CIVIL TECH LABS
TEST ON BM MIX GRADE - 2
Name of the Client _ [AEE, Vijayanagara Sub Division, BBMP
aaa |Asphalting of roads and improvement of drains at different
a location of New Guddadahalli in Ward No. 134,
[Agency M/s. Technical Manager-2, KRIDL
[Date of Testing [12/07/2013
[Reference MORTH Table 500-4 BM-Grade 2
‘Sample-1
18 Sieve Designation | % By Weight ‘Actual % By Weight panes
Passing IS Sieve Passing IS Sieve
100 100
90-100 97.4
56-88 82.6 ao
16-36, 34.2 senate
“19 178 Requirements
2-10 76
0-8) 68
Note:
1.The results relate only to the items tested,
2.Report shall not be reproduced except in full, without the written approval of the lab.
3.Any correction invalidates this report.
4.The results are based on the test conducted on samples supplied by the client.
CIVIL TECH LABS
#5, I Floor, ICross
Srinivasa Cotony, Mission Road
BANGALORE-580 027
Civil Tech LabsCIVIL TECH LABS
‘TEST ON BM MIX GRADE - 2
Name of the Client [ABE, Vijayanagara Sub Division, BBMP
ae /Asphalting of roads and improvement of drains at different
sa location of New Guddadahalli in Ward No. 134.
[Agency M/s. Technical Manager-2, KRIDL
[Date of Testing 12/07/2013
[Reference MORTH Table 500-4 BM-Grade 2
‘Sample-2
TS Sieve Designation | _% By Weight | Actual % By Weight svi
(mm) Passing IS Sieve | Passing IS Sieve
26.5 100) 100
19 ‘90-100 98.5
13.2 56-88 83.6
4.75 16-36 32.5 auenee)
2.36 419 174 et
0.3 2-10 84
0.075 0-8 oral
Note:
1 The results relate only to the items tested.
‘2. Report shall not be reproduced except in full, without the written approval of the lab.
3.Any correction invalidates this report.
4:The results are based on the test conducted on samples supplied by the client.
CIVIL TECH LABS
#5, 1 Floor, ICross
Srinivasa Colony, Mission Roed
BANGALORE-560 027
Civil Tech LabsCIVIL TECH LABS
Bitumen Content Determination on BM Mix-Grade 2
[Name of the Client AEE, Vijayanagara Sub Division, BBMP
[Asphaiting of roads and improvement of drains at different location of New
Name of the Work |Guddadahalli in Ward No. 134.
[Agency M/s. Technical Manager-2, KRIDL
[Date of Testing [12/07/2013
‘Specification : As Per MORTH (4th Revision) Table 500-4
Bitumen Content BM/Grade-2 is 3.3 % TO 3.5 %
SLno Description ‘Sample-1 Sample-2
T [Weight of mixture before test, @ 2000, 2000
2 Weight of mixture after test, g 1933 1934
3 Weight of bitumen extracted, ¢ 67, 66
+ Bitumen content in % 3.35 3.30
5 [Average Bitumen content in % 3.33
‘Remarks : Satisfactory
Note:
1.The results relate only to the items tested.
2.Report shalll not be reproduced except in full, without the written approval of the lab.
3.Any correction invalidates this report.
4.The results are based on the test conducted on samples supplied by the client.
CIVIL TECH LABS
#5, I Floor, ICross
Srinivasa Colony, Mission Road
BANGALORE-560 027
inchaigée
Civil Tech Labs