CIVIL TECH LABS TEST ON BM MIX GRADE - 2 Name of the Client _ [AEE, Vijayanagara Sub Division, BBMP aaa |Asphalting of roads and improvement of drains at different a location of New Guddadahalli in Ward No. 134, [Agency M/s. Technical Manager-2, KRIDL [Date of Testing [12/07/2013 [Reference MORTH Table 500-4 BM-Grade 2 ‘Sample-1 18 Sieve Designation | % By Weight ‘Actual % By Weight panes Passing IS Sieve Passing IS Sieve 100 100 90-100 97.4 56-88 82.6 ao 16-36, 34.2 senate “19 178 Requirements 2-10 76 0-8) 68 Note: 1.The results relate only to the items tested, 2.Report shall not be reproduced except in full, without the written approval of the lab. 3.Any correction invalidates this report. 4.The results are based on the test conducted on samples supplied by the client. CIVIL TECH LABS #5, I Floor, ICross Srinivasa Cotony, Mission Road BANGALORE-580 027 Civil Tech Labs CIVIL TECH LABS ‘TEST ON BM MIX GRADE - 2 Name of the Client [ABE, Vijayanagara Sub Division, BBMP ae /Asphalting of roads and improvement of drains at different sa location of New Guddadahalli in Ward No. 134. [Agency M/s. Technical Manager-2, KRIDL [Date of Testing 12/07/2013 [Reference MORTH Table 500-4 BM-Grade 2 ‘Sample-2 TS Sieve Designation | _% By Weight | Actual % By Weight svi (mm) Passing IS Sieve | Passing IS Sieve 26.5 100) 100 19 ‘90-100 98.5 13.2 56-88 83.6 4.75 16-36 32.5 auenee) 2.36 419 174 et 0.3 2-10 84 0.075 0-8 oral Note: 1 The results relate only to the items tested. ‘2. Report shall not be reproduced except in full, without the written approval of the lab. 3.Any correction invalidates this report. 4:The results are based on the test conducted on samples supplied by the client. CIVIL TECH LABS #5, 1 Floor, ICross Srinivasa Colony, Mission Roed BANGALORE-560 027 Civil Tech Labs CIVIL TECH LABS Bitumen Content Determination on BM Mix-Grade 2 [Name of the Client AEE, Vijayanagara Sub Division, BBMP [Asphaiting of roads and improvement of drains at different location of New Name of the Work |Guddadahalli in Ward No. 134. [Agency M/s. Technical Manager-2, KRIDL [Date of Testing [12/07/2013 ‘Specification : As Per MORTH (4th Revision) Table 500-4 Bitumen Content BM/Grade-2 is 3.3 % TO 3.5 % SLno Description ‘Sample-1 Sample-2 T [Weight of mixture before test, @ 2000, 2000 2 Weight of mixture after test, g 1933 1934 3 Weight of bitumen extracted, ¢ 67, 66 + Bitumen content in % 3.35 3.30 5 [Average Bitumen content in % 3.33 ‘Remarks : Satisfactory Note: 1.The results relate only to the items tested. 2.Report shalll not be reproduced except in full, without the written approval of the lab. 3.Any correction invalidates this report. 4.The results are based on the test conducted on samples supplied by the client. CIVIL TECH LABS #5, I Floor, ICross Srinivasa Colony, Mission Road BANGALORE-560 027 inchaigée Civil Tech Labs

You might also like