Professional Documents
Culture Documents
Title:: HNZ Consult
Title:: HNZ Consult
Title:: HNZ Consult
For area of 2.02 ha, Inlet Flow = 2.02 x 160.00 = 323.20 l/s
0.323 m3/s
0.23472
Table 5.A2 PSD / ha: = 43.80 l/s/ha
Table 5.A3 Inlet Pipe: Prop. Pipe gradient = 1 : 200 n= 0.012 = 564 mm dia.
Assumed velocity = 1.50 m/s Q = 0.40 m3/s design ok
D= 0.56 m
A= 0.25 m2
R, (full flow condition) = 0.14 m
Table 5.A4 Outlet Pipe: Prop. Pipe gradient = 1 : 200 n= 0.012 = 350 mm dia.
Assumed velocity = 1.50 m/s Q = 0.11 m3/s design ok
D= 0.35 m
A= 0.10 m2
R, (full flow condition) = 0.09 m
Table 5.A4 Inlet Pipe: (with Inlet Flow of 0.323 m3/s ) = 564 mm dia.
Table 5.A4 Oulet pipe: (with PSD of 0.088 m3/s ) = 350 mm dia.
PSD: (Which is smaller from Table 5.A1 and 5.A2) = 88.48 l/s
Inlet Pipe: (whichever is smaller from Table 5.A3 and 5.A4) = 564 mm dia.
Outlet Pipe: (whichever is smaller from Table 5.A3 and 5.A4) = 350 mm dia.
19878.66284