Sandvik Mining and Construction

Feeder Speed Pot


z Gives manual control of feeder speed (sonar switched off)

•Wired to Sonar Control Connector in Analog Sensor Loom


•Blue/Yellow Wire: 0.1V = min speed
•5V = max speed

Sandvik Mining and Construction


Motorised Webtec
z Motorised Flow Divider
z Pot gives feedback of rotor location
z Motor Driven by EL9563 CAN Motor
z 12V Motor

Black
+12V across wires: Wire:
valve opens Motor
-12V across wires:
valve closes
Red
Wire:
Motor

Sandvik Mining and Construction


Webtec Motor Pot

z Pot gives feedback on rotor location


9 -Measure voltage from gnd (green wire) to pot output (blue wire)
• 0V = Pot broken – gives error code
• 4.32V = valve fully closed, stop motor
• 0.78V = valve fully open, stop motor
• 0.78 V -> 4.32V = valve in middle, turn motor either direction