Vibration data from a lube oil pump showed high levels of vibration. Replacing the coupling spider reduced the vibration levels as shown in the before and after comparisons in Figures 2, 3, 5, and 6, with the blue lines representing data taken after the replacement and the green lines before. Figure 1 shows vibration levels were lower after replacement compared to an earlier date, and Figure 4 compares data from before and after replacement dates.
Vibration data from a lube oil pump showed high levels of vibration. Replacing the coupling spider reduced the vibration levels as shown in the before and after comparisons in Figures 2, 3, 5, and 6, with the blue lines representing data taken after the replacement and the green lines before. Figure 1 shows vibration levels were lower after replacement compared to an earlier date, and Figure 4 compares data from before and after replacement dates.
Vibration data from a lube oil pump showed high levels of vibration. Replacing the coupling spider reduced the vibration levels as shown in the before and after comparisons in Figures 2, 3, 5, and 6, with the blue lines representing data taken after the replacement and the green lines before. Figure 1 shows vibration levels were lower after replacement compared to an earlier date, and Figure 4 compares data from before and after replacement dates.