Vernier Calibration

You might also like

Download as pdf
Download as pdf
You are on page 1of 8
Vasar Bes na ACTION meester /l////MM ERs rn ee06064026, 9039004020 (altered ae Wolo “wr actonongeet cam CALIBRATION CERTIFICATE | CERTLNO.:.ccsisi0518-19 | DATE: 07-08-2018 | PAGENO.: 1 OF 2 CUSTOMER NAME & —: AV MARINES., BARODA ADDRESS INSTRUMENT CODE bo INSTRUMENT 1 VERNIER CALIPER MAKE 2 INSIZE SR. NO. 4121112661 RANGE + 0-300.mm LEAST COUNT 0.02 mm CONDITION ON RECEIPT : VISUALLY FOUND GooD. @ receiven on + 06-08-2018 CALIBRATED ON 07-08-2018 CALIBRATION DUE ON — 05-08-2019 | CALIBRATION CARRIED OUT AT [tag [ENVIRONMENTAL CONDITIONS | TEMPERATURE 20 "0 [£0.5°C] | HUMIDITY :[ 5010] % RH | sop. No. [23 = STANDARD INSTRUMENTS USED FOR CALIBRATION TRACEABLE TO NATIONAL STANDARDS THROUGH NABL ACCREDITED LAB. [NAME OF [ SR. NO.7 TRACEABILITY CALI.DUE DATE | | INSTRUMENT IDNO. ___| REPORT NO. I SLIP GAUGE SET | 9816 | severoz06 (04-08-2020 ] @ | icansine) AEIM/O2 - STEEL CALIPER | 0985 | con74008 06-12-2018 CHECKER Azra L| | DiciTaL OUTSIDE | 2506860 CONIAEI@% 07-09-2018 | | MICRO METER AE/W/A8 L _ | Sremonis. 2. The results lated only tthe hom (3) ca ofthe proprietor of laboratory. produced exceptinfllwithoutwrtten appro 4.The suitability ofthe instrument forts required use ls tobe decided by user. CALIBRATED BY ‘AUTHORIZED SIGNATORY GM-QA & Toch. (PARESH UPADHYAYA) a MMM BRes Ph, : 6866064026, 9033064026 E-mal:ifo@actonengineers.com — Website : www.actionengineers.com CALIBRATION CERTIFICATE [ CERTI. NO. : Ces/3105/18-19 cL DATE : 07-08-2018 PAGE NO. : 20F 2 CALIBRATION RESULTS : sO 100 200 270 284 ‘Standard Length Observed Error of UC in ym [ AFTER ZERO SETTING ] External Measurement: | At Top of Jaws +20 +20 +20 : +24 e | At Centre of Jaws: +200 | +20 +20 : +2 At Bottom of Jaws, +20 +20 +20 2 Average Error +20 +20 +2 |e + | Internal Measurement: Observed Error 00 00 -20 -20 Depth Measurement: [Observed Error +60 +60 +60 : Error of UUC | Parallelism of Measuring Faces of UUC - - - in pm @ | A [aratesm of externa measuring faces a 50 mm 10 8 | Parallelism of external measuring faces at 100 mm 10 C | Parallelism of internal measuring faces at 20 mm 10 UUC : UNIT UNDER CALIBRATION EXPANDED UNCERTAINTY OF MEASUREMENT: + 23 MICRON ( AT 9.45 % CONFIDENCE LEVEL, k=2 ) NOTE : DUE TO FINE ADJUSTMENT ASSEMBLY, INSTRUMENT IS CHECKED ONLY UPTO 280 mm. 7 The results reporied here are val ony alihe ime ofand understated condiions of mescurements, 2. The results related only tothe Nam (@) calbrated. 3. This certificate shallnctbe reproduced excoptinfullwithout writen approval ofthe proprietor of laboratory. 4 The sutabilty ofthe instrument forts required use is tobe decided by User. CALIBRATED BY AUTHORIZED SIGNATORY GM-QA & Tech. (PARESH UPADHYAYA) eeemecrscses —/I///// MMM BERR Ph. 8866064026, 9033064026 nm arentariay E-mail: info@actonengineers.com ‘Website : www actionengineers:com CALIBRATION CERTIFICATE cutee C0240 [ CERTI. No. : Ccsi3103/18-19 | bate : 07-00-2010 _PAGENO.:10F2 | CUSTOMER NAME& ©: A.V. MARINES. BARODA ADDRESS INSTRUMENT CODE : INSTRUMENT : DIAL CALIPER MAKE 2 MITUTOYO: SERIES NO. 2 5605-684 SR. NO. 2 12546487 RANGE 0-200 mm LEAST COUNT 20.02 mm @ — conoirion on RECEIPT ; VISUALLY FOUND GooD RECEIVED ON + 06-08-2018 CALIBRATED ON : 07-08-2018 CALIBRATION DUE ON — : 06-08-2019 [CALIBRATION CARRIED OUT AT _| LAB _ ENVIRONMENTAL CONDITIONS __| TEMPERATURE 202°C (#0.5°C] | HUMIDITY [50210] % AH |S0P. No. [3 | STANDARD INSTRUMENTS USED FOR CALIBRATION TRACEABLE TO NATIONAL STANDARDS ‘THROUGH NABL ACCREDITED LAB. NAME OF 'SR.NO./ TRACEABILITY CALI. DUE DATE ] LINSTRUMENT | IDNO. REPORT NO. _ i 7 | | _ = @ [apcmceser [oa sa/eioa08 oa08-3025 | (CARBIDE ) ABIMO2 | STEEL CALIPER | 0985 | cor7i4006 06-12-2078 | CHECKER AE/MO3 _. al | DIGITAL OUTSIDE | 25036960 CONIAE/@1 07-03-2019 | MicRO METER AE/M/48 | 7 The reslis reported here are valid only alihe ime of and under slated condlions of measurements. 2. The results related only tote hems) ca £3.This certificate shall note reproduced excoptin fullwthout writen approval ofthe proprotor of laboratory The suitability ofthe instrument forts required use is tobe decided by user CALIBRATED BY

You might also like