input power and power factor according to operating frequency of
compressor.
Fig. 11. Experimental power analyzed data under given 4kW DC inverter PFC dual boost converter for DC inverter air conditioner.
control system; input current, input power factor, compressor phase current,
and compressor operating frequency.
The controller’s reliability and quality are verified through
experiments. The differentiated performances in this paper
are as follows.
in on PCB. Controller reliability is increased by modularizing
power components.
• Reliability improvement of electronic components
through PFC modularization to improve the reliability
V. C ONCLUSIONS of control system
In this paper, a cost-competitive 4kW DC inverter control • Elimination of voltage sensors by estimating input voltage
system for air conditioner is implemented using high-speed required for PFC control through feedbacked current
microprocessor. It also describes the design of a single-phase information.
PFC Dual Boost Converter Based on Input Voltage Estimation for · · · 299