Mechanical pressure gauges • General informations: . . . . . . . . . . . . . . . 3
Selection criteria, measurement setup, installation . . . . . . . . . . . . . . . . . 3
Contact Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Version: EN 837-1
Nominal case size: 100, 160, 250
Accuracy:
1.0 (EN 837-1/6)
Pressure ranges:
EN 8 3 7 - 1 / 5 (0..0.6 bar up to 0..1600 bar)
as well as all equivalent ranges for negative and/or negative
and positive excess pressure
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1 . 3 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +60°C (soldered)
+100°C (brazed)
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K
of the respective scale value
Protection class:
IP 54 (EN 60 529/ I E C 5 2 9 )
Standard version:
Options:
Connection:
• Case size 100, 1 6 0 with glycerin filling
brass at the bottom or at the rear off-center (EN 836-1/7.3)
G 1/2 B, AF 22 • adjustable red pointer on the scale
Bourdon tube type: • from outside adjustable pointer or trailing pointer, resettable
up to 40 bar: circular spring, bronze, soft-soldered • front flange stainless steel
up to 60 bar: screw spring, stainless steel 1.4571, brazed
• clamp fixing ring stainless steel
Movement:
• rear flange stainless steel
brass, moving parts Argentan
• movement wear resistant (brass/ polyacetal) or wear and
Dial: corrosion resistant (stainless steel)
aluminium white, figures black (DIN 16 1 0 9 )
• version for higher temperatures
Pointer: • version for oxygen, free of oil and grease
aluminium black
• version for refrigerating plants with temperature scaling for
refrigerants (e.g. R22, NH3)
Casing:
stainless steel 1 . 4 3 0 1
Electrical additional components:
Ring: • contact devices
stainless steel 1 . 4 3 0 1
• pressure transducer
Window:
instrument glass
Configurations and Dimensions Type MRE
Dimensions (mm)
Size D D1 a a1 b b1 c c1 c2 c3 d1 d2 d3 e g
1)
with liquid, structural shape with front flange or front flange with welded mounting brackets should be preferred
2)
version consists of fixed front flange with slots and loose cover ring
3)
only dry version available
4)
version consists of welded mounting brackets and loose front flange
5)
not size 250
6)
size 250 with mounting brackets
subject to technical modification
SIKA Bourdon Tube Pressure Gauge Type MRE, standard and stainless steel version
Application range:
Gaseous and liquid, non-high viscous, non-crystallizing
media, in stainless steel version also applicable under
aggressive process media and environmental conditions
Version: EN 837-1
Nominal case size: 63
Accuracy: (EN 837-1/6)
1 . 6 0/400 bar
2.5 0/600 bar standard version
0/100 bar chemical version
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1 . 3 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +60°C (soldered)
+100°C (brazed)
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K Options:
of the respective scale value
• with glycerin filling
Protection class:
IP 54 (EN 60 529 / IEC 529) • safety version EN 837-1 (s)
• adjustable red pointer on the dial.
Connection:
brass at the bottom or at the rear off-center (EN 836-1/7.3) • from outside adjustable pointer or trailing pointer, resettable
G 1/4B, A F 1 4 starting from 0/2.5 bar
• clamp fixing ring stainless steel
Standard version:
• version for oxygen, free of oil and grease
Connection material: brass
• front flange stainless steel
Bourdon tube type:
• rear flange stainless steel
up to 40 bar: circular spring, bronze, soldered
up to 60 bar: screw spring 1.4571, brazed
Stainless steel version:
Movement:
brass, moving parts Argentan Connection material: stainless steel 1.4571
Bourdon tube type:
Dial: up to 40 bar: circular spring, 1.4571 welded with shielding gas
aluminium white, figures black up to 60 bar: screw spring 1.4571, welded with shielding gas
Movement:
Pointer:
stainless steel 1 . 4 3 0 1
aluminium black
Dial:
Casing: aluminium white, scaling black
stainless steel 1.4301
Casing:
stainless steel 1.4301
Ring:
stainless steel 1.4301 Ring:
bayonet ring, stainless steel 1.4301
Window: Window:
instrument glass
laminated safety glass
Configurations and Dimensions Type MRE standard and stainless steel version
Dimensions (mm)
Size D a a1 b b1 b2 b3 c c1 c2 c3 d1 d2 d 3
63 64 12,5 15,5 35 36 37,5 38,5 5 2 13 13 75 QC 3,7
1)
casing shape consists of a front ring with slots and separate front flange
SIKA Bourdon Tube Pressure Gauge Type MRS
Application range:
Gaseous and liquid, non-high viscous, non-crystallizing
media
Version: EN 837-1
Accuracy:
1.0 (EN 837-1/6)
Pressure ranges:
EN 837-1/5 0..0.6 bar up to 0..1600 bar
as well as all equivalent ranges for negative and/or negative
and positive excess pressure
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1 . 3 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +60°C (soldered)
+100°C (brazed)
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K
of the respective scale value
Protection class:
IP 54 (EN 60 529 /IEC 529)
Dimensions (mm)
Size D a a1 b b1 c c1 c2 c3 d1 d2 d3 d4 e g
160 161 15,5 19 51 54 6 5 20 21,5 178 196 5,8 167 52 92,5
250 251 15,5 17,5 55 57 6 5 20 21,5 270 285 5,8 - 52 97
Size 91 G G1 G2 h hi s s1 s2 s3 s4 s5 sw SW1
—M 2 0 x— 1,5
1 — — — ———
160 94 G½A /2 "NPT 118 119,5 2 6 6 1 - - 22 17
1
250 98,5 G½A /2"NP M 20 x 1 ,5 165 166,5 - 2 - - - - 22 17
1)
with liquid, s t r u c t u r a l shape w i t h f r o n t f l a n g e or f r o n t f l a n g e w i t h welded mounting b r a c k e t s should be p r e f e r r e d
2)
version c o n s i s t s of f i x e d f r o n t ring with slots and loose c o v e r r i n g
3)
o n l y dry v e r s i o n available
4)
version c o n s i s t s of welded mounting b r a c k e t s and loose f r o n t f l a n g e
5)
not size 250
6)
s i z e 250 w i t h w e l d e d mounting b r a c k e t s
s u b j e c t to technical modification
SIKA Bourdon Tube Pressure Gauge Type MRE, stainless steel version
Application range:
Gaseous and liquid, non-high viscous, non-crystallizing
media, also applicable under aggressive process media and
environmental conditions
Version: EN 837-1
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1.3 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax:+100°C
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K
of the respective scale value
Protection class:
IP 54 (EN 60 529 / IEC 529)
Standard version:
Options:
Connection:
stainless steel 1.4571 at the bottom or at the rear off-center • case sizes 100, 1 6 0 with glycerin filling
(EN 837-1/7.3), G 1/ 2 B, AF 22
• safety version EN 837-1 (s)
Bourdon tube type:
up to 40 bar: circular spring, stainless steel 1.4571 welded • adjustable red pointer on the dial
with shielding gas • from outside adjustable pointer or trailing pointer, resettable
up to 60 bar: screw spring stainless steel 1.4571 welded
with shielding gas • front flange stainless steel
Movement: • clamp fixing stainless steel
stainless steel 1 . 4 5 7 1
• back flange stainless steel
Dial:
aluminium white, figures black • version for higher temperatures
Dimensions (mm)
Size D D1 a a1 b b1 c c1 c2 c3 d1 d2 d3 e g
100 101 106 20 23,5 55 58,5 6 3 20 19 116 132 4,8 30 97
160 161 167 15,5 19 51 54 6 3 20 19 178 196 5,8 52 92,5
250 251 - 15,5 17,5 55 57 6 3 20 19 270 285 5,8 52 97
Size g1 G G1 G2 h hi s s1 s2 s3 04 SW SW1
100 96 G1 /2B ½"NPT M 20 x 1 ,5 87 84 2 6 6 1 10 22 17
1
160 91,5 G /2B ½"NPT M 2 0 x 1,5 118 117 2 6 6 1 - 22 17
1 ½
250 96 G /2 B "NPT M 20x1, 5 165 164 - 2 - - - 22 17
1>
with liquid filling, structural shape with front flange or front flange with welded mounting brackets should be preferred
2)
version consists of fixed front flange with slots and loose cover ring
3)
only dry version available
4)
version consists of welded mounting brackets and loose front flange
5)
not size 250
6>
size 250 with welded mounting brackets
subject to technical modification
SIKA Bourdon Tube Pressure Gauges with Limit-Switch Contact Assemblies
Type MRS case mild steel
Type MRE case stainless steel 1.4301
Dimensions (mm)
Size a a1 B B1 D g2 h±1 m o 01 02 r r1 r2 r3 r6 r7 r9
1) 1)
100 16 18 103 106 101 142 87 31 4 37 21 88 25 23 32 12 18 0
160 16 18 105,52) 1 0 82 ) 161 146 118 31 2 37 21 117 27 36 50 12 36 50
1)
dimension for a maximum of 3 contacts enclosed
2)
dimension for a maximum of 2 contacts enclosed. Dimensions B and B1 increase by 10 mm for types I 1 1 and I 1 2
3)
with liquid filling, version front ring with welded mounting brackets should be preferred
4)
version with front flange consists of fixed front ring with slots and loose cover ring
5)
version consists of welded mounting brackets and front flange
6)
only dry version available
subject to technical modification
SIKA Bourdon Tube Test Pressure Gauge Type MFS
Application range:
Gaseous and liquid, non-high viscous, non-crystallizing
media
Accuracy:
0.6 (EN 837-1/6)
Pressure ranges:
EN 837-1/5 0..0.6 bar up to 0..1600 bar
as well as all equivalent ranges for negative and/or negative
and positive excess pressure
Calibration medium:
<25 bar: gas
>25 bar: oil
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1.3 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +60°C (soft-soldered)
+100°C (brazed)
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K
Ring:
of the respective scale value
bayonet ring mild steel painted black
Protection class:
Window:
IP 54 (EN 60 529 / IEC 529) instrument glass
Casing:
mild steel painted black
Configurations and Dimensions Type MFS
Dimensions (mm)
Size D a a1 b b1 C C1 C2 c3 d1 d2 d3 d4 e g
160 161 15,5 19 51 54 6 5 20 21,5 178 196 5,8 167 52 92,5
250 251 15,5 17,5 55 57 6 5 20 21,5 270 285 5,8 - 52 97
Size g1 G G1 G2 h hi s s1 s2 S3 s4 sw SW1
160 94 G 1/2 A '/2 "NP M 20 x 1 ,5 118 119,5 2 6 6 1 - 22 17
1 1
250 98,5 G /2 A /2"NP M 20 x 1 ,5 165 166,5 - 2 - - - 22 17
1)
with liquid filling, structural shape with front flange or front flange with welded mounting brackets should be preferred
2)
version consists of fixed front flange with slots and loose cover ring
3)
only dry version available
4)
version consists of welded mounting brackets and loose front flange
5)
not size 250 mm
6)
size 250 with welded mounting brackets
Accuracy:
0.6 (EN 837-1/6)
Pressure ranges:
EN 837-1/5 0..0.6 bar up to 0..1600 bar
as well as all equivalent ranges for negative and/or negative
and positive excess pressure
Adjustment medium:
<25 bar: gas
>25 bar: oil
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1.3 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax:+100°C
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K Ring:
of the respective scale value bayonet ring stainless steel 1 . 4 3 0 1
Standard version:
Options:
Connection:
• size 1 6 0 with glycerin filling
stainless steel 1.4571 at the bottom or at the rear off-center
(NG 1 6 0 only) (EN 837-1/7.3) G 1 /2 B, AF 22 • movement stainless steel (stone bearing)
Movement:
brass, moving parts Argentan
Electrical additional components:
available with some limitations
Dial:
aluminium white, figures black • contact devices
• pressure transducer
Pointer:
aluminum black
Casing:
stainless steel 1 . 4 3 0 1
Configurations and Dimensions Type MFE
Dimensions (mm)
Size D a a1 b b1 c c1 c2 C3 d1 d2 d3 d4 e g
160 161 15,5 19 51 54 6 5 20 21,5 178 196 5,8 167 52 92,5
250 251 15,5 17,5 55 57 6 5 20 21,5 270 285 5,8 - 52 97
Size g1 G G1 G2 h h1 s S1 s2 s3 s4 SW SW1
1 1
160 94 G / 2A / 2"NPT M 20 x 1 ,5 118 119,5 2 6 6 1 - 22 17
1 1
250 98,5 G / 2A / 2 "NP M20x 1,5 165 166,5 - 2 - - - 22 -
1)
with liquid filling, structural shape with front flange or front flange with welded mounting brackets should be preferred
2)
version consists of fixed front flange with slots and loose cover ring
3)
only dry version available
4)
version consists of welded mounting brackets and loose front ring
5)
not size 250 mm
6)
size 250 with welded mounting brackets
Version: EN 837-3
Accuracy:
1 . 6 (EN 837-3/6)
Technical range:
≤0.6 bar: 5 x full scale value
>0.6 up to 2.5 bar: 3 x full scale value
>2.5 bar: 5 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +100°C
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.5% /10 K
temperature decrease: about -0.5% /10 K Ring:
of the respective scale value slip-on ring, mild steel painted black
Standard version:
Options:
Connection:
lower measurement flange mild steel (EN 836-3/7.3) • movement wear and corrosion resistant (stainless steel)
G 1/2 B, AF 22
• window acrylic glass or laminated safety glass
Measurement unit: • adjustable red pointer on the dial
0/10 up to 400 mbar:
diaphragm spring stainless steel 1.4571, measurement flange • from outside adjustable pointer or trailing pointer, resettable
1 6 0 mm dia • version for higher temperature above +100°C
0/0,6 up to 0 / 1 , 6 bar:
diaphragm spring Duratherm, measurement flange 1 0 0 mm dia • open connection flange 2707a (see page 2 1 - 2 3 )
0/2,5 up to 0/25 bar:
diaphragm spring mild steel, measurement flange 1 0 0 mm dia • open connection flange acc. to DIN/ANSI (see page 2 1 - 2 3 )
• protection foil of PTFE, fine silver (chlorine), Tantalum etc.
Movement:
brass, moving parts Argentan • up to 10 times over range protection (face inscription
'10fach ü s') for measuring flange 1 0 0 mm: 40 bar max.
Dial: with measuring flange 1 6 0 mm: 2.5 bar max.
aluminium white, figures black
Electrical additional components:
Pointer: • contact devices
aluminum black
• pressure transducer
Casing:
Polyamid 6 B, black
Configurations and Dimensions Type MPS
bottom connection
Dimensions (mm)
Size flange ∅ d a b c c1 c2 c3 G G1 h±2 h1 ±2 AF
1/2 1
100 100 16 47 3 20 19 G A /2 "NPT 127 126 22
160 100 18 48 6 3 20 19 G1/2A 1
/2 "NPT 156 155 22
1 1
100 160 16 47 6 3 20 19 G /2A /2 "NPT 127 126 22
1 1
160 160 18 48 6 3 20 19 G /2A /2 "NPT 156 155 22
SIKA Diaphragm Pressure Gauge Type MPE, stainless steel version
Application range:
Gaseous and fluid media, with option 'open measurement
flange' also applicable with polluted and viscous media.
Version: EN 837-3
Accuracy:
1.6 (EN 837-3/6)
Technical range:
5 x scale value, 40 bar max.
Temperature limitations:
Environment: Tmin: -25°C, Tmax: +60°C
Measurement agent: Tmax: +100°C
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.5% /10 K
temperature decrease: about -0.5% /10 K
of the respective scale value
Protection class:
IP 54 (EN 60 529/I EC 529)
Ring:
Bayonet ring stainless steel 1.4301
Window:
laminated safety glass
Configurations and Dimensions Type MPE, stainless steel version
bottom connection
Dimensions (mm)
Size flange ∅ d a b c c1 c2 c3 G G1 h±2 h1 ±2 AF
1 1
100 100 20 55 6 5 20 21,5 G /2A /2 "NPT 127 128,5 22
1 1
160 100 20 55 6 5 20 21,5 G /2A /2 "NPT 157 158,5 22
100 160 20 55 6 5 20 21,5 G1/2A 1
/2 "NPT 127 128,5 22
1 1
160 160 20 55 6 5 20 21,5 G /2A /2 "NPT 157 158,5 22
Dimensions (mm)
h±2
flange ∅ d d3 d4 d6* f1 g k I X x1 x2 s
MPE MPE
size 1 00 size 160
100 63,5 10 60,3 12 6xM8 96 125 83 25 15 46 50 5
160 123 10 - 8xM8 96 125 140 25 15 46 - -
Dimensions (mm)
h±2
DN d1 d2 f f1 g k X
MP E NG 100 MP E NG 1 6 0
15 95 45 2 16 4x14 127 156 65 46
20 105 58 2 18 4x14 129 158 75 48
25 115 68 2 18 4x14 129 158 85 48
50 165 102 3 20 4x 18 137 166 125 56
Dimensions (mm)
h±2
DN d1 d2 f g k t X
MRE size 100 MRE size 1 6 0
15 100 45 2 4xM12* 111 140 65 12 30
20 105 58 2 4xM12* 111 140 75 12 30
25 115 68 2 4xM12* 111 140 85 12 30
50 165 102 3 4x ∅ 18 101 130 125 - 20
Dimensions (mm)
d d2 f g h ±2 bei 300 Ibs 2) k x
DN 150 Ibs 300 150 4x MPE MPE 150 Ibs 300 t 150 Ibs 300 Ibs 600 Ibs
600 Ibs
600 Ibs 300 Ibs UNF-2B size 1 00 size 1 60 600 Ibs
1
/2"
100 100 34,9 1,6 6,4 1/2-20 121 150 60,3 66,7 15 40 40 45
1" 108 124 50,8 1,6 6,4 5/8-1 81 ) 121 150 79,4 88,9 15 40 40 45
3
2" 152 165 92,1 1,6 6,4 5/8-18 ' 103 132 121 127 - 19,1 22,2 32
Other flange connections on request, e.g. with internal thread G1 or according to DIN 11851
* 4 inductive contact for type MPS only available with case size 160
* Contact devices with 4 limit contacts for type MPE are only available
with nominal case size 160 on request.
Pressure gauges having 3 or 4 limit contacts are not necessa- Pressure gauges with inductive contact have a cable connec-
rily adjustable with each other. When you order a pressure ting box.
gauge please indicate which of the needles must be adjus t -
able with each other and where the switching points lie. If the plug connector is installed at the rear side of an instru-
ment of nominal size NG 100, a Blow-out (25 mm dia) cannot
Miscellaneous be installed.
All type MPS pressure gauge with limit switches are splash-
proofed from front by a cellular rubber ring in the slip-on ring. The adjacent sketches show the precise position of connection
The window of the pressure gauge is made of acrylic glass. cable and plug connectors.
The window of type MPE is made of laminated safety glass. The plug connector has 6 pins and one earth terminal. The ter-
minal box has 6 terminals only.
Electrical connection
Pressure gauges of type MPS with electro-mechanical contact
devices (standard or magnet contact) are delivered ex factory
with connection cable in the rear wall of the casing and
1m cable length.
Generally all pressure gauges of type M PE and pressure gau
ges with oil filling are delivered with plug connector at the right-
hand side of the casing.
An exception are pressure gauges to be installed in panels,
the plug connector is positioned in the rear wall.
Configurations, Electrical Connection, Dimensions Type MPS, MPE
Compared with the base type, only the overall height differs can take the precise position of the connection cable and the
from each other, see table below. The other dimensions inclu- plug connectors from the sketches below. Different positions
ding open flanges can be taken from page 22 - 23. You are available on request with extra cost.
* with inductive limit signal switch type 1 1 1 or I22 the dimension B is increased by 17 mm.
Sizes f o r limit signal switches with 3 or 4 limit values and other special versions on request.
Application range:
Gaseous, dry, and non-aggressive media.
Version: EN 837-3
Accuracy:
1.6 (EN 837-3/6)
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +80°C
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K
of the respective scale value
Window:
Protection class: instrument glass
IP 54 (EN 60 529/ I E C 529)
Pointer:
aluminum black
Casing:
mild steel, painted black
stainless steel 1.4301 (size 100 only)
Ring:
bayonet ring, mild steel painted black
stainless steel 1.4301 (size 1 0 0 only)
Configurations and Dimensions Type MKS
Dimensions (mm)
Size a a1 b4) b15) D c c1 c2 C3 d1 d2 d3 d4 G
100 20 23,5 55 58,5 101 6 3 20 19 116 132 4,8 106 G1 / 2 B
160 15,5 19 51,5 55 161 6 3 20 19 178 196 5,8 168 G1 / 2 B
1)
recommended table drill hole (mm)
with front flange DN 100: ∅ 1 0 1 ± 1 DN 160: ∅ 1 6 2 + 1
with clamp fixing DN 100: ∅103 ±1 DN 160: ∅1 62+1
2)
version consists of fixed front flange with slots and loose cover ring
3)
brackets stainless steel, drawn blank
Version: EN 837-3
Accuracy:
1.6 (EN 837-3/6)
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
Temperature limitations:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax:+100°C
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K
of the respective scale value
Zero-point adjustment:
at front side
Dial:
aluminium white, figures black
Pointer:
aluminum black
Casing:
stainless steel 1 . 4 3 0 1
Ring:
bayonet ring, stainless steel 1 . 4 3 0 1
Configurations and Dimensions Type MKE
Dimensions (mm)
Size a a1 b4) b 15) D c c1 c2 c3 d1 d2 d3 d4 G
100 20 23,5 55 58,5 101 6 3 20 19 116 132 4,8 106 G1 / 2 B
160 15,5 19 51,5 55 161 6 3 20 19 178 196 5,8 168 G1 / 2 B
2)
version consists of fixed front flange with slots and loose cover ring
3)
brackets CrNi stainless steel, drawn blank
4)5)6)7)
measurement range for case size 160: 2.5 ... 16 mbar, dimensions b, b 1 , g , g 1 : + 5 m m
subject to technical modification
SIKA Differential Bourdon Tube Pressure Gauge Type MDS
Application range:
Measurement of differential pressure or of two different excess
pressures.
Gaseous and fluid, non-high viscous, non-crystallizing media.
Accuracy:
1.6 (EN 837-1/6)
Pressure ranges:
EN 837-1/5 0..0.6 bar up to 0..600 bar twin scale bar/ mWS.
Select the required reading range depending on the maximum
possible total pressure!
In heating systems with circulating pump operation, the total
excess pressure is normally equal to the hydrostatic pressure
plus the pump pressure.
Technical range:
static load: full scale value
fatigue load: 0.9 x full scale value
short-term: 1 . 3 x full scale value
Temperature limitation:
Ambient: Tmin: -25°C, Tmax: +60°C
Medium: Tmax: +60°C (soft-soldered)
+ 100°C (brazed)
Temperature dependence:
Reading error in case of deviation from standard temperature
by 20°C at the measurement system:
temperature increase: about +0.3% /10 K
temperature decrease: about -0.3% /10 K Ring:
of the respective scale value slip-on ring, mild steel painted black
Dial:
aluminium white, figures black (DIN 16 109)
Pointer:
1 Pointer: aluminum black
1 scale disk pointer: aluminium with 50% of the reading
range as positive and 50% negative differential pressure
reading
Casing:
mild steel painted black
Configurations and Dimensions Type MDS
bottom connection
with front flange
Dimensions (mm)
D = nominal size a a1 b b1 c c1 c2 c3 d1 d2
100 16 21 83 87 6 5 20 21,5 116 132
160 17 20 83 87 6 5 20 21,5 178 196
Switching functions
1)
When ordering, please indicate the
corresponding code number, e.g. M
12.
2)
The line ends and connection
clamps are analogically marked.
Earth wires are always green-yellow.
3)
The switching function is reserved
when the pointer moves in an anti-
clockwise direction.
Technical data magnet spring contact:
nominal insulating voltage: 61 - 300 V
nominal operating voltage: 250 V max.
nominal operating current: starting current respectively breacking current maxi 1.0 A
(continuous current: 0.6 A)
braking capacity: 30 W 50 VA
ambient temperature: -20 up to +60°C, or depending on the corresponding devices
Contact process is non-inductive.
Solenoid spring contacts are used with liquid filled pressure gauges.
2. Inductive limit contacts (I)
Basically the contactlessly working contact device is only used together with a transistor
relay. Depending on the application, control units with fail-safe control circuit (ex-version) or
with not fail-safe control circuit can be used. Principally control units must be installed out-
side the ex-zone. The NAMUR inductive contact works feedback-free, it is wear resistant,
maintenance free, corrosion resistant and meets the highest class of requirements.
Technical data
Voltage: 8 V DC
Current: 8 mA
ambient temperature: -20 up to +60°C, or depending on the corresponding devices
We recommend for liquid filled manometers the use of inductive contact devices. They are
more suitable than standard or magnet spring devices.
Switching functions
1)
When ordering, please indicate the corresponding code number, e.g. l1 1 .
2)
The line ends and connection clamps are analogically marked. Earth wires are always green-yellow.
3)
The switching function is reserved when the pointer moves in an anticlockwise direction.
Accessories
Stop Valves DIN 16 270-16 272
Application:
Stop and throttle device for pressure measurement instru-
ments to measure gases, vapors, and liquids. Device for zero-
point control and replacement of measurement instrument
while system is operational.
Versions:
• stop valve DIN 16270 without test connection
• stop valve DIN 16270 with test connection
• double stop valves DIN 16272 with separately
lockable test connection
Each with
shape A with clamping sleeve DIN 16283 or
shape B with shaft for measurement unit holder,
with nipple and turning sleeve
Stop valve with optional test connection provide simultaneous MZV22
connection for operating pressure measurement instruments
and test pressure measurement instruments in the pressure
pipe.
The test boss can be blocked off by a sealing pad and a sea-
ling cover, if the valve is designed to DIN 16271. In case of
DIN 16272, a second valve spindle is used for blocking off the
boss.
Stop valves are silicon-free.
Standard version:
Connection:
G 1/2 B acc. to DIN 16288, test connection M 20 x 1.5
Valve casing with vent screw
Options:
oil and grease free
certificate 3.1.B, DIN 50 049/ E N 1 o 2 0 4
connection M 20 x 1.5, 1/2 NPT
valves with PN 640 on request
technical changes reserved
Dimensions Manometer Stop Valves DIN 16 270-16 272
shape A, clamping sleeve / stud
shape B, nipple and union nut / stud, with shaft for measurement unit holder
stop valves DIN 1 6 2 7 1 with test flange 60x25x10, shape A stop valves DIN 16271 with test flange 60x25x10, shape AB
thread order-n° thread material
order-n° material
clamping sleeve stud clamping sleeve stud
1 1 1 1
MZV 30 G /2 G / 2B brass MZV 33 G /2 G / 2B brass
1 1 1 1
MZV 31 G /2 G / 2B mild steel MZV 34 G /2 G / 2B mild steel
1 1 1 1
MZV 32 G /2 G / 2B stainless steel 1.4571 MZV 35 G /2 G /2 B stainless steel 1.4571
stop valves DIN 16272 with test stud M 20 x 1 .5, shape A stop valves DIN 16272 with test stud M 20 x 1 .5, shape B
thread order-n° thread material
order-n° material
clamping sleeve stud clamping sleeve stud
1 1 1 1
G /2 G / 2B brass MZV 43 G /2 G /2 B brass
MZV 40
1 1 1 1
MZV 41 G /2 G / 2B mild steel MZV 44 G /2 G /2 B mild steel
Dimensions Manometer Stop Valves DIN 16 270-16 272
shape A, clamping sleeve / stud
Accessories
Stop Cocks DIN 16 2 6 1 - 1 6 263
Application:
When installing pressure measuring instruments, it is advisab-
le to fit a stop cock between measuring instrument and pipe.
You can use stop cocks for measurement of liquids, gases
and vapors with a set-up of measuring instruments which have
a permissible service excess pressure of PN 25 and a
permissible service temperature of 50°C.
Use stop valves at higher pressure and temperature.
Structural shape:
Siphon U-shape DIN 16 282 shape A
inlet: connection stud DIN 16 282 shape 4 G 1/2 to the right
with clamping sleeve DIN 16 283
outlet: connection stud DIN 16 282 shape 6 G 1/2 to the left
with clamping sleeve DIN 16 283 G 1/2 right-left
dimensions (mm)
order-n° material h h1 I r s D
MZW10-H mild steel
St 3 3 170 130 225 22,5 17 -
stainless
MZW11-H steel 170 130 225 22,5 17 -
1.4571
dimensions (mm)
order-n° material I
h h1 r s D
mild steel
MZW18-H St 33 240 120 - 17 56
-
stainless
MZW19-H steel 240 120 - 17 56
-
1.4571
MZA92 MZA81
overhang
version order-n° [ mm ] material
L=±3
MZA 80 60
aluminium
MZA 81 100
DIN 1 6 2 8 1 MZA 82 160
shape A MZA 83 60
stainless
MZA 84 100
steel 1 . 4 5 7 1
MZA 85 160
Throttle devices
protect pressure gauges against pressure hammers and pulsa-
tion of the medium. They are adjustable and can be adapted to
the relevant service conditions.
Connecting pieces
are used to install pressure gauges, stop cocks, stop valves,
siphons and other accessory components.
MZA 11 MZA 30