MÔ HÌNH ETABS HẦM 2

BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (6) 100 60 3 57.0 8.0 0.013 0.994 5.70 0.10% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 1.0 0.002 0.999 5.70 0.10% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 28.0 0.044 0.977 13.77 0.24% 6D20+3D20 28.27 0.50% OK
H1, H2 MB-1 NhÞp 100 60 3 57.0 26.0 0.041 0.979 12.76 0.22% 6D20+1D20 21.99 0.39% OK
Gèi (7) 100 60 3 57.0 33.0 0.052 0.973 16.30 0.29% 6D20+2D20 25.13 0.44% OK
NhÞp 100 60 3 57.0 13.0 0.021 0.990 6.31 0.11% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 2.0 0.003 0.998 5.70 0.10% 6D20+3D20 28.27 0.50% OK
Gèi (*) 60 60 3 57.0 1.0 0.003 0.999 3.42 0.10% 4D18 10.18 0.30% OK
NhÞp 60 60 3 57.0 1.0 0.003 0.999 3.42 0.10% 4D18 10.18 0.30% OK
Gèi (*) 60 60 3 57.0 43.0 0.113 0.940 21.99 0.64% 4D18+5D18 22.90 0.67% OK
H1, H2 MB-12 NhÞp 60 60 3 57.0 26.0 0.068 0.965 12.96 0.38% 4D18+3D18 17.81 0.52% OK
Gèi (*) 60 60 3 57.0 41.0 0.108 0.943 20.90 0.61% 4D18+5D18 22.90 0.67% OK
NhÞp 60 60 3 57.0 1.0 0.003 0.999 3.42 0.10% 4D18 10.18 0.30% OK
Gèi (*) 60 60 3 57.0 1.0 0.003 0.999 3.42 0.10% 4D18 10.18 0.30% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (*) 60 60 3 57.0 8.0 0.021 0.989 3.89 0.11% 4D20+2D20 18.85 0.55% OK
NhÞp 60 60 3 57.0 9.0 0.024 0.988 4.38 0.13% 4D18 10.18 0.30% OK
Gèi (A) 60 60 3 57.0 14.0 0.037 0.981 6.86 0.20% 4D20 12.57 0.37% OK
NhÞp 60 60 3 57.0 11.0 0.029 0.985 5.37 0.16% 4D18 10.18 0.30% OK
Gèi (B) 60 60 3 57.0 22.0 0.058 0.970 10.90 0.32% 4D20+6D20 31.42 0.92% OK
NhÞp 60 60 3 57.0 18.0 0.047 0.976 8.87 0.26% 4D18+2D20 16.46 0.48% OK
Gèi (C) 60 60 3 57.0 30.0 0.079 0.959 15.04 0.44% 4D20+6D20 31.42 0.92% OK
NhÞp 60 60 3 57.0 24.0 0.063 0.967 11.92 0.35% 4D18+3D20 19.60 0.57% OK
H1, H2 MB-10 Gèi (D) 60 60 3 57.0 29.0 0.076 0.960 14.52 0.42% 4D20+6D20 31.42 0.92% OK
NhÞp 60 60 3 57.0 23.0 0.061 0.969 11.41 0.33% 4D18+3D20 19.60 0.57% OK
Gèi (E) 60 60 3 57.0 29.0 0.076 0.960 14.52 0.42% 4D20+6D20 31.42 0.92% OK
NhÞp 60 60 3 57.0 19.0 0.050 0.974 9.37 0.27% 4D18+2D20 16.46 0.48% OK
Gèi (F) 60 60 3 57.0 21.0 0.055 0.972 10.39 0.30% 4D20+6D20 31.42 0.92% OK
NhÞp 60 60 3 57.0 11.0 0.029 0.985 5.37 0.16% 4D18 10.18 0.30% OK
Gèi (G) 60 60 3 57.0 17.0 0.045 0.977 8.36 0.24% 4D20+2D20 18.85 0.55% OK
NhÞp 60 60 3 57.0 13.0 0.034 0.983 6.36 0.19% 4D18+2D18 15.27 0.45% OK
Gèi (*) 60 60 3 57.0 11.0 0.029 0.985 5.37 0.16% 4D20+6D20 31.42 0.92% OK
Gèi (*) 60 60 3 57.0 15.0 0.039 0.980 7.36 0.22% 4D18 10.18 0.30% OK
H1, H2 MB-13 NhÞp 60 60 3 57.0 12.0 0.032 0.984 5.86 0.17% 4D18 10.18 0.30% OK
Gèi (*) 60 60 3 57.0 10.0 0.026 0.987 4.87 0.14% 4D18+2D18 15.27 0.45% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (*) 60 60 3 57.0 8.0 0.021 0.989 3.89 0.11% 4D25+1D22 23.44 0.69% OK
NhÞp 60 60 3 57.0 10.0 0.026 0.987 4.87 0.14% 4D22 15.21 0.44% OK
Gèi (A) 60 60 3 57.0 12.0 0.032 0.984 5.86 0.17% 4D25 19.63 0.57% OK
NhÞp 60 60 3 57.0 10.0 0.026 0.987 4.87 0.14% 4D22 15.21 0.44% OK
Gèi (B) 60 60 3 57.0 28.0 0.074 0.962 13.99 0.41% 4D25+2D25 29.45 0.86% OK
NhÞp 60 60 3 57.0 21.0 0.055 0.972 10.39 0.30% 4D22+2D22 22.81 0.67% OK
Gèi (C) 60 60 3 57.0 28.0 0.074 0.962 13.99 0.41% 4D25+4D25 39.27 1.15% OK
NhÞp 60 60 3 57.0 16.0 0.042 0.978 7.86 0.23% 4D22+3D22 26.61 0.78% OK
H1, H2 MB-11 Gèi (D) 60 60 3 57.0 22.0 0.058 0.970 10.90 0.32% 4D25+4D25 39.27 1.15% OK
NhÞp 60 60 3 57.0 15.0 0.039 0.980 7.36 0.22% 4D22+3D22 26.61 0.78% OK
Gèi (E) 60 60 3 57.0 28.0 0.074 0.962 13.99 0.41% 4D25+9D25 63.81 1.87% OK
NhÞp 60 60 3 57.0 21.0 0.055 0.972 10.39 0.30% 4D22+8D25 54.48 1.59% OK
Gèi (F) 60 60 3 57.0 29.0 0.076 0.960 14.52 0.42% 4D25+9D25 63.81 1.87% OK
NhÞp 60 60 3 57.0 13.0 0.034 0.983 6.36 0.19% 4D22+3D22 26.61 0.78% OK
Gèi (G) 60 60 3 57.0 21.0 0.055 0.972 10.39 0.30% 4D25+6D25 49.09 1.44% OK
NhÞp 60 60 3 57.0 17.0 0.045 0.977 8.36 0.24% 4D22+5D25 39.75 1.16% OK
Gèi (*) 60 60 3 57.0 12.0 0.032 0.984 5.86 0.17% 4D25+9D25 63.81 1.87% OK
Gèi (*) 60 60 3 57.0 26.0 0.068 0.965 12.96 0.38% 4D18+3D18 17.81 0.52% OK
H1, H2 MB-12A NhÞp 60 60 3 57.0 20.0 0.053 0.973 9.88 0.29% 4D18+2D18 15.27 0.45% OK
Gèi (*) 60 60 3 57.0 22.0 0.058 0.970 10.90 0.32% 4D18+3D18 17.81 0.52% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (B1) 80 60 3 57.0 8.0
68.0 0.134 0.928 35.23 0.77% 6D25+2D20 35.74 0.78% OK
NhÞp 80 60 3 57.0 50.0 0.099 0.948 25.35 0.56% 6D20+5D25 43.39 0.95% OK
Gèi (D) 80 60 3 57.0 86.0 0.170 0.906 45.60 1.00% 9D25+8D25 83.45 1.83% OK
NhÞp 80 60 3 57.0 48.0 0.095 0.950 24.28 0.53% 6D20+5D25 43.39 0.95% OK
H1, H2 MB-14 Gèi (E1) 80 60 3 57.0 83.0 0.164 0.910 43.84 0.96% 9D25+7D25 78.54 1.72% OK
NhÞp 80 60 3 57.0 45.0 0.089 0.953 22.69 0.50% 6D20+3D25 33.58 0.74% OK
Gèi (G) 80 60 3 57.0 58.0 0.114 0.939 29.69 0.65% 6D20+4D25 38.48 0.84% OK
NhÞp 80 60 3 57.0 13.0 0.026 0.987 6.33 0.14% 6D20 18.85 0.41% OK
Gèi (*) 80 60 3 57.0 10.0 0.020 0.990 4.85 0.11% 6D25 29.45 0.65% OK
Gèi (B1) 80 60 3 57.0 57.0 0.112 0.940 29.14 0.64% 6D25 29.45 0.65% OK
NhÞp 80 60 3 57.0 42.0 0.083 0.957 21.10 0.46% 6D20+4D25 38.48 0.84% OK
H1, H2 MB-15 Gèi (D) 80 60 3 57.0 73.0 0.144 0.922 38.06 0.83% 9D25+6D25 73.63 1.61% OK
NhÞp 80 60 3 57.0 42.0 0.083 0.957 21.10 0.46% 6D20+4D25 38.48 0.84% OK
Gèi (E1) 80 60 3 57.0 57.0 0.112 0.940 29.14 0.64% 6D25 29.45 0.65% OK
Gèi (*) 40 60 3 57.0 14.0 0.055 0.972 6.93 0.30% 4D20+2D20 18.85 0.83% OK
NhÞp 40 60 3 57.0 4.0 0.016 0.992 2.28 0.10% 4D18 10.18 0.45% OK
Gèi (F) 40 60 3 57.0 12.0 0.047 0.976 5.91 0.26% 4D20 12.57 0.55% OK
H1, H2 MB-15A NhÞp 40 60 3 57.0 8.0 0.032 0.984 3.91 0.17% 4D18 10.18 0.45% OK
Gèi (G) 40 60 3 57.0 16.0 0.063 0.967 7.95 0.35% 4D20 12.57 0.55% OK
NhÞp 40 60 3 57.0 11.0 0.043 0.978 5.41 0.24% 4D20 12.57 0.55% OK
Gèi (*) 40 60 3 57.0 9.0 0.036 0.982 4.41 0.19% 4D20+3D20 21.99 0.96% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (*) 60 60 3 57.0 8.0
30.0 0.079 0.959 15.04 0.44% 4D20+4D20 25.13 0.73% OK
H1, H2 MB-1A NhÞp 60 60 3 57.0 27.0 0.071 0.963 13.47 0.39% 4D20+3D20 21.99 0.64% OK
Gèi (5) 60 60 3 57.0 30.0 0.079 0.959 15.04 0.44% 4D20+4D20 25.13 0.73% OK
Gèi (*) 40 60 3 57.0 8.0 0.032 0.984 3.91 0.17% 4D20+2D18 17.66 0.77% OK
NhÞp 40 60 3 57.0 7.0 0.028 0.986 3.41 0.15% 4D18 10.18 0.45% OK
Gèi (A) 40 60 3 57.0 15.0 0.059 0.969 7.44 0.33% 4D20 12.57 0.55% OK
H1, H2 MB-15B NhÞp 40 60 3 57.0 14.0 0.055 0.972 6.93 0.30% 4D18 10.18 0.45% OK
Gèi (*) 40 60 3 57.0 16.0 0.063 0.967 7.95 0.35% 4D20 12.57 0.55% OK
NhÞp 40 60 3 57.0 6.0 0.024 0.988 2.92 0.13% 4D18 10.18 0.45% OK
Gèi (G) 40 60 3 57.0 18.0 0.071 0.963 8.98 0.39% 4D20+2D18 17.66 0.77% OK
Gèi (6) 100 60 3 57.0 24.0 0.038 0.981 11.76 0.21% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 8.0 0.013 0.994 5.70 0.10% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 34.0 0.054 0.972 16.81 0.29% 6D20+6D20 37.70 0.66% OK
H1, H2 MB-2 NhÞp 100 60 3 57.0 30.0 0.047 0.976 14.78 0.26% 6D20 18.85 0.33% OK
Gèi (7) 100 60 3 57.0 38.0 0.060 0.969 18.85 0.33% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 12.0 0.019 0.990 5.82 0.10% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 5.0 0.008 0.996 5.70 0.10% 6D20+3D20 28.27 0.50% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (*) 80 60 3 57.0 8.0
6.0 0.012 0.994 4.56 0.10% 6D20 18.85 0.41% OK
NhÞp 80 60 3 57.0 8.0 0.016 0.992 4.56 0.10% 6D20 18.85 0.41% OK
Gèi (A) 80 60 3 57.0 50.0 0.099 0.948 25.35 0.56% 6D20+3D25 33.58 0.74% OK
NhÞp 80 60 3 57.0 22.0 0.043 0.978 10.81 0.24% 6D20+2D20 25.13 0.55% OK
Gèi (B1) 80 60 3 57.0 54.0 0.107 0.944 27.51 0.60% 6D20+6D25 48.30 1.06% OK
NhÞp 80 60 3 57.0 33.0 0.065 0.966 16.41 0.36% 6D20+3D20 28.27 0.62% OK
H1, H2 MB-16 Gèi (D) 80 60 3 57.0 61.0 0.120 0.936 31.34 0.69% 6D20+6D25 48.30 1.06% OK
NhÞp 80 60 3 57.0 32.0 0.063 0.967 15.90 0.35% 6D20+3D20 28.27 0.62% OK
Gèi (E1) 80 60 3 57.0 61.0 0.120 0.936 31.34 0.69% 6D20+6D25 48.30 1.06% OK
NhÞp 80 60 3 57.0 22.0 0.043 0.978 10.81 0.24% 6D20+2D20 25.13 0.55% OK
Gèi (G) 80 60 3 57.0 51.0 0.101 0.947 25.89 0.57% 6D20+4D25 38.48 0.84% OK
NhÞp 80 60 3 57.0 14.0 0.028 0.986 6.82 0.15% 6D20 18.85 0.41% OK
Gèi (*) 80 60 3 57.0 3.0 0.006 0.997 4.56 0.10% 6D20+4D25 38.48 0.84% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (2) 100 60 3 57.0 8.0
22.0 0.035 0.982 10.76 0.19% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 8.0 0.013 0.994 5.70 0.10% 6D20 18.85 0.33% OK
Gèi (3) 100 60 3 57.0 22.0 0.035 0.982 10.76 0.19% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 47.0 0.074 0.961 23.50 0.41% 6D20+2D20 25.13 0.44% OK
Gèi (4) 100 60 3 57.0 89.0 0.140 0.924 46.30 0.81% 6D20+7D25 53.21 0.93% OK
NhÞp 100 60 3 57.0 15.0 0.024 0.988 7.30 0.13% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 13.0 0.021 0.990 6.31 0.11% 6D20+3D20 28.27 0.50% OK
H1, H2 MB-3 NhÞp 100 60 3 57.0 11.0 0.017 0.991 5.70 0.10% 6D20 18.85 0.33% OK
Gèi (5) 100 60 3 57.0 25.0 0.039 0.980 12.26 0.22% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 8.0 0.013 0.994 5.70 0.10% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 31.0 0.049 0.975 15.28 0.27% 6D20+3D20 28.27 0.50% OK
NhÞp 100 60 3 57.0 29.0 0.046 0.977 14.27 0.25% 6D20 18.85 0.33% OK
Gèi (7) 100 60 3 57.0 38.0 0.060 0.969 18.85 0.33% 6D20 18.85 0.33% OK
NhÞp 100 60 3 57.0 11.4 0.018 0.991 5.70 0.10% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 1.0 0.002 0.999 5.70 0.10% 6D20+3D20 28.27 0.50% OK
Gèi (*) 100 60 3 57.0 8.0 0.013 0.994 5.70 0.10% 8D25+9D25 83.45 1.46% OK
NhÞp 100 60 3 57.0 14.0 0.022 0.989 6.81 0.12% 6D25+4D25 49.09 0.86% OK
Gèi (2) 100 60 3 57.0 18.5 0.029 0.985 9.03 0.16% 6D25+5D25 54.00 0.95% OK
H1, H2 MB-4 NhÞp 100 60 3 57.0 13.2 0.021 0.989 6.42 0.11% 6D25 29.45 0.52% OK
Gèi (3) 100 60 3 57.0 20.0 0.032 0.984 9.77 0.17% 6D25+6D25 58.90 1.03% OK
NhÞp 100 60 3 57.0 44.0 0.069 0.964 21.94 0.38% 6D25+4D25 49.09 0.86% OK
Gèi (4) 100 60 3 57.0 55.0 0.087 0.955 27.70 0.49% 6D25+5D25 54.00 0.95% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (3) 100 60 3 57.0 8.0
82.0 0.129 0.930 42.36 0.74% 6D25+6D25 58.90 1.03% OK
H1, H2 MB-4A NhÞp 100 60 3 57.0 45.0 0.071 0.963 22.46 0.39% 6D20+4D20 31.42 0.55% OK
Gèi (4) 100 60 3 57.0 77.0 0.122 0.935 39.58 0.69% 6D25+6D25 58.90 1.03% OK
Gèi (3) 100 60 3 57.0 56.0 0.088 0.954 28.22 0.50% 6D20+6D20 37.70 0.66% OK
H1, H2 MB-5 NhÞp 100 60 3 57.0 48.0 0.076 0.961 24.02 0.42% 6D20+6D20 37.70 0.66% OK
Gèi (4) 100 60 3 57.0 93.0 0.147 0.920 48.57 0.85% 6D20+7D25 53.21 0.93% OK
Gèi (*) 60 60 3 57.0 1.0 0.003 0.999 3.42 0.10% 4D20+4D20 25.13 0.73% OK
NhÞp 60 60 3 57.0 7.0 0.018 0.991 3.42 0.10% 4D20 12.57 0.37% OK
H1, H2 MB-6 Gèi (2) 60 60 3 57.0 18.0 0.047 0.976 8.87 0.26% 4D20 12.57 0.37% OK
NhÞp 60 60 3 57.0 14.0 0.037 0.981 6.86 0.20% 4D20 12.57 0.37% OK
Gèi (3) 60 60 3 57.0 17.0 0.045 0.977 8.36 0.24% 4D20+4D20 25.13 0.73% OK
Gèi (*) 60 60 3 57.0 1.0 0.003 0.999 3.42 0.10% 4D20+4D20 25.13 0.73% OK
NhÞp 60 60 3 57.0 8.0 0.021 0.989 3.89 0.11% 4D20 12.57 0.37% OK
H1, H2 MB-6A Gèi (2) 60 60 3 57.0 19.0 0.050 0.974 9.37 0.27% 4D25+3D25 34.36 1.00% OK
NhÞp 60 60 3 57.0 15.0 0.039 0.980 7.36 0.22% 4D20 12.57 0.37% OK
Gèi (3) 60 60 3 57.0 17.0 0.045 0.977 8.36 0.24% 4D25 19.63 0.57% OK
Gèi (B1) 100 60 3 57.0 85.0 0.134 0.928 44.04 0.77% 6D25+13D25 93.27 1.64% OK
NhÞp 100 60 3 57.0 54.0 0.085 0.955 27.17 0.48% 6D25+4D25 49.09 0.86% OK
H1, H2 MB-8 Gèi (D) 100 60 3 57.0 88.0 0.139 0.925 45.73 0.80% 6D25+13D25 93.27 1.64% OK
NhÞp 100 60 3 57.0 53.0 0.084 0.956 26.64 0.47% 6D25+4D25 49.09 0.86% OK
Gèi (E1) 100 60 3 57.0 88.0 0.139 0.925 45.73 0.80% 6D25+13D25 93.27 1.64% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (B1) 100 60 3 57.0 8.0
72.0 0.114 0.940 36.83 0.65% 6D25+8D25 68.72 1.21% OK
NhÞp 100 60 3 57.0 46.0 0.073 0.962 22.98 0.40% 6D20+6D20 37.70 0.66% OK
Gèi (D) 100 60 3 57.0 71.0 0.112 0.940 36.29 0.64% 6D25+6D25 58.90 1.03% OK
NhÞp 100 60 3 57.0 45.0 0.071 0.963 22.46 0.39% 6D20+6D20 37.70 0.66% OK
H1, H2 MB-7 Gèi (E1) 100 60 3 57.0 69.0 0.109 0.942 35.20 0.62% 6D25+7D25 63.81 1.12% OK
NhÞp 100 60 3 57.0 45.0 0.071 0.963 22.46 0.39% 6D20+5D20 34.56 0.61% OK
Gèi (G) 100 60 3 57.0 69.0 0.109 0.942 35.20 0.62% 6D25+4D25 49.09 0.86% OK
NhÞp 100 60 3 57.0 18.0 0.028 0.986 8.78 0.15% 6D20 18.85 0.33% OK
Gèi (*) 100 60 3 57.0 16.0 0.025 0.987 7.79 0.14% 6D25 29.45 0.52% OK
Gèi (A) 100 60 3 57.0 72.0 0.114 0.940 36.83 0.65% 6D25+4D25 49.09 0.86% OK
H1, H2 MB-8A NhÞp 100 60 3 57.0 44.0 0.069 0.964 21.94 0.38% 6D20+5D20 34.56 0.61% OK
Gèi (B1) 100 60 3 57.0 81.0 0.128 0.931 41.80 0.73% 6D25+6D25 58.90 1.03% OK
Gèi (F) 40 60 3 57.0 1.0 0.004 0.998 2.28 0.10% 4D20 12.57 0.55% OK
NhÞp 40 60 3 57.0 8.0 0.032 0.984 3.91 0.17% 4D20 12.57 0.55% OK
H1, H2 SB-11 Gèi (G) 40 60 3 57.0 11.0 0.043 0.978 5.41 0.24% 4D20 12.57 0.55% OK
NhÞp 40 60 3 57.0 7.0 0.028 0.986 3.41 0.15% 4D20 12.57 0.55% OK
Gèi (*) 40 60 3 57.0 13.0 0.051 0.974 6.42 0.28% 4D20+2D25 22.38 0.98% OK
BẢNG TÍNH CỐT THÉP DẦM

Cấp độ bền BT : B35 Rb = 19.5 Cốt thép Ø < 10 CB300-V Rs=Rsc= 280 ξR= 0.552 αR= 0.399
µmin = 0.10% Cốt thép Ø ≥ 10 CB400-V Rs=Rsc= 365 ξR= 0.519 αR= 0.384
Kích thước Tính thép Chọn thép
Momen
Tầng Tên dầm Vị trí b h a h0 AsTT H.lượng D As
CH
H.lượng
αm ζ Kết luận
(cm) (cm) (cm) (cm) (T.m) (cm 2) µTT (%) (mm) (cm 2) µBT (%)
Gèi (E1) 40 60 3 57.0 8.0
10.0 0.039 0.980 4.91 0.22% 4D20+2D25 22.38 0.98% OK
NhÞp 40 60 3 57.0 8.0 0.032 0.984 3.91 0.17% 4D20 12.57 0.55% OK
Gèi (F) 40 60 3 57.0 1.0 0.004 0.998 2.28 0.10% 4D20 12.57 0.55% OK
H1, H2 SB-11A NhÞp 40 60 3 57.0 8.0 0.032 0.984 3.91 0.17% 4D20 12.57 0.55% OK
Gèi (G) 40 60 3 57.0 11.0 0.043 0.978 5.41 0.24% 4D20 12.57 0.55% OK
NhÞp 40 60 3 57.0 7.0 0.028 0.986 3.41 0.15% 4D20 12.57 0.55% OK
Gèi (*) 40 60 3 57.0 13.0 0.051 0.974 6.42 0.28% 4D20+2D25 22.38 0.98% OK
Gèi (*) 60 60 3 57.0 5.0 0.013 0.993 3.42 0.10% 4D18+2D18 15.27 0.45% OK
H1, H2 SB-12 NhÞp 60 60 3 57.0 8.0 0.021 0.989 3.89 0.11% 4D18 10.18 0.30% OK
Gèi (A) 60 60 3 57.0 15.0 0.039 0.980 7.36 0.22% 4D18 10.18 0.30% OK
Gèi (*) 60 60 3 57.0 9.0 0.024 0.988 4.38 0.13% 4D18+2D18 15.27 0.45% OK
H1, H2 SB-13 NhÞp 60 60 3 57.0 5.0 0.013 0.993 3.42 0.10% 4D18 10.18 0.30% OK
Gèi (A) 60 60 3 57.0 3.0 0.008 0.996 3.42 0.10% 4D18 10.18 0.30% OK
Gèi (*) 40 60 3 57.0 11.0 0.043 0.978 5.41 0.24% 4D18+2D18 15.27 0.67% OK
NhÞp 40 60 3 57.0 9.0 0.036 0.982 4.41 0.19% 4D18 10.18 0.45% OK
Gèi (4) 40 60 3 57.0 7.0 0.028 0.986 3.41 0.15% 4D18 10.18 0.45% OK
NhÞp 40 60 3 57.0 4.0 0.016 0.992 2.28 0.10% 4D18 10.18 0.45% OK
Gèi (5) 40 60 3 57.0 8.0 0.032 0.984 3.91 0.17% 4D18+2D18 15.27 0.67% OK
H1, H2 SB-2 NhÞp 40 60 3 57.0 1.0 0.004 0.998 2.28 0.10% 4D18 10.18 0.45% OK
Gèi (6) 40 60 3 57.0 6.0 0.024 0.988 2.92 0.13% 4D18 10.18 0.45% OK
NhÞp 40 60 3 57.0 9.0 0.036 0.982 4.41 0.19% 4D18 10.18 0.45% OK
Gèi (7) 40 60 3 57.0 6.0 0.024 0.988 2.92 0.13% 4D18 10.18 0.45% OK
NhÞp 40 60 3 57.0 1.0 0.004 0.998 2.28 0.10% 4D18 10.18 0.45% OK
Gèi (*) 40 60 3 57.0 17.0 0.067 0.965 8.47 0.37% 4D18+2D22 17.78 0.78% OK
KIỂM TRA CẤU KIỆN THEO SỰ MỞ RỘNG VẾT NỨT

(Theo TCVN 5574-2012)

* Cấu kiện: MB8 (B1-D)-(NHỊP)

1. Số liệu tính toán


- Cấp độ bền bê tông: B35 Eb = 34500 MPa
Rb,ser = 25.5 MPa
β= 1.8
- Nhóm cốt thép: A-III Es = 200000 MPa
α= 5.80
- Kích thước tiết diện b= 100 cm
h= 60 cm
a= 3 cm
a' = 3 cm
ho = 57 cm
h'f = 6 cm ( = 2a')
- Diện tích cốt thép thiết kế: As = 49.09 cm2
A's = 29.45 cm2
µ= 0.008
- Mô men do tải trọng thường xuyên: Mtx = 49.0 Tm
- Mô men do tải trọng tạm thời dài hạn: Mdh = 4.6 Tm
- Mô men do tải trọng tạm thời ngắn hạn: Mnh = 10.8 Tm
- Giá trị giới hạn của bề rộng vết nứt [acrc1] = 0.4 mm
[acrc2] = 0.3 mm
2. Kiểm tra bề rộng vết nứt
σs
acrc = δ cϕ1η 20(3.5 − 100µ )3 d
Es

Trong đó:
- δc : hệ số, đối với cấu kiện chịu uốn hoặc nén uốn δc = 1
- ϕ1 : hệ số phụ thuộc tính chất tác dụng của tải trọng, xem bản tính phía dưới
- η : hệ số, đối với cốt thép có gờ η = 1
- d: đường kính của cốt thép chịu kéo, d = 25 mm
- σs : ứng suất của thanh cốt thép chịu kéo ngoài cùng, σs = M/(As*Zb), xem bản tính
Tính toán bề rộng khe nứt (acrc) cho từng trường hợp tải trọng:

M Zb σs acrc
TH ϕ1 ν δ ϕf λ ξ
(Tm) (cm) (MPa) (mm)
Mtx 49.0 1.477 0.15 0.053 0.095 0.090 0.185 52.5 190.1 0.220
Mdh 4.6 1.477 0.15 0.005 0.095 0.090 0.204 52.1 18.1 0.021
Mnh 10.8 1 0.45 0.012 0.032 0.030 0.230 50.9 43.2 0.034
(Chú ý: ý nghĩa các thông số và phương pháp xác định xem thêm TCVN 5574-2012)

2.1. Kiểm tra điều kiện về bề rộng vết nứt ngắn hạn (toàn bộ tải trọng), a crc1

acrc1 = 0.275 mm < [acrc1] = 0.4 mm

2.2. Kiểm tra điều kiện về bề rộng vết nứt dài hạn, a crc2

acrc1 = 0.241 mm < [acrc1] = 0.3 mm

Kết luận: Cấu kiện đảm bảo điều kiện về giới hạn bề rộng vết nứt