Professional Documents
Culture Documents
Inbound1333061949 PDF
Inbound1333061949 PDF
24.
There are several reasons why soil stacks are not
allowed in columns. Which is NOT the reason?
a. Pipes will interfere with reinforcing Bars
b. The size of the columns will be larger
c. Cracks and leaks cannot be detected
d. The Gas emitted will deteriorate concrete
24.
There are several reasons why soil stacks are not
allowed in columns. Which is NOT the reason?
a. Pipes will interfere with reinforcing Bars
b. The size of the columns will be larger
c. Cracks and leaks cannot be detected
d. The Gas emitted will deteriorate concrete
25.
The pipe from the public water main or source of water
supply to the building served.
a. service pipe
b. main service pipe
c. distribution pipe
d. water riser
25.
The pipe from the public water main or source of water
supply to the building served.
a. service pipe
b. main service pipe
c. distribution pipe
d. water riser
26.
The other physical properties of water is ability to climb
up a surface against the pull of gravity.
a. surface tension
b. heat absorption
c. capillarity
d. dissolving ability
26.
The other physical properties of water is ability to climb
up a surface against the pull of gravity.
a. surface tension
b. heat absorption
c. capillarity
d. dissolving ability
27.
The ability to stick itself together and pull itself together
a. surface tension
b. heat absorption
c. capillarity
d. dissolving ability
27.
The ability to stick itself together and pull itself together
a. surface tension
b. heat absorption
c. capillarity
d. dissolving ability
28.
It is less aesthetic than aeration but more certain
oxidation process. It is used commonly in cooling tower
treatment.
a. coagulation
b. ozonation
c. sedimentation
d. aeration
28.
It is less aesthetic than aeration but more certain
oxidation process. It is used commonly in cooling tower
treatment.
a. coagulation
b. ozonation
c. sedimentation
d. aeration
29.
Requires more elaborate equipment depending on the
geology of the site. Used for drilling oil and can reach up
to 1000 meters in depth.
a. bore wells
b. drilled wells
c. shore wells
d. dug wells
29.
Requires more elaborate equipment depending on the
geology of the site. Used for drilling oil and can reach up
to 1000 meters in depth.
a. bore wells
b. drilled wells
c. shore wells
d. dug wells
30.
Refers to the public water system laid underground
along the streets where the house service is connected.
a. main service
b. water source
c. water main
30.
Refers to the public water system laid underground
along the streets where the house service is connected.
a. main service
b. water source
c. water main
31.
Used to measure the kinetic energy created by the
pump.
a. pump head
b. pump load
c. NPSHa
d. NPSHr
31.
Used to measure the kinetic energy created by the
pump.
a. pump head
b. pump load
c. NPSHa
d. NPSHr
32.
Generate high rotational velocities then convert the
resulting kinetic energy of the liquid to pressure energy.
a. centrifugal pump
b. reciprocating pump
c. turbine pump
d. submersible pump
32.
Generate high rotational velocities then convert the
resulting kinetic energy of the liquid to pressure energy.
a. centrifugal pump
b. reciprocating pump
c. turbine pump
d. submersible pump
33.
It produces high head, low flow rate and suitable for
high viscosity application.
a. positive displacement
b. dynamic
c. reciprocating pump
d. piston pump
33.
It produces high head, low flow rate and suitable for
high viscosity application.
a. positive displacement
b. dynamic
c. reciprocating pump
d. piston pump
34.
It increase in energy converted to a gain in pressure
energy when the liquid is allowed to pass through an
increase area.
a. positive displacement
b. dynamic
c. reciprocating pump
d. piston pump
34.
It increase in energy converted to a gain in pressure
energy when the liquid is allowed to pass through an
increase area.
a. positive displacement
b. dynamic
c. reciprocating pump
d. piston pump
35.
Physical process in which the sediment particles collide
with each other and stick together.
a. coagulation
b. flocculation
c. sedimentation
d. aeration
35.
Physical process in which the sediment particles collide
with each other and stick together.
a. coagulation
b. flocculation
c. sedimentation
d. aeration
36.
________is a device used to move fluids, such as liquids
or slurries. A mechanical equipment displaces a volume
by physical or mechanical action.
a. pump
b. motor
c. propeller
d. machine
36.
________is a device used to move fluids, such as liquids
or slurries. A mechanical equipment displaces a volume
by physical or mechanical action.
a. pump
b. motor
c. propeller
d. machine
37.
One end is 0.30M and the other end is 0.90M long. This
prevents the pipe from snapping (breaking?) when the
soil settles. [U-shaped?]
a. gooseneck
b. corporation cock
c. ball cock
d. long neck
37.
One end is 0.30M and the other end is 0.90M long. This
prevents the pipe from snapping (breaking?) when the
soil settles. [U-shaped?]
a. gooseneck
b. corporation cock
c. ball cock
d. long neck
38.
NAMPAP means?
a. National Masteral Plumbing Association of the
Philippines
b. National Master Plumbers Associations of the
Philippines
c. National Master Plumbing Associate of the Philippines
d. none of the above
38.
NAMPAP means?
a. National Masteral Plumbing Association of the
Philippines
b. National Master Plumbers Associations of the
Philippines
c. National Master Plumbing Associate of the Philippines
d. none of the above
39.
Method of introducing a controlled amount of chlorine
to the water in order to attain a desired degree of
disinfection.
a. chlorination
b. flocculation
c. filtration
d. sedimentation
39.
Method of introducing a controlled amount of chlorine
to the water in order to attain a desired degree of
disinfection.
a. chlorination
b. flocculation
c. filtration
d. sedimentation
40.
The volume of a liquid passing through a cross section of
a stream in unit time is called?
a. steady flow
b. uniform flow
c. continuous flow
d. discharge
40.
The volume of a liquid passing through a cross section of
a stream in unit time is called?
a. steady flow
b. uniform flow
c. continuous flow
d. discharge
41.
Instrument used to measure the water flow.
a. venturi meter
b. pressure gauge
c. dynamometer
d. pitot tube
41.
Instrument used to measure the water flow.
a. venturi meter
b. pressure gauge
c. dynamometer
d. pitot tube
42.
Pour index horsepower is how many foot lbs per
minutes.
a. 30,000
b. 33,000
c. 33,333
d. 30,333
42.
Pour index horsepower is how many foot lbs per
minutes.
a. 30,000
b. 33,000
c. 33,333
d. 30,333
43.
Is the art and technique of installing pipes, fixtures and
other apparatuses in buildings & bringing the supply
liquids substances &/or ingredients and removing them
a. source distribution
b. plumbing
c. mechanics
d. none of the above
43.
Is the art and technique of installing pipes, fixtures and
other apparatuses in buildings & bringing the supply
liquids substances &/or ingredients and removing them
a. source distribution
b. plumbing
c. mechanics
d. none of the above
44.
Is plumbing system which carries water from the water
source, street main or a pump to the building and to the
various points in the building at which water is used
a. Sewage System
b. Water Supply and Distribution System
c. Drainage System
d. None of the above
44.
Is plumbing system which carries water from the water
source, street main or a pump to the building and to the
various points in the building at which water is used
a. Sewage System
b. Water Supply and Distribution System
c. Drainage System
d. None of the above
45.
Vitrified clay pipes when used as building drain or sewer
should be __ below finish ground level.
a. 0.2 m
b. 0.3 m
c. 0.5 m
d. 0.6 m
45.
Vitrified clay pipes when used as building drain or sewer
should be __ below finish ground level.
a. 0.2 m
b. 0.3 m
c. 0.5 m
d. 0.6 m
46.
Water is not affected by peak load hours and time
needed to replace broken parts does not affect water
supply.
a. Overhead feed / gravity system
b. upfeed system
c. air pressure system
d. indirect system
46.
Water is not affected by peak load hours and time
needed to replace broken parts does not affect water
supply.
a. Overhead feed / gravity system
b. upfeed system
c. air pressure system
d. indirect system
47.
Disadvantages of overfeed or gravity system, except:
a. Water is subject to contamination.
b. High maintenance cost.
c. Requires stronger foundation and other structure to
carry additional load of tank & water.
d. water supply is affected by loss of pressure inside the
tank in case of power interruption
47.
Disadvantages of overfeed or gravity system, except:
a. Water is subject to contamination.
b. High maintenance cost.
c. Requires stronger foundation and other structure to
carry additional load of tank & water.
d. water supply is affected by loss of pressure inside the
tank in case of power interruption
48.
What is the main advantages of direct or upfeed in cold
water distribution system?
a. eliminate cost of pumps and tanks.
b. sanitary due to airtight water chamber.
c. having compact pumping unit and adaptable air
pressure.
d. it is not affected by power interruptions
48.
What is the main advantages of direct or upfeed in cold
water distribution system?
a. eliminate cost of pumps and tanks.
b. sanitary due to airtight water chamber.
c. having compact pumping unit and adaptable air
pressure.
d. it is not affected by power interruptions.
49.
The retention period or the time for which suspended
matters in septic tank would settle and stabilize is:
a. 12 hours
b. 24 hours
c. 36 hours
d. 72 hours
49.
The retention period or the time for which suspended
matters in septic tank would settle and stabilize is:
a. 12 hours
b. 24 hours
c. 36 hours
d. 72 hours
50.
It is a tank that makes life easier for the well or booster
pump by preventing rapid and unnecessary pump motor
cycling.
a. pressure tank
b. gravity tank
c. overhead tank
d. cistern
50.
It is a tank that makes life easier for the well or booster
pump by preventing rapid and unnecessary pump motor
cycling.
a. pressure tank
b. gravity tank
c. overhead tank
d. cistern
51.
It is a valve that use a rubber gasket to shut off water
flow and must be installed in the correct direction to
work properly.
a. Stop valve
b. Safety valve
c. Angle valve
d. ball valve
51.
It is a valve that use a rubber gasket to shut off water
flow and must be installed in the correct direction to
work properly.
a. Stop valve
b. Safety valve
c. Angle valve
d. ball valve
52.
This is water that has first been turned into steam so
that all of its impurities are left behind. Then through
condensation, it is turned back into pure water.
a. distilled water
b. de-ionized water
c. reverse osmosis
d. purified water
52.
This is water that has first been turned into steam so
that all of its impurities are left behind. Then through
condensation, it is turned back into pure water.
a. distilled water
b. de-ionized water
c. reverse osmosis
d. purified water
53.
A process of exchanging “hard” ions for “soft”. Water
leaving the sodium-cation exchanger has little hardness,
it contains sodium salts.
a. distilled water
b. de-ionized water
c. reverse osmosis
d. purified water
53.
A process of exchanging “hard” ions for “soft”. Water
leaving the sodium-cation exchanger has little hardness,
it contains sodium salts.
a. distilled water
b. de-ionized water
c. reverse osmosis
d. purified water
54.
This is a system of water purification which allows pre-
filtered water to be forced through a semi-permeable
membrane to separate impurities from our drinking
water.
a. reverse osmosis
b. distilled water
c. de-ionized water
d. purified water
54.
This is a system of water purification which allows pre-
filtered water to be forced through a semi-permeable
membrane to separate impurities from our drinking
water.
a. reverse osmosis
b. distilled water
c. de-ionized water
d. purified water
55.
It may contain many trace minerals and chemicals,
viruses and bacteria and may be classified as water
which is harder than distilled water.
a. hard water
b. soft water
c. black water
d. grey water
55.
It may contain many trace minerals and chemicals,
viruses and bacteria and may be classified as water
which is harder than distilled water.
a. hard water
b. soft water
c. black water
d. grey water
56.
A kind of water that has not been boiled and may be
hard (as calcium hardened water) or soft as rain water.
a. soft water
b. boiled water
c. hard water
d. raw water
56.
A kind of water that has not been boiled and may be
hard (as calcium hardened water) or soft as rain water.
a. soft water
b. boiled water
c. hard water
d. raw water
57.
These are advantages of vacuum system versus gravity
system, except:
a. low installation cost
b. environmentally safe.
c. no possibility of vermin in pipelines.
d. low maintenance required
57.
These are advantages of vacuum system versus gravity
system, except:
a. low installation cost
b. environmentally safe.
c. no possibility of vermin in pipelines.
d. low maintenance required
58.
These are disadvantages of vacuum system versus
gravity system, except:
a. high component cost
b. mechanical components – possibility of failure
c. regular maintenance required
d. always self-cleansing.
58.
These are disadvantages of vacuum system versus
gravity system, except:
a. high component cost
b. mechanical components – possibility of failure
c. regular maintenance required
d. always self-cleansing.
59.
Applicable joint connection for asbestos cement pipe.
a. solvent cement
b. mechanical joint
c. soldered joint
d. threaded joint
59.
Applicable joint connection for asbestos cement pipe.
a. solvent cement
b. mechanical joint
c. soldered joint
d. threaded joint
60.
PE and PB pipes shall not be threaded.
a. true
b. false
c. may be
d. nota
60.
PE and PB pipes shall not be threaded.
a. true
b. false
c. may be
d. nota
61.
Applicable joints connection of cPVC, except:
a. mechanical joints
b. solvent cement
c. threaded joints
d. heat fusion joints
61.
Applicable joints connection of cPVC, except:
a. mechanical joints
b. solvent cement
c. threaded joints
d. heat fusion joints
62.
What is the main reason why globe valve is suitable for
throttling services?
a. ball and gate valves tend to vibrate under flow, and
erosion is a concern when using gate valves.
b. it normally operates faster.
c. more cheap than other valves.
c. it controls the full flow of the system.
62.
What is the main reason why globe valve is suitable for
throttling services?
a. ball and gate valves tend to vibrate under flow, and
erosion is a concern when using gate valves.
b. it normally operates faster.
c. more cheap than other valves.
c. it controls the full flow of the system.
63.
A valve usually used in high temperature services.
a. ball valve
b. gate valve
c. angle valve
d. plug valve
63.
A valve usually used in high temperature services.
a. ball valve
b. gate valve
c. angle valve
d. plug valve
64.
A valve usually used in high pressure services.
a. globe valve
b. gate valve
c. angle valve
d. pinch valve
64.
A valve usually used in high pressure services.
a. globe valve
b. gate valve
c. angle valve
d. pinch valve
65.
In water piping, female PVC screwed fittings shall be
used with?
a. plastic male thread
b. plastic male coupling
c. plastic male adaptor
d. union
65.
In water piping, female PVC screwed fittings shall be
used with?
a. plastic male thread
b. plastic male coupling
c. plastic male adaptor
d. union
66.
Which of the following locations DO not require
installation of a clean out?
a. At every branch interval of a soil stack
b. Any horizontal waste or soil pipe exceeding 15 meters
c. Any change in direction of a soil branch 22.5 degrees
and over.
d. At every end of every soil branch
66.
Which of the following locations DO not require
installation of a clean out?
a. At every branch interval of a soil stack
b. Any horizontal waste or soil pipe exceeding 15 meters
c. Any change in direction of a soil branch 22.5 degrees
and over.
d. At every end of every soil branch
67.
It is the process of removing residual chlorine form
disinfected wastewater prior to discharge into the
environment.
a. super-chlorination
b. dechlorination
c. prechlorination
d. chlorination
67.
It is the process of removing residual chlorine form
disinfected wastewater prior to discharge into the
environment.
a. super-chlorination
b. dechlorination
c. prechlorination
d. chlorination
68.
Which criterion is NOT needed in sizing a vent pipe for
individual, branch and circuit vent based on the total
linear footage of the pipe making up the vent?
a. Developed length of the vent pipe
b. Number of fixture unit
c. Slope of the drain pipe
d. Size of the drain pipe
68.
Which criterion is NOT needed in sizing a vent pipe for
individual, branch and circuit vent based on the total
linear footage of the pipe making up the vent?
a. Developed length of the vent pipe
b. Number of fixture unit
c. Slope of the drain pipe
d. Size of the drain pipe
69.
Where are dampers installed to regulate the amount of
cool air for an even distribution to outlets?
a. at the trunk ducts
b. at a practical location at angles and elbows
c. at the branch supply duct as far as practical from the
outlet
d. at the air boot fitting
69.
Where are dampers installed to regulate the amount of
cool air for an even distribution to outlets?
a. at the trunk ducts
b. at a practical location at angles and elbows
c. at the branch supply duct as far as practical from the
outlet
d. at the air boot fitting
70.
What is the size of supply valve for tank type water
closet?
a. 3/4”
b. 1/2”
c. 3/8”
d. 1”
70.
What is the size of supply valve for tank type water
closet?
a. 3/4”
b. 1/2”
c. 3/8”
d. 1”
71.
What is the minimum size of a trap or branch of a
residential kitchen?
a. 1 1/2”
b. 1 3/4”
c. 1 1/4”
d. 2”
71.
What is the minimum size of a trap or branch of a
residential kitchen?
a. 1 1/2”
b. 1 3/4”
c. 1 1/4”
d. 2”
72.
What is the minimum size of a trap or branch for a
lavatory?
a. 1 1/4”
b. 1 3/4”
c.. 1 1/2”
d. 2”
72.
What is the minimum size of a trap or branch for a
lavatory?
a. 1 1/4”
b. 1 3/4”
c.. 1 1/2”
d. 2”
73.
What is a type of vent applied on installations with
multi-branch interval where the vertical vent pipe takes
off in front of the first highest fixture and connects to a
main vent stack?
a. Relief vent
b. Yoke vent
c. Loop vent
d. Circuit vent
73.
What is a type of vent applied on installations with
multi-branch interval where the vertical vent pipe takes
off in front of the first highest fixture and connects to a
main vent stack?
a. Relief vent
b. Yoke vent
c. Loop vent
d. Circuit vent
74.
A tank constructed to special standards to withstand
pressure and usually coated inside with corrosion
resistant treatment as the water makes direct contact
with the interior. The air is compressed above the water.
a. air cushion tank
b. Elastic sock pressure vessel
c. Gravity tank
d. air cushion cylinder
74.
A tank constructed to special standards to withstand
pressure and usually coated inside with corrosion
resistant treatment as the water makes direct contact
with the interior. The air is compressed above the water.
a. air cushion tank
b. Elastic sock pressure vessel
c. Gravity tank
d. air cushion cylinder
75.
A kind of pressure vessels used in the hydro-pneumatic
pressure system which water is totally confined in an
elastic rubber bag. When water is pump the bag
expands, compressing the air in the cylinder until the
pressure switch reaches its setting & shuts off the
motor.
a. separated air cushion cylinder
b. air cushion tank
c. elastic sock pressure vessel
d. pressure tank
75.
A kind of pressure vessels used in the hydro-pneumatic
pressure system which water is totally confined in an
elastic rubber bag. When water is pump the bag
expands, compressing the air in the cylinder until the
pressure switch reaches its setting & shuts off the
motor.
a. separated air cushion cylinder
b. air cushion tank
c. elastic sock pressure vessel
d. pressure tank
76.
When installing ejector pump, in what order is it
installed?
a. pump, ball valve, check valve
b. ball valve, pump, check valve
c. Check valve, pump, ball valve
d. pump, check valve, ball valve
76.
When installing ejector pump, in what order is it
installed?
a. pump, ball valve, check valve
b. ball valve, pump, check valve
c. Check valve, pump, ball valve
d. pump, check valve, ball valve
77.
What is the minimum distance between a tub spout and
the flood level rim level of a bath tub?
a. 6”
b. 7”
c. 6 ½”
d. 5”
77.
What is the minimum distance between a tub spout and
the flood level rim level of a bath tub?
a. 6”
b. 7”
c. 6 ½”
d. 5”
78.
What temperature does a shower valve to be set at?
a. 85⁰F
b. 120⁰F
c. 115⁰F
d. 100⁰F
78.
What temperature does a shower valve to be set at?
a. 85⁰F
b. 120⁰F
c. 115⁰F
d. 100⁰F
79.
What is the maximum distance away from a water
heater you can install a shut off valve?
a. 1.2 m
b. 1.5 m
c. 1.8 m
d. 0.9 m
79.
What is the maximum distance away from a water
heater you can install a shut off valve?
a. 1.2 m
b. 1.5 m
c. 1.8 m
d. 0.9 m
80.
The standard size of an outlet of a dry standpipe located
for each floor is ___mm. diameter.
a. 51 mm (2”)
b. 76 mm (3”)
c. 38 mm (1 1/2”)
d. 64 mm (2 1/2”)
80.
The standard size of an outlet of a dry standpipe located
for each floor is ___mm. diameter.
a. 51 mm (2”)
b. 76 mm (3”)
c. 38 mm (1 1/2”)
d. 64 mm (2 1/2”)
81.
What is the maximum DFU’s are allowed on a 2”
horizontal drain line?
a. 6
b. 9
c. 12
d. 2
81.
What is the maximum DFU’s are allowed on a 2”
horizontal drain line?
a. 6
b. 9
c. 12
d. 2
82.
What is the maximum DFU’s are allowed on a 3”
horizontal drain line?
a. 15
b. 20
c. 22
d. 30
82.
What is the maximum DFU’s are allowed on a 3”
horizontal drain line?
a. 15
b. 20
c. 22
d. 30
83.
What is the maximum DFU’s are allowed on a 4”
horizontal drain line?
a. 160
b. 100
c. 125
d. 150
83.
What is the maximum DFU’s are allowed on a 4”
horizontal drain line?
a. 160
b. 100
c. 125
d. 150
84.
The location of a fire hose cabinet connected to a
standpipe for buildings shall be at every floor level
above the first floor at:
a. at any private room or rentable space
b. storeroom
c. inside a mechanical/electrical room
d. a landing of an enclosed stairway
84.
The location of a fire hose cabinet connected to a
standpipe for buildings shall be at every floor level
above the first floor at:
a. at any private room or rentable space
b. storeroom
c. inside a mechanical/electrical room
d. a landing of an enclosed stairway
85.
The general term for the hot or cold water pipes
containing potable water
a. water plumbing pipes
b. water distribution pipes
c. hot or cold water line
d. water supply pipes
85.
The general term for the hot or cold water pipes
containing potable water
a. water plumbing pipes
b. water distribution pipes
c. hot or cold water line
d. water supply pipes
86.
Single lever valves used in kitchen sink and lavatory
faucets or at shower valves has gain popularity in
plumbing installation today. This is because these valves
are beautiful and are maintenance-free. These valves
work by the principle of a:
A. gate valve
B. angle valve
C. ball valve
D. globe valve
86.
Single lever valves used in kitchen sink and lavatory
faucets or at shower valves has gain popularity in
plumbing installation today. This is because these valves
are beautiful and are maintenance-free. These valves
work by the principle of a:
A. gate valve
B. angle valve
C. ball valve
D. globe valve
87.
Minimum water delivery in liters per minute for an
outlet of a wet standpipe at a residual pressure or 1.8
kilos per sq. mts.
a. 132 liters per minute
b. 112 liters per minute
c. 155 liters per minute
d. 126 liters per minute
87.
Minimum water delivery in liters per minute for an
outlet of a wet standpipe at a residual pressure or 1.8
kilos per sq. mts.
a. 132 liters per minute
b. 112 liters per minute
c. 155 liters per minute
d. 126 liters per minute
88.
It is customary that a full open type of valve is used in
several locations in a water distribution system. Which
location in the following list DOES not require one?
a. On every hose bibb
b. On water supplies to pressurized tank
c. On the water service pipe near the source connection
d. On the main water distribution pipe near the water
service
88.
It is customary that a full open type of valve is used in
several locations in a water distribution system. Which
location in the following list DOES not require one?
a. On every hose bibb
b. On water supplies to pressurized tank
c. On the water service pipe near the source connection
d. On the main water distribution pipe near the water
service
89.
In a water system with constant water supply supplying
series of plumbing fixtures, water supply drop is
experience when the fixtures in the series are
simultaneously opened. Which poor design in the
plumbing system causes this?
a. Choice in the system of water distribution
b. Insufficiency in the size of the water service and
distribution pipe
c. Too many fixtures opened simultaneously
d. Use of PVC or other plastic pipes
89.
In a water system with constant water supply supplying
series of plumbing fixtures, water supply drop is
experience when the fixtures in the series are
simultaneously opened. Which poor design in the
plumbing system causes this?
a. Choice in the system of water distribution
b. Insufficiency in the size of the water service and
distribution pipe
c. Too many fixtures opened simultaneously
d. Use of PVC or other plastic pipes
90.
In a water distribution system, locations such as supply
pipe to every water heater requires a full open valve.
Which of the following in the list is a full open valve?
a. check valve
b. ball valves
c. globe valve
d. angle valve
90.
In a water distribution system, locations such as supply
pipe to every water heater requires a full open valve.
Which of the following in the list is a full open valve?
a. check valve
b. ball valves
c. globe valve
d. angle valve
91.
Branch vents are required to have at least a slope 1/4”
per feet. The purpose of which is:
a. for convenience in installing the pipe
b. to facilitate air movement with lesser air resistance
c. for purposes of economy
d. to allow any waste to drain into the drain pipe
91.
Branch vents are required to have at least a slope 1/4”
per feet. The purpose of which is:
a. for convenience in installing the pipe
b. to facilitate air movement with lesser air resistance
c. for purposes of economy
d. to allow any waste to drain into the drain pipe
92.
It is a kind of valve which its mechanism for the
automatic release of a substance from a boiler, pressure
vessel or other system when the pressure or
temperature
exceeds preset limits.
a. safety valve
b. foot valve
c. angle valve
d. plug valve
92.
It is a kind of valve which its mechanism for the
automatic release of a substance from a boiler, pressure
vessel or other system when the pressure or
temperature
exceeds preset limits.
a. safety valve
b. foot valve
c. angle valve
d. plug valve
93.
1. A vent used in a battery of plumbing fixtures where
the vent is installed in front of the last fixture of the
battery.
A. yoke vent
B. circuit vent
C. stack vent
D. relief vent
93.
1. A vent used in a battery of plumbing fixtures where
the vent is installed in front of the last fixture of the
battery.
A. yoke vent
B. circuit vent
C. stack vent
D. relief vent
94.
Manually operated valve with its outlet opening
oriented at right angles to its inlet opening.
a. angle valve
b. foot valve
c. safety valve
d. gate valve
94.
Manually operated valve with its outlet opening
oriented at right angles to its inlet opening.
a. angle valve
b. foot valve
c. safety valve
d. gate valve
95.
A type of check valve and placed at the pumps wet well.
a. foot valve
b. angle valve
c. safety valve
d. gate valve
95.
A type of check valve and placed at the pumps wet well.
a. foot valve
b. angle valve
c. safety valve
d. gate valve
96.
It is an alloy of cast iron & silicon and installed in
chemical laboratories.
a. ductile cast iron
b. acid resistant cast iron pipe
c. centrifugal cast iron pipe
d. hub and spigot pipe
96.
It is an alloy of cast iron & silicon and installed in
chemical laboratories.
a. ductile cast iron
b. acid resistant cast iron pipe
c. centrifugal cast iron pipe
d. hub and spigot pipe
97.
It is the cheapest and light weight among the sewer
pipes. It is recommended for house sewer and septic
tank.
a. bituminous fiber sewer pipe
b. vitrified clay pipe
c. cast iron pipe
d. series 600 PVC
d. series 600 PVC
97.
It is the cheapest and light weight among the sewer
pipes. It is recommended for house sewer and septic
tank.
a. bituminous fiber sewer pipe
b. vitrified clay pipe
c. cast iron pipe
d. series 600 PVC
d. series 600 PVC
98.
It is an alloy of cast iron & silicon and installed in
chemical laboratories.
a. ductile cast iron
b. acid resistant cast iron pipe
c. centrifugal cast iron pipe
d. hub and spigot pipe
98.
It is an alloy of cast iron & silicon and installed in
chemical laboratories.
a. ductile cast iron
b. acid resistant cast iron pipe
c. centrifugal cast iron pipe
d. hub and spigot pipe
99.
It is the portion of the roadway section adjacent to the
curb which utilized to convey stormwater runoff.
a. gutter
b. inlet
c. culvert
d. catch basin
99.
It is the portion of the roadway section adjacent to the
curb which utilized to convey stormwater runoff.
a. gutter
b. inlet
c. culvert
d. catch basin
100.
Closed conduit whose purpose is to convey surface
water under a roadway, railroad or other impediment.
a. culvert
b. drop inlet
c. gutter
d. catch basin
100.
Closed conduit whose purpose is to convey surface
water under a roadway, railroad or other impediment.
a. culvert
b. drop inlet
c. gutter
d. catch basin
PLUMBING BANK 4
5
1. Which material ultimately seals a caulked or bell and
spigot joint?
o Cement
o Oakum
o Pig lead
o Coal tar
1. Which material ultimately seals a caulked or bell and
spigot joint?
o Cement
o Oakum
o Pig lead
o Coal tar
2. What do you call the process in which all types of
iron-based metals rust?
o Oxidation
o Pit corrosion
o Material breakdown
o Tuberculation
2. What do you call the process in which all types of
iron-based metals rust?
o Oxidation
o Pit corrosion
o Material breakdown
o Tuberculation
3. Which pipe support is recommended in holding a
single horizontal soil or waste branch?
o Clevis
o Bracket
o Trapeze
o Clamp hanger
3. Which pipe support is recommended in holding a
single horizontal soil or waste branch?
o Clevis
o Bracket
o Trapeze
o Clamp hanger
4. Which of these pipes is measured by its outside
diameter?
o Galvanized steel pipe
o Cast iron pipe
o Copper pipe
o Concrete pipe
4. Which of these pipes is measured by its outside
diameter?
o Galvanized steel pipe
o Cast iron pipe
o Copper pipe
o Concrete pipe
5. Pressure loss in pipe due to its interior surface is
attributed to what factor?
o Friction loss
o Static pressure
o Dynamic head
o Water flow
5. Pressure loss in pipe due to its interior surface is
attributed to what factor?
o Friction loss
o Static pressure
o Dynamic head
o Water flow
6. Which plastic pipe is normally oval in cross section
and is denoted by it outside diameter?
o PP (Polypropylene)
o CPVC (Chlorinated polyvinyl chloride)
o PB (Polybutylene)
o SR (Styrene rubber)
6. Which plastic pipe is normally oval in cross section
and is denoted by it outside diameter?
o PP (Polypropylene)
o CPVC (Chlorinated polyvinyl chloride)
o PB (Polybutylene)
o SR (Styrene rubber)
7. Ventilating system is essential in sanitary drainage
system. Providing such system prevents ___.
o Backpressure
o Siphonage
o Backflow
o All of these
7. Ventilating system is essential in sanitary drainage
system. Providing such system prevents ___.
o Backpressure
o Siphonage
o Backflow
o All of these
8. The following are types of joints used in plastic pipes.
Which of these is NOT applicable?
o Crimped joint
o Solvent cement weld joint
o Heat fusion joint
o Hot poured joint
8. The following are types of joints used in plastic pipes.
Which of these is NOT applicable?
o Crimped joint
o Solvent cement weld joint
o Heat fusion joint
o Hot poured joint
9. What is the rod used for caulking oakum?
o Soldering rod
o Glass rod
o Yarning iron
o Stadia rod
9. What is the rod used for caulking oakum?
o Soldering rod
o Glass rod
o Yarning iron
o Stadia rod
10. What is the science that studies water in motion?
o Fluid mechanics
o Hydrokinetic
o Hydraulics
o Hydrology
10. What is the science that studies water in motion?
o Fluid mechanics
o Hydrokinetic
o Hydraulics
o Hydrology
11. Potable water is to water supply, as wastewater is to
___.
o Sewer system
o Fire protection
o Vent system
o Storm/drainage system
11. Potable water is to water supply, as wastewater is to
___.
o Sewer system
o Fire protection
o Vent system
o Storm/drainage system
12. Also known as the Sanitation Code of the Philippines.
o RA 8749
o RA 9275
o RA 9003
o PD 856
12. Also known as the Sanitation Code of the Philippines.
o RA 8749
o RA 9275
o RA 9003
o PD 856
13. Portion of the septic tank where retention of sludge
takes place.
o Digestive chamber
o Holding tank
o Leaching chamber
o Polishing chamber
13. Portion of the septic tank where retention of sludge
takes place.
o Digestive chamber
o Holding tank
o Leaching chamber
o Polishing chamber
14. MWSS stands for:
o Metro Water and Sewer System
o Metropolitan Waterworks and Sewerage System
o Manila Water and Sewer System
o Manila Waterworks, Sewerage and Sanitation
14. MWSS stands for:
o Metro Water and Sewer System
o Metropolitan Waterworks and Sewerage System
o Manila Water and Sewer System
o Manila Waterworks, Sewerage and Sanitation
15. ___ is the removal of salts from saline water to
provide freshwater.
o Decantation
o Desalination
o Hypertension
o Condensation
15. ___ is the removal of salts from saline water to
provide freshwater.
o Decantation
o Desalination
o Hypertension
o Condensation
16. It is a natural or manmade structure for storing,
regulating, and controlling water.
o Reservoir
o Sewer
o Faucet
o Catch basin
16. It is a natural or manmade structure for storing,
regulating, and controlling water.
o Reservoir
o Sewer
o Faucet
o Catch basin
17. It is a tank used to contain domestic wastes to allow
the settling of solids prior to distribution to a leach field
for soil absorption. This tank is used when a sewer line is
not available to carry them to a treatment plant.
o Cistern
o Septic tank
o Dam
o Lagoon
17. It is a tank used to contain domestic wastes to allow
the settling of solids prior to distribution to a leach field
for soil absorption. This tank is used when a sewer line is
not available to carry them to a treatment plant.
o Cistern
o Septic tank
o Dam
o Lagoon
18. What is the term applied to water which enters
sewers through poor joints, cracked pipes, and the
walls?
o Infiltration
o Penetration
o Inflow
o Seepage
18. What is the term applied to water which enters
sewers through poor joints, cracked pipes, and the
walls?
o Infiltration
o Penetration
o Inflow
o Seepage
19. What are the pathogenic bacteria that can survive in
natural water without protection in particular matter of
other physical protection long enough to transmit
disease to human beings?
o E. coli
o Amoeba
o Mushroom
o Filarial
19. What are the pathogenic bacteria that can survive in
natural water without protection in particular matter of
other physical protection long enough to transmit
disease to human beings?
o E. coli
o Amoeba
o Mushroom
o Filarial
20. What kind of pipe is remarkably suited to
embedment in concrete structure and can be used as
soil, waste or ventilation pipe and downspout?
o Galvanized wrought iron pipe
o Galvanized steel pipe
o Asbestos pipe
o Cast iron pipe
20. What kind of pipe is remarkably suited to
embedment in concrete structure and can be used as
soil, waste or ventilation pipe and downspout?
o Galvanized wrought iron pipe
o Galvanized steel pipe
o Asbestos pipe
o Cast iron pipe
21. What is the slope of soil branch has been proven to
be effective and satisfactory?
o 2.50%
o 3%
o 1.50%
o 2%
21. What is the slope of soil branch has been proven to
be effective and satisfactory?
o 2.50%
o 3%
o 1.50%
o 2%
22. A title given to a person who is a skilled worker in
the field of plumbing. It is derived from the Ancient
Roman term ‘plumbarius’ which was taken from the
Latin word ‘plumbum.’
o Plumber
o Engineer
o Architect
o Worker
22. A title given to a person who is a skilled worker in
the field of plumbing. It is derived from the Ancient
Roman term ‘plumbarius’ which was taken from the
Latin word ‘plumbum.’
o Plumber
o Engineer
o Architect
o Worker
23. Its main function is to prevent reversal of flow in the
line. Valves of these types are recommended for gas,
water, steam, air and general vapor services.
o Plug disk valve
o Check valve
o Composition valve
o Conventional valve
23. Its main function is to prevent reversal of flow in the
line. Valves of these types are recommended for gas,
water, steam, air and general vapor services.
o Plug disk valve
o Check valve
o Composition valve
o Conventional valve
24. ___ is used mainly to completely close or open the
line but not necessarily to control the flow of water.
o Globe valve
o Gate valve
o Check valve
o Angle valve
24. ___ is used mainly to completely close or open the
line but not necessarily to control the flow of water.
o Globe valve
o Gate valve
o Check valve
o Angle valve
25. A device used to prevent water hammering.
o Sump pit
o Air chamber
o Cistern
o Vent
25. A device used to prevent water hammering.
o Sump pit
o Air chamber
o Cistern
o Vent
26. It refers to the demand considered in determining
the size of water service pipe when simultaneously used
at the same time.
o Peak load
o Probable demand
o Both a and b
o Maximum demand
26. It refers to the demand considered in determining
the size of water service pipe when simultaneously used
at the same time.
o Peak load
o Probable demand
o Both a and b
o Maximum demand
27. The connection between the city water main and the
service pipe is called ___.
o Service pipe
o Main pipe
o Riser
o Corporation stop
27. The connection between the city water main and the
service pipe is called ___.
o Service pipe
o Main pipe
o Riser
o Corporation stop
28. The process of removing suspended water from
water supply by allowing time and inactivity of water to
do the work of settling out heavier suspended particles.
o Coagulation
o Oxidation
o Sedimentation
o Disinfection
28. The process of removing suspended water from
water supply by allowing time and inactivity of water to
do the work of settling out heavier suspended particles.
o Coagulation
o Oxidation
o Sedimentation
o Disinfection
29. A water supply pipe that extends one full storey or
more to convey water to branches or to a group of
fixture.
o Riser
o Distribution pipe
o Service pipe
o Developed length
29. A water supply pipe that extends one full storey or
more to convey water to branches or to a group of
fixture.
o Riser
o Distribution pipe
o Service pipe
o Developed length
30. A compression stop valve installed on the outside of
a building so that the garden hose may be attached.
a. Sill cock
b. Pressure regulating valve
c. Stop valve
d. None of the above
30. A compression stop valve installed on the outside of
a building so that the garden hose may be attached.
a. Sill cock
b. Pressure regulating valve
c. Stop valve
d. None of the above
31. Existing pressure without any flow motion.
o Standby pressure
o Static pressure
o Residual pressure
o Reserved pressure
31. Existing pressure without any flow motion.
o Standby pressure
o Static pressure
o Residual pressure
o Reserved pressure
32. Island fixture requires this type of venting. What is
it?
o Looped vent
o Circuit vent
o Revent
o Loop vent
32. Island fixture requires this type of venting. What is
it?
o Looped vent
o Circuit vent
o Revent
o Loop vent
33. Which of the following is among the types of
material pipe support used for vertical application?
o Clevis
o metal Strap
o Bracket
o Trapeze
33. Which of the following is among the types of
material pipe support used for vertical application?
o Clevis
o metal Strap
o Bracket
o Trapeze
34. What type of trap may be used on the house drain
immediately before the house sewer?
o House trap
o Running trap
o Grease trap
o S trap
34. What type of trap may be used on the house drain
immediately before the house sewer?
o House trap
o Running trap
o Grease trap
o S trap
35. Originally, Sovent System uses what type of material
for its drainage, aerator and de-aerator fittings?
o Copper
o Cast iron
o Plastic
o Galvanized iron
35. Originally, Sovent System uses what type of material
for its drainage, aerator and de-aerator fittings?
o Copper
o Cast iron
o Plastic
o Galvanized iron
36. Sovent system is an engineered plumbing system
which involves the use of _____.
o Soil and waste pipes, aerator and de-aerator
o Soil and waste pipes, vent pipes, aerator fitting and de-
aerator fitting
o Soil and waste pipes, aerator fittings, vent pipes
o Soil and waste pipes, de-aerator fittings, and vent pipes
36. Sovent system is an engineered plumbing system
which involves the use of _____.
o Soil and waste pipes, aerator and de-aerator
o Soil and waste pipes, vent pipes, aerator fitting and de-
aerator fitting
o Soil and waste pipes, aerator fittings, vent pipes
o Soil and waste pipes, de-aerator fittings, and vent pipes
37. In the design of septic tank, the capacity of leaching
chamber is generally _____.
o ½ the volume of DC
o ¾ the volume of DC
o ¼ DC volume
o Same size as DC
37. In the design of septic tank, the capacity of leaching
chamber is generally _____.
o ½ the volume of DC
o ¾ the volume of DC
o ¼ DC volume
o Same size as DC
38. What is the color for a pipeline containing gases in
either gaseous or liquefied form, vapors and
pneumatically conveyed fumes and materials?
o Yellow ochre
o Silver-grey
o Green
o Safety yellow (ANSI)
38. What is the color for a pipeline containing gases in
either gaseous or liquefied form, vapors and
pneumatically conveyed fumes and materials?
o Yellow ochre
o Silver-grey
o Green
o Safety yellow (ANSI)
39. What specific qualities are required of a plumbing
fixture?
a. Impervious surface
b. Free from defects
c. Free from concealed fouling surfa
d. All of the above
39. What specific qualities are required of a plumbing
fixture?
a. Impervious surface
b. Free from defects
c. Free from concealed fouling surfa
d. All of the above
40. A grease interceptor may be required in any of the
following EXCEPT in _____.
o Commercial establishment
o Institutional buildings
o Single-Family Residential dwellings
o Multi-family Residential dwelling
40. A grease interceptor may be required in any of the
following EXCEPT in _____.
o Commercial establishment
o Institutional buildings
o Single-Family Residential dwellings
o Multi-family Residential dwelling
41. It is a copper pipe that can be used in water
distribution system above and underground pipe
installation.
o Type K
o Type L
o Type M
o Type DWV
41. It is a copper pipe that can be used in water
distribution system above and underground pipe
installation.
o Type K
o Type L
o Type M
o Type DWV
42. Identify the picture shown.
o Fitting
o Coupling
o Elbow
o Union
42. Identify the picture shown.
o Fitting
o Coupling
o Elbow
o Union
43. Identify the picture shown.
o Combination wye
o Super wye
o Upright wye
o Vertical wye
43. Identify the picture shown.
o Combination wye
o Super wye
o Upright wye
o Vertical wye
44. Identify the picture shown.
o Permanent plug
o Test plug
o Permanent cap
o Test cap
44. Identify the picture shown.
o Permanent plug
o Test plug
o Permanent cap
o Test cap
45. Identify the picture shown.
o Nipple
o Bushing
o Coupling
o Union
45. Identify the picture shown.
o Nipple
o Bushing
o Coupling
o Union
46. Identify the figure shown.
o Tee
o Sanitary Tee
o Drain tee
o Combination wye
46. Identify the figure shown.
o Tee
o Sanitary Tee
o Drain tee
o Combination wye
47. Identify the picture shown.
o Victaulic coupling
o Closing flange
o Pipe Clamp
o Trapeze
47. Identify the picture shown.
o Victaulic coupling
o Closing flange
o Pipe Clamp
o Trapeze
48. This configuration of sprinkler is called ______.
o Upright
o Side wall
o Pendent
o Concealed
o None of these
95. Which of the following specifically
characterize a tapped tee?
o Its barrel is internally threaded
o Both barrel and branch are externally
threaded
o Its branch is externally threaded
o None of these
96. What system of drainage is provided to
allow water to seep through a system of
perforated pipes?
o Seepage pit
o Drainpool
o Building sub-drain
o Subsoil-drain
96. What system of drainage is provided to
allow water to seep through a system of
perforated pipes?
o Seepage pit
o Drainpool
o Building sub-drain
o Subsoil-drain
97. Theoretically, which part of the water and
distribution system pipe is the largest?
o Riser
o Fixture supply pipe
o Building supply pipe
o Fixture branch pipe
97. Theoretically, which part of the water and
distribution system pipe is the largest?
o Riser
o Fixture supply pipe
o Building supply pipe
o Fixture branch pipe
97. Theoretically, which part of the water and
distribution system pipe is the largest?
o Riser
o Fixture supply pipe
o Building supply pipe
o Fixture branch pipe
98. A hose bib is a kind of faucet with?
o Outside thread
o Inside thread
o Flange end
o Welded end
98. A hose bib is a kind of faucet with?
o Outside thread
o Inside thread
o Flange end
o Welded end
98. A hose bib is a kind of faucet with?
o Outside thread
o Inside thread
o Flange end
o Welded end
99. Which type of vent may be connected to a
branch vent?
o Looped vent
o Circuit vent
o Individual vent
o All of these
99. Which type of vent may be connected to a
branch vent?
o Looped vent
o Circuit vent
o Individual vent
o All of these
100. A plumbing unit consists of the following
except:
o Bidet
o Water meter
o Lavatory
o Floor drain
100. A plumbing unit consists of the following
except:
o Bidet
o Water meter
o Lavatory
o Floor drain