Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Consequence Summary Report

Workspace: 214 F. Fan Cooler Consequence Assessment


Study: Study
Summary Basis
These tables will only report global values set in the parameters. Values that are modified in the study tree will not be
reported.
The report is context sensitive, and filters up to the study level. You willl need to generate multiple summary reports
if you have multiple studies in your workspace.
Discharge Results (after atmospheric expansion)

Path Scenari Weathe Mass Temper Liquid Droplet Expand Velocit Release
o r flow ature mass diamet ed y [m/s] duratio
rate [degC] fraction er [um] diamet n [s]
[kg/s] in er [m]
materia
l
[fractio
n]

214 F. Fan Cooler 6mm Category 0.34263 -44.9258 0 0 0.031116 1514.31 3600
Consequence 5/D 9
Assessment\Study
\214\F.F-102_1ST
STAGE HOT SEP VAP
TO CONDENSER
INLET

214 F. Fan Cooler Category 0.382463 -98.4732 0 0 0.030464 1349.23 3600


Consequence 5/D 1
Assessment\Study
\214\F.Fan 102_1ST
STAGE HOT SEP VAP
TO CONDENSER
OUTLET

214 F. Fan Cooler Category 0.29815 -44.0874 0 0 0.030940 1740.68 3600


Consequence 5/D 7
Assessment\Study
\214\F.Fan 104_2ND
STG HOT SEP VAP
FR COLD CFD LIQ
EXCH inlet

214 F. Fan Cooler Category 0.335185 -100.477 0 0 0.030280 1539.88 3600


Consequence 5/D 3
Assessment\Study
\214\F.Fan 104_2ND
STG HOT SEP VAP
FR COLD CFD LIQ
EXCH outlet

214 F. Fan Cooler Category 0.067743 67.6689 0 0 0.010114 424.76 3600

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 1 of 12
Consequence 5/D 8 6
Assessment\Study
\214\F.Fan-214-105
STRIPPER OVHD
VAPOR inlet

214 F. Fan Cooler Category 0.072923 9.53837 0 0 0.010058 379.093 3600


Consequence 5/D 3
Assessment\Study
\214\F.Fan-214-105
STRIPPER OVHD
VAPOR outlet

214 F. Fan Cooler Category 0.112106 10.1305 0 0 0.012521 396.772 3600


Consequence 5/D 9
Assessment\Study
\214
\F.Fan-214-110_DEB
UTANIZER OVHD
VAPOR INLET

214 F. Fan Cooler Category 0.113333 -3.9738 0 0 0.012475 382.515 3600


Consequence 5/D
Assessment\Study
\214
\F.Fan-214-110_DEB
UTANIZER OVHD
VAPOR OUTLET

214 F. Fan Cooler Category 0.062229 81.0327 0 0 0.014286 1402.68 3600


Consequence 5/D 8 2
Assessment\Study
\214
\F.Fan-214-101_HO
T FLASH VAPOR TO
CONDENSER INLET

214 F. Fan Cooler Category 0.079772 -77.4272 0 0 0.013727 1075.17 3600


Consequence 5/D 8 4
Assessment\Study
\214
\F.Fan-214-101_HO
T FLASH VAPOR TO
CONDENSER
OUTLET

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 2 of 12
Dispersion Results
Input dispersion parameters

Core averaging time 18.75 s

Flammable averaging time 18.75 s

Height of interest 0 m

Distance downwind to defined concentrations


The reported concentration of interest is defined at the scenario

Path Scenario Weather Distance to Distance to Distance to


UFL [m] LFL [m] LFL fraction
[m]

214 F. Fan Cooler Consequence 6mm Category 5/D n/a n/a 14.303
Assessment\Study\214
\F.F-102_1ST STAGE HOT SEP
VAP TO CONDENSER INLET

214 F. Fan Cooler Consequence Category 5/D n/a n/a 16.9678


Assessment\Study\214\F.Fan
102_1ST STAGE HOT SEP VAP TO
CONDENSER OUTLET

214 F. Fan Cooler Consequence Category 5/D n/a n/a 14.8392


Assessment\Study\214\F.Fan
104_2ND STG HOT SEP VAP FR
COLD CFD LIQ EXCH inlet

214 F. Fan Cooler Consequence Category 5/D n/a n/a 17.201


Assessment\Study\214\F.Fan
104_2ND STG HOT SEP VAP FR
COLD CFD LIQ EXCH outlet

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 3 of 12
Jet Fire Results
Distance downwind to defined radiation levels
The reported radiations are defined in the parameters

Path Scenario Weather Flame Distance Distance Distance


length [m] downwind downwind downwind
to intensity to intensity to intensity
level 1 (4 level 2 level 3
kW/m2) (12.5 kW/ (37.5 kW/
[m] m2) [m] m2) [m]

214 F. Fan Cooler 6mm Category 5/D 7.38278 2.95816 1.60893 n/a
Consequence Assessment
\Study\214\F.F-102_1ST
STAGE HOT SEP VAP TO
CONDENSER INLET

214 F. Fan Cooler Category 5/D 7.95255 3.39534 2.02307 n/a


Consequence Assessment
\Study\214\F.Fan 102_1ST
STAGE HOT SEP VAP TO
CONDENSER OUTLET

214 F. Fan Cooler Category 5/D 7.13649 2.85039 1.54105 n/a


Consequence Assessment
\Study\214\F.Fan 104_2ND
STG HOT SEP VAP FR COLD
CFD LIQ EXCH inlet

214 F. Fan Cooler Category 5/D 7.73087 3.30215 1.96304 n/a


Consequence Assessment
\Study\214\F.Fan 104_2ND
STG HOT SEP VAP FR COLD
CFD LIQ EXCH outlet

214 F. Fan Cooler Category 5/D 3.783 n/a n/a n/a


Consequence Assessment
\Study\214\F.Fan-214-105
STRIPPER OVHD VAPOR inlet

214 F. Fan Cooler Category 5/D 3.97852 n/a n/a n/a


Consequence Assessment
\Study\214\F.Fan-214-105
STRIPPER OVHD VAPOR
outlet

214 F. Fan Cooler Category 5/D 4.79103 0.852208 n/a n/a


Consequence Assessment
\Study\214
\F.Fan-214-110_DEBUTANIZ
ER OVHD VAPOR INLET

214 F. Fan Cooler Category 5/D 4.90011 0.977315 n/a n/a


Consequence Assessment
\Study\214
\F.Fan-214-110_DEBUTANIZ
ER OVHD VAPOR OUTLET

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 4 of 12
214 F. Fan Cooler Category 5/D 3.26959 n/a n/a n/a
Consequence Assessment
\Study\214
\F.Fan-214-101_HOT FLASH
VAPOR TO CONDENSER
INLET

214 F. Fan Cooler Category 5/D 3.89619 n/a n/a n/a


Consequence Assessment
\Study\214
\F.Fan-214-101_HOT FLASH
VAPOR TO CONDENSER
OUTLET

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 5 of 12
Flash Fire Results
Distance downwind to defined concentrations
The reported LFL and LFL fraction are defined in the respective material property

Path Scenario Weather Distance downwind


to LFL Fraction [m]

214 F. Fan Cooler Consequence Assessment 6mm Category 5/D 14.303


\Study\214\F.F-102_1ST STAGE HOT SEP VAP
TO CONDENSER INLET

214 F. Fan Cooler Consequence Assessment Category 5/D 16.9678


\Study\214\F.Fan 102_1ST STAGE HOT SEP VAP
TO CONDENSER OUTLET

214 F. Fan Cooler Consequence Assessment Category 5/D 14.8392


\Study\214\F.Fan 104_2ND STG HOT SEP VAP
FR COLD CFD LIQ EXCH inlet

214 F. Fan Cooler Consequence Assessment Category 5/D 17.201


\Study\214\F.Fan 104_2ND STG HOT SEP VAP
FR COLD CFD LIQ EXCH outlet

214 F. Fan Cooler Consequence Assessment Category 5/D


\Study\214\F.Fan-214-105 STRIPPER OVHD
VAPOR inlet

214 F. Fan Cooler Consequence Assessment Category 5/D


\Study\214\F.Fan-214-105 STRIPPER OVHD
VAPOR outlet

214 F. Fan Cooler Consequence Assessment Category 5/D


\Study\214\F.Fan-214-110_DEBUTANIZER OVHD
VAPOR INLET

214 F. Fan Cooler Consequence Assessment Category 5/D


\Study\214\F.Fan-214-110_DEBUTANIZER OVHD
VAPOR OUTLET

214 F. Fan Cooler Consequence Assessment Category 5/D


\Study\214\F.Fan-214-101_HOT FLASH VAPOR
TO CONDENSER INLET

214 F. Fan Cooler Consequence Assessment Category 5/D


\Study\214\F.Fan-214-101_HOT FLASH VAPOR
TO CONDENSER OUTLET

Maximum distance to LFL fraction at any height

Path Scenario Weather Max flash Height of the Time [s]


fire distance max flash
[m] fire distance
[m]

214 F. Fan Cooler Consequence 6mm Category 5/D 22.6772 1.68231 23.8503

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 6 of 12
Assessment\Study\214
\F.F-102_1ST STAGE HOT SEP
VAP TO CONDENSER INLET

214 F. Fan Cooler Consequence Category 5/D 25.9994 1.7557 71.524


Assessment\Study\214\F.Fan
102_1ST STAGE HOT SEP VAP TO
CONDENSER OUTLET

214 F. Fan Cooler Consequence Category 5/D 23.0562 1.86555 7.51581


Assessment\Study\214\F.Fan
104_2ND STG HOT SEP VAP FR
COLD CFD LIQ EXCH inlet

214 F. Fan Cooler Consequence Category 5/D 26.1662 1.95816 7.5161


Assessment\Study\214\F.Fan
104_2ND STG HOT SEP VAP FR
COLD CFD LIQ EXCH outlet

214 F. Fan Cooler Consequence Category 5/D 4.09602 0.979825 7.51447


Assessment\Study\214
\F.Fan-214-105 STRIPPER OVHD
VAPOR inlet

214 F. Fan Cooler Consequence Category 5/D 4.30532 0.962151 7.51449


Assessment\Study\214
\F.Fan-214-105 STRIPPER OVHD
VAPOR outlet

214 F. Fan Cooler Consequence Category 5/D 5.10164 0.985095 23.8451


Assessment\Study\214
\F.Fan-214-110_DEBUTANIZER
OVHD VAPOR INLET

214 F. Fan Cooler Consequence Category 5/D 5.13652 0.980051 23.8451


Assessment\Study\214
\F.Fan-214-110_DEBUTANIZER
OVHD VAPOR OUTLET

214 F. Fan Cooler Consequence Category 5/D 5.80037 1.04873 7.51453


Assessment\Study\214
\F.Fan-214-101_HOT FLASH
VAPOR TO CONDENSER INLET

214 F. Fan Cooler Consequence Category 5/D 6.83485 1.04425 23.8456


Assessment\Study\214
\F.Fan-214-101_HOT FLASH
VAPOR TO CONDENSER OUTLET

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 7 of 12
Explosion Results
Explosion scenarios for worst-case maximum downwind distance to defined overpressures.
These results are produced during the consequence run and depend on the precise setting of the
scenario. These results may be quite different to the explosion results calculated during the risk or effects
modelling as these will depend on the obstructed regions defined on the map.
The reported overpressures are defined in the explosion parameters

Path Scenario Weather Overpressure Maximum Diameter


level [bar] distance [m] [m]

214 F. Fan Cooler Consequence 6mm Category 5/D 0.02068 45.5395 51.079
Assessment\Study\214 0.1379 24.9638 9.92755
\F.F-102_1ST STAGE HOT SEP 0.2068 23.7216 7.4433
VAP TO CONDENSER INLET

214 F. Fan Cooler Consequence 0.02068 48.3369 56.6738


Assessment\Study\214\F.Fan 0.1379 25.5075 11.0149
102_1ST STAGE HOT SEP VAP TO 0.2068 24.1293 8.25858
CONDENSER OUTLET

214 F. Fan Cooler Consequence 0.02068 47.2128 54.4256


Assessment\Study\214\F.Fan 0.1379 25.289 10.578
104_2ND STG HOT SEP VAP FR 0.2068 23.9655 7.93096
COLD CFD LIQ EXCH inlet

214 F. Fan Cooler Consequence 0.02068 50.3029 60.6058


Assessment\Study\214\F.Fan 0.1379 25.8896 11.7792
104_2ND STG HOT SEP VAP FR 0.2068 24.4158 8.83156
COLD CFD LIQ EXCH outlet

Supplementary data for worst-case explosion scenarios

Path Scenari Weathe Overpr Total Explosi Ignitio Ignitio Cloud Explosi
o r essure flamma on n time n centre on
level ble flamma [s] source [m] centre
[bar] mass ble [m] [m]
[kg] mass
[kg]

214 F. Fan Cooler 6mm Category 0.02068 0.13859 n/a 5.50001 20 5.45063 20
Consequence 5/D 0.1379 0.13859 n/a 5.50001 20 5.45063 20
Assessment\Study 0.2068 0.13859 n/a 5.50001 20 5.45063 20
\214\F.F-102_1ST
STAGE HOT SEP VAP
TO CONDENSER
INLET

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 8 of 12
214 F. Fan Cooler 0.02068 0.1893 n/a 4.32514 20 6.11073 20
Consequence 0.1379 0.1893 n/a 4.32514 20 6.11073 20
Assessment\Study 0.2068 0.1893 n/a 4.32514 20 6.11073 20
\214\F.Fan 102_1ST
STAGE HOT SEP VAP
TO CONDENSER
OUTLET

214 F. Fan Cooler 0.02068 0.141569 n/a 5.29763 20 5.90301 20


Consequence 0.1379 0.141569 n/a 5.29763 20 5.90301 20
Assessment\Study 0.2068 0.141569 n/a 5.29763 20 5.90301 20
\214\F.Fan 104_2ND
STG HOT SEP VAP
FR COLD CFD LIQ
EXCH inlet

214 F. Fan Cooler 0.02068 0.19548 n/a 4.25071 20 6.60988 20


Consequence 0.1379 0.19548 n/a 4.25071 20 6.60988 20
Assessment\Study 0.2068 0.19548 n/a 4.25071 20 6.60988 20
\214\F.Fan 104_2ND
STG HOT SEP VAP
FR COLD CFD LIQ
EXCH outlet

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 9 of 12
Outdoor Toxic Results
Distance downwind to defined concentrations
The reported concentrations are defined in the respective material properties

Path Scenario Weather Distance Distance Distance Distance Distance


downwin downwin downwin downwin downwin
d to d to d to d to STEL d to IDLH
ERPG1 ERPG2 ERPG3 (900 s) (1800 s)
(3600 s) (3600 s) (3600 s) [m] [m]
[m] [m] [m]

214 F. Fan Cooler 6mm Category 5/ n/a n/a n/a n/a n/a
Consequence Assessment D
\Study\214\F.F-102_1ST
STAGE HOT SEP VAP TO
CONDENSER INLET

214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a


Consequence Assessment D
\Study\214\F.Fan
102_1ST STAGE HOT SEP
VAP TO CONDENSER
OUTLET

214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a


Consequence Assessment D
\Study\214
\F.Fan-214-105 STRIPPER
OVHD VAPOR inlet

214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a


Consequence Assessment D
\Study\214
\F.Fan-214-105 STRIPPER
OVHD VAPOR outlet

214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a


Consequence Assessment D
\Study\214
\F.Fan-214-110_DEBUTA
NIZER OVHD VAPOR
INLET

214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a


Consequence Assessment D
\Study\214
\F.Fan-214-110_DEBUTA
NIZER OVHD VAPOR
OUTLET

214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a


Consequence Assessment D
\Study\214
\F.Fan-214-101_HOT
FLASH VAPOR TO
CONDENSER INLET

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 10 of 12
214 F. Fan Cooler Category 5/ n/a n/a n/a n/a n/a
Consequence Assessment D
\Study\214
\F.Fan-214-101_HOT
FLASH VAPOR TO
CONDENSER OUTLET

Distance downwind to defined dangerous doses


The reported dangerous doses are defined in the respective material properties
Exposure duration at defined dangerous doses
The reported dangerous doses are defined in the respective material properties

Audit Number: 7978


Date: 04/03/2019 Time: 6:48 PM
Page 11 of 12
Audit Number: 7978
Date: 04/03/2019 Time: 6:48 PM
Page 12 of 12

You might also like