Enforcer: Installation Manual
Enforcer: Installation Manual
Installation Manual
ENFORCER
®
CHECKING THE STATUS OF SENSORS
The "TEST" mode can be used to check the current status of both sensors during
installation. Press the "MODE" button and select the "TEST" mode. The status of both
sensors will be simultaneously shown on the LCD. E-920B
a. S1-O: Indicates the relay contact of sensor #1 is "OPEN".
Voice Dialer
b. S1-C: Indicates the relay contact of sensor #1 is "CLOSED".
Summary: The E-920B Voice Dialer
c. S2-O: Indicates the relay contact of sensor #2 is "OPEN".
will automatically dial up to four
d. S2-C: Indicates the relay contact of sensor #2 is "CLOSED". telephone numbers and deliver one
of two different messages when
triggered by an alarm system.
HOW IT WORKS
TESTING THE UNIT — DIALING OUT TO THE PROGRAMMED
When triggered by an alarm system, the If within 8 to 10 rings there is no
NUMBERS E-920B Voice Dialer can dial up to four connection, the E-920B will automatically
Note: To ensure proper operation, the E-920B must be tested at least once in the telephone numbers and/or pager numbers. dial the next programmed number.
OPERATE mode, and the dialer must be connected to the phone line. Each number can contain up to 32 digits
If the dialer has attempted to dial each
(including pound (#) tones and pauses
1. Contact the company or person who 7. Trigger input #1 or #2 to simulate an number one time and the unit is still in the
used in pager numbers).
will be called by each of the recorded alarm condition. alarm state, the dialer will attempt to call
telephone numbers prior to performing When the dialer is activated, the LCD will all numbers a second time. All busy
8. At this point the dialer should begin show the numbers dialed at each step of numbers will be dialed a third time.
an actual test in the "OPERATE" mode. to dial the telephone numbers #1 to
Advise the people at the numbers the dialing process. When the dialer
#4. The outgoing message (1 or 2, Note: If the dialer is programmed to call
dialed that you are conducting a test, makes a connection, one of two possible
depending on which trigger is a voice pager service which requires
and ask them to confirm with you that 16-sec. voice messages will be delivered.
tripped) will be delivered for one operator assistance, the service should
the message was received and The user can record each message to
minute once the dialer makes a be notified in advance regarding the
understood. respond to one or two inputs. Each
connection. meaning of the message.
message is then delivered repeatedly for
2. Turn the power "OFF". Note: The message will not be heard one minute to ensure the full message is
3. Connect the dialer to the phone line because the test is just a controlled received. This process will repeat for each
(see page 3). alarm event. number stored.
4. The sensor should not be in the alarm 9. The message will repeat for #2, #3
mode. If it is, the unit will start dialing and #4 telephone numbers. If a WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship
while used in normal service for a period of one (1) year from the date of sale to the original consumer customer.
immediately. number is busy or unanswered after
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
8 to 10 rings, that number will be
5. Turn the power "ON". transportation prepaid, to SECO-LARM.
skipped, and dialed again once the This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse,
6. Use the "MODE" button to place the other numbers have finished dialing. neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason
unit in the "OPERATE" mode. Numbers that are still busy will be SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects
dialed a third and final time. in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or
repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral,
Note: Prior to operation of the E-920B, be sure the power source is correct and the incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
wiring is connected properly. It is recommended that the E-920B be tested under
simulated alarm conditions and that the user receive confirmation of transmission MiE920B_0910.pmd PIKVR1
SECO-LARM® U.S.A., Inc.
from the numbers dialed. Website: www.seco-larm.com
16842 Millikan Avenue, Irvine, CA 92606 E-mail: sales@seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 8 SECO-LARM U.S.A., Inc. Page 1
VOICE DIALER Installation Manual VOICE DIALER Installation Manual
TABLE OF CONTENTS Note: The telephone numbers can be programmed in any order, and skipped as
needed. Whenever a new telephone number is programmed, it will completely
How It Works ........................................... 1 Recording Messages ................................ 6 erase and replace old telephone numbers previously stored in that location.
E-920B Overview ...................................... 2 Erasing Memory ....................................... 6
Wiring Diagram ......................................... 3 Storing Pager Numbers & Access Codes 6 Example 1: Store pager number 585-8525 and numeric message 119 as telephone #3.
Connecting the E-920B ............................ 3 Specifications ........................................... 7 Press: 5 8 5 8 5 2 5, "MEMORY" (hold two sec.), 1 1 9, "MEMORY" (momentarily), 3
Setting the DIP Switches .......................... 4 Checking the Status of Sensors ............... 8
Example 2: Store pager number 585-8525 with access code 3 (if required) and numeric
Storing Telephone Numbers ..................... 5 Testing the Unit — Operate Mode ............ 8 message 119 as telephone #4.
RECORDING OUTGOING VOICE MESSAGE(S) WIRING DIAGRAM RED (+12VDC ONLY) (optional)
The E-920B can play back one of two 4. To record, press and hold the "VOICE" 2.1x5.5x9 mm A BLACK (common (-) ground, must connect)
outgoing messages of up to 16 seconds button. The word "VOICE" will appear 12VDC center YELLOW (trigger 1, message 1) NO/NC* (GND)
each: on the LCD during recording. The positive plug 12VDC
adapter GREEN (trigger 2, message 2) NO/NC* (GND)
• Message one is played when input #1 "VOICE" button must be held down for
the entire time of the recording. *Based on DIP switch
(yellow wire) is triggered. (not included)
See page 4, Sections 5 & 6
• Message two is played when input #2 5. As soon as the voice key is released
(green wire) is triggered. or when 16 secs. have passed, the
word "VOICE" will disappear from the RED
To ensure the message is received, each Telephone line
LCD. This indicates that the message (must connect when
message is repeated for one minute. GREEN
is stored. testing dialer)
Both outgoing messages should be
6. If you wish to change either outgoing Note: If the red B
(not included)
timed and practiced prior to recording. wire is connected Siren output jack. OPTIONAL
9VDC
message, repeat steps 1 through 5.
To record the outgoing voice message(s): The previous message will be to the alarm 2.5mm mono jack. ACCESSORIES
control panel's Transistor ground A. 12VDC adapter
1. Locate the microphone in the lower replaced when the new message is
+12VDC output, output 180mA B. 9VDC standby battery
right corner of the keypad area. When recorded. the adapter is maximum.
recording a message, speak in a 7. Once recorded, review the voice optional.
normal voice about 7 inches from the message simply by pressing the
microphone. "VOICE" button. The first message will
play. Pressing "VOICE" again will play
CONNECTING THE E-920B
2. Place the unit in the "PROGRAM" mode
by pressing the "MODE" button. the second message. To review at Note: You can program telephone c. For more reliable power, connect
3. Press key "1" to specify the first voice other times, first press the "MODE" numbers and voice messages prior to both the red wire and a 12VDC
message, or press key "2" to specify button until "PROGRAM" shows on the connecting power as long as the 9VDC adapter (not included). For backup
the second message. LCD. Pressing "VOICE" will alternately battery is installed. The standby battery power, also install a 9VDC battery
replay message one and two. will allow for about 24 hours of (not included).
operation.
TO COMPLETELY ERASE NUMBERS STORED IN MEMORY 3. The two inputs can be connected to two
1. Press the "MODE" button to set the 3. When the LCD indicates telephone Note: The E-920B uses an EEPROM to separate alarm control panel outputs.
dialer to "PROGRAM" mode. numbers, press "#". retain memory in the event of a power Each input triggers a specific voice
loss. message. The yellow wire (input #1) is
2. Press the "MEMORY" button. 4. Test the unit once again. (see pg. 8)
1. Select a location for the dialer that is for the first voice message, and the
near both an AC outlet and the alarm green wire (input #2) is for the second
TO STORE A PAGER NUMBER AND/OR NUMERIC CODE voice message. The messages should
control panel. Keep the E-920B out of
1. Press the "MODE" button to set the 4. Input the numeric code desired for the reflect the type of emergency which the
sight.
dialer to "PROGRAM" mode. pager directly after the pause (this alarm's output represents. The green
2. Enter the pager number to be dialed number will appear on the pager unit). 2. Connect to power: and yellow wires should be connected
including any area code if necessary. Input a "#" at the end of the message if a. If the dialer is powered from the alarm to separate NO or NC outputs of the
Check to see that the correct number required by the pager service (may not control panel, connect the red, black, alarm.
is displayed by the LCD. be necessary). yellow, and green wires of the 4-pin 4. The dialer can be connected to a pulse
3. Press and hold the "MEMORY" button 5. Momentarily press the "MEMORY" connector to the panel as shown in or touch-tone phone line using the
for about two seconds. A "dash" will button and then the "1" key. The pager the wiring diagram. included telephone cable.
appear on the LCD to indicate that the number and numeric code will be
b. If using an optional 12VDC adapter, it 5. Once all connections have been made,
dialer will pause approx. five secs., to stored as telephone #1.
is not necessary to connect the red the unit is ready to be programmed.
allow the pager time to respond. 6. Repeat for telephone #2, #3, and #4 if wire of the 4-pin connector to the
Note: Pauses and "#" keys count as needed. alarm control panel. However, the
one digit. Each number stored can black, yellow, and green wires MUST
contain up to 32 digits. be connected.
Page 6 SECO-LARM U.S.A., Inc. Page 3
VOICE DIALER Installation Manual VOICE DIALER Installation Manual