Professional Documents
Culture Documents
Proposed Plan As Per Budget: C.R. C.R
Proposed Plan As Per Budget: C.R. C.R
Proposed Plan As Per Budget: C.R. C.R
2.OO M
JALOUSIE WINDOW: JALOUSIE WINDOW:
SINGLE CONTROL SINGLE CONTROL
14 87" 4 BLADES 14 87" 4 BLADES
(ANALOK) (ANALOK)
7OOmm X 21OOmm 7OOmm X 21OOmm
ROOF LINE EXIT DOOR EXIT DOOR ROOF LINE
(ANALOK) (ANALOK)
C.R. C.R.
6OOmm X 21OOmm 6OOmm X 21OOmm
PVC DOOR PVC DOOR
9.OO M
1.OO M
3.2O M
JALOUSIE WINDOW:
DOUBLE CONTROL
7
35 8" 1O BLADES
(ANALOK)
ENTRY ENTRY
JALOUSIE WINDOW: JALOUSIE WINDOW: JALOUSIE WINDOW: JALOUSIE WINDOW:
1.5O M
ROOF LINE DOUBLE CONTROL DOUBLE CONTROL DOUBLE CONTROL ROOF LINE DOUBLE CONTROL
35 87 " 1O BLADES 35 87 " 1O BLADES 35 87 " 1O BLADES 35 87 " 1O BLADES
(ANALOK) (ANALOK) (ANALOK) (ANALOK)
1.15 M 1.15 M
4.025 M 4.OO M
WALL FOOTING
WALL FOOTING
WALL FOOTING
@15Omm
THICKNESS ;
@2OOmm WALL FOOTING WALL FOOTING
WALL FOOTING
WALL FOOTING
1Omm Ø
DEFORMED BARS
@ 5OOmm O.C.
WALL FOOTING WALL FOOTING
BOTHWAYS WALL FOOTING
WALL FOOTING
5.3O M
1OO mm THICK
CONCRETE FLOOR
WALL FOOTING
WALL FOOTING
4.025 M 4.OO M
FOUNDATION PLAN
O.8O M
O.2O M O.15 M
COLUMN FOOTING
DETAILS
PROPERTY LINE PROPERTY LINE
C-PURLIN (2X3X1.5)
O.6 M
O.6 M
O.6 M
ANGLE BAR
121 X 121 X 3
O.6 M
O.6 M
TRUSS
TRUSS
TRUSS
O.6 M
O.6 M
O.6 M
PREFAB SPANISH
O.6 M
GUTTER GUTTER
ROOF LINE
O.888 M
0.6 M
C-PURLIN 2X3X1.5
PREFAB SPANISH
GUTTER (PLAIN SHEET)
6.OO M
2" PVC DOWNSPOUT
TRUSS DETAILS
PROPERTY LINE PROPERTY LINE
S1 S1
S1 S1
S2 S2
LEGEND:
PANEL BOARD
CONVENIENCE OUTLET
LIGHTING OUTLET
S2 S2
S1 SINGLE GANG FLUSH TYPE SWITCH
ELECTRICAL LAYOUT
PROPERTY LINE PROPERTY LINE
OVERHANG
O.8 M
METAL FURRING
2 X 43 X 0.5 X 5
HARDIFLEX
6.1O M
3
16" THCK
0.2O M
SEPTIC TANK
SEPTIC TANK
F.D. F.D.
F.D. F.D.
F.D. F.D.
TO SEWER LINE
TO SEWER LINE
ROOF LINE CATCH CATCH ROOF LINE
BASIN BASIN
SANITARY LAYOUT
1.8O M
1.OO M O.8O M
0.3O M O.3O M
O.3O M
1.OO M
O.3O M
1.OO M
0.3O M O.3O M
1.OO M O.8O M
1.8O M
1.8O M
1.OO M O.8O M
1.8O M O.3O M
C.O.
O.3O M
C.O.
0.3O M O.3O M
3" Ø PVC
INLET PIPE
3" Ø PVC
OUTLET PIPE
1.8O M
1.OO M
O.3O M
LEACHING DIGESTIVE
CHAMBER CHAMBER
O.5O M
CATCH BASIN DETAILS O.5O M
O.4O M
O.5O M
ROOF LINE
CEILING LINE
EL=+25OO
EL=O
INLET PIPE
3" Ø PVC
OUTLET PIPE
SIDE SECTION-ELEVATION
FIREWALL HEIGHT
EL=+42OO
ROOF APEX
EL=+3891
CEILING LINE
EL=+25OO
NGL
EL=O
15Omm
2OOmm
FRONT SECTION
FIREWALL HEIGHT
EL=+42OO
ROOF APEX
EL=+3891
CEILING LINE
EL=+25OO
FFL
EL=+2OO
NGL
EL=O
FRONT ELEVATION
FIREWALL HEIGHT
EL=+42OO
ROOF APEX
EL=+3891
CEILING LINE
EL=+25OO
JALOUSIE WINDOW:
JALOUSIE WINDOW:
DOUBLE CONTROL
DOUBLE CONTROL
35 87 " 1O BLADES
35 87 " 1O BLADES
(ANALOK)
(ANALOK)
FFL
EL=+2OO
NGL
EL=O
REAR ELEVATION
FIREWALL HEIGHT
EL=+42OO
ROOF APEX
EL=+3891
CEILING LINE
EL=+25OO
JALOUSIE WINDOW:
DOUBLE CONTROL
35 87 " 1O BLADES
(ANALOK)
FFL
EL=+2OO
NGL
EL=O
LEFT-SIDE ELEVATION
(CORNER LOT)
PROPERTY LINE PROPERTY LINE
2.OO M
JALOUSIE WINDOW: JALOUSIE WINDOW:
SINGLE CONTROL SINGLE CONTROL
14 87" 4 BLADES 14 87" 4 BLADES
(ANALOK) (ANALOK)
7OOmm X 21OOmm 7OOmm X 21OOmm
ROOF LINE EXIT DOOR EXIT DOOR ROOF LINE
3.3O M
COVERED WITH COVERED WITH
HARDIFLEX HARDIFLEX
6OOmm X 21OOmm 6OOmm X 21OOmm
PVC DOOR PVC DOOR
7OOmm X 21OOmm 7OOmm X 21OOmm
9.OO M
1.OO M
CLOSET CLOSET
TV AREA TV AREA
3.2O M
ENTRY ENTRY
ROOF LINE DOUBLE CONTROL DOUBLE CONTROL DOUBLE CONTROL ROOF LINE
DOUBLE CONTROL
35 87 " 1O BLADES 35 87 " 1O BLADES 35 87 " 1O BLADES 35 87 " 1O BLADES
(ANALOK) (ANALOK) (ANALOK) (ANALOK)
1.15 M 1.15 M
PROPOSED PLAN
WITH BEDROOM VISUALIZATION