FA 0 SCADA+ PLC Architecture (Rev. D in Work) PDF
FA 0 SCADA+ PLC Architecture (Rev. D in Work) PDF
99233-2076
Power Plants
(PDS: 0)
Rev. Written Checked Released Release date Status/Edition Issued for Remarks
Commitment/
D N. Gaikwad T. Herzog T. Herzog 28.04.2015 Third ..........
Agreement
C N. Gaikwad T. Herzog T. Herzog 23.01.2015 Second Comment ..........
B T. Herzog R. Meier
T. Herzog 18.06.2014 First Inquiry ..........
H.
A T.T.Win R.Braunmüller 06.05.2013 Preliminary Clarification ..........
Berchtenbreiter
0 R.Braunmüller P.Bulbule 26.03.2012 Preliminary Clarification ..........
Remarks
Several units
*
l Only on last ET200M
n Number depending on plant design
o Optional
g Not applicable for pure gas operation
Connections
Copper Profibus
Copper Profibus (primary ring)
Copper Profibus (secondary ring)
Copper Ethernet
Copper hardwired
Fibre Optic Ethernet
Fibre Optic Profibus (primary ring)
Fibre Optic Profibus (secondary ring)
CAN-Bus
MODBUS
RS 422 (RK512)
RS 232
Geographical stripline
Hardwired connections (Control, Power)
Control Room
Laser Laser
Printer Printer
Switch
UPS 1
CCP 1.1
GCP1
GCP2
GCP3
GIP1
GIP2
GIP3
to PLC Architecture
SCADA Architecture
MAN Scope of Supply: CCP1.1
- CCP G HV - Substation
- HVIP
Control
Bus
MMU MMU
*
*
Prot. MODBUS
MMU
Relay
+00CBA01
+00CBB01
HVIP
HV Substation
CCP
CPU
S7-400
RJ45 RJ45 RJ45
PS
443-1
Panel
CP
PC 677B * Marshalling Kiosks
ET200-M
Control +
X1 X2
RJ45
I/O
I/O
I/O
I/O
IM
341
CP
Protection Panels
* IEC 60870-5-101
ET200-M
OLM
I/O
I/O
I/O
I/O
IM
341
I
CP
RTU
o
Control Room to/from TCP
Dispatch
PLC Architecture Center
K
to/from FFCP
E
PLC Architecture
MV / LV Room
MV Swgr
NE Swgr
+00BAU0x
+00BBA0x
- LV Main Distribution
- UPS
A - DC-System
- BSD
to/from - MCDP
GCP PLC
Architecture
to/from BCP
PLC Architecture
D
+00CDE01
MMU MMU
+00CDD01
CAPP
CAP
* *
ET200-M
ET200-M
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
IM
IM
OLM OLM
SCADA Architecture
Next Previous o
GIP1 CCP GCP1 GIPn FFCP GCPn
GCP GCP
G E G E
Control
to/from CCP PLC Control
to/from CCP PLC
Bus Architecture Bus Architecture
A A
+nnCDA01
+01CDA01
GCP n
GCP 1
CPU
CPU
S7-400
S7-400
RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45
PS
PS
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
443-1
443-1
443-1
443-1
Panel Panel
CP
CP
CP
CP
o
X1 X2
RJ45 RJ45 PC L 1 to n X1 X2
RJ45 RJ45 PC L o
OLM
RJ45 RJ45
NET
Scalance Relay MMU NET
Scalance Relay MMU
B B
Unit Bus
Control Room
Unit Bus
Architecture
Architecture
Engine Hall
SACOS One n
SACOS One 1
+nnCDD01
+01CDD01
EDS-D EDS-D
GIP n
1 to n
GIP 1
ET200-M
Genset 1 Genset n
I/O
I/O
I/O
I/O
I/O
IM
OLM
*
ET200-M
Gensets,
I/O
I/O
I/O
I/O
I/O
IM
RJ45 outlet
RJ45 outlet
RJ45 RJ45
GWM
SACOS, GWM
GIP´s
1 to n
+01CDC01
+nnCDC01
EAP 1
EAP n
MMU EAPs MMU
Engine 1 Engine n
* Auxiliaries * Auxiliaries
ET200-M
ET200-M
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
IM
IM
OLM OLM
Outside
+01CDG01
+nnCDG01
ERP 1
ERP n
1 to n
Engine
MAN Scope of Supply:
Engine 1 Radiator Fans Engine n - GCP 1 / 2 / 3
Radiator Fans Radiator Fans - GIP 1 / 2 / 3
- SACOS ONE 1 / 2 / 3
PS1
PS2
RJ45 RJ45 RJ45 RJ45
RJ45 RJ45 RJ45 RJ45 SCALANCE
X208
CPU
RJ45
S7-300
PN/DP
PS
315-2
CP
X1 X2
RJ45 RJ45 RJ45
HMI
SIEMENS
+00CJF01
BCP-C
TP900
RJ45 RJ45
PROFINET
SWD
MP DP
GATEWAY
L-, P-Control 1
socket outlet
IM 360
I/O
I/O
I/O
I/O
Control Room
IM
IM
B
OLM
to/from GCP PLC
Architecture
to/from CCP PLC C
Architecture
Engine Hall
Common Boiler
Auxiliaries
...
(Pumps etc.)
OLM
+00CJA01
ET200-M
Steam Turbine Genset
+00CJJ01
I/O
I/O
I/O
I/O
I/O
IM
BAT 1
GCP
Battery + Battery
TCP
Control Panel
Charger for ELECTRONIC
Steam Turbine GOVERNOR
505 Prot. Syn.
Relay Unit
+00CJK01
Engine Hall
+00CJL01
Steam
TAP
Steam Turbine
TGP
Turbine Steam Turbine
Auxiliary Panel Gauge Panel
(Customer)
Steam Turbine
Auxiliaries