Professional Documents
Culture Documents
Aquadis Water Meter
Aquadis Water Meter
DN 15-20
Dimensions
Nominal diameter (DN) mm 15 20 25 30 40 60/65
B • Class C and D
Meter thread inches G 3/4" G 1" G1/4
1" G 1" 1/2 G 1" Flanges
C
mm 20x27 26x34 33x42 40x49 50x60 PN 10/16
A A mm 170* 190 260 260 300 420
• Pre-equipped for communucation
B mm 116 143 156 156 176 254
C mm 20 18 44 44 57 93 • Very low starting flow
D D mm 88 88 110 110 140 202
Weight kg 1 1.3 2.7 2.8 4.9 22.2
* Other available lengths: 105, 110, 115, 134, 165 mm (G 3/4") and 105, 165, 190 mm (G 1").
A
92,5 The Technology
The Aquadis combines the Easy Reading
advantages of piston type The Aquadis extra dry register
D technology together with combines the following
G 1’’1/2
proven reliability of the extra advantages:
74,2 dry register. No gears in Rotation close to 360° on Cyble RF fitted on the Aquadis Meter
contact with water. site
Large numbered rollers with
DN 60/65 Options (non exhaustive list) The high technology good contrast for excellent
B
implemented to manufacture reading capability
Aquadis meters may be fitted with: measuring chambers ensures
Wiper ensures readability of
stable and durable accuracy of
the extra-dry register in
Non return-valve for outlet pipe DN15, 20, 25, 30, and 40 Aquadis meter.
tough humid conditions
C
Metrological Performances Case protection: IP 68
Removable cap for DN15 and 20
A
Class C in all positions
Communication Device
Equipped with Cyble RF from the factory Class D in all positions for
Pre-equpped for future
Dn15 and coaxial
D
communication through Register for Dn15 and 20 meters
Cyble
* Both coaxial and in line, also exists variable QN 0.75 to 1 m³/h and QN1 to 1.5m³/h - **Manufacturing average values
2 Class D meter - In line DN15 and Coaxial - According to British standard 5728
Nominal flow rate Qn m3/h 1 1.5
Maximum flow rate Qmax m3/h 2 3
Minimum flow rate Qmin l/h 7.5 11.25
Coaxial Register DN 15, Class D
Transitional flow rate Qt l/h 11.5 17.25
3 Indication range m3 9 999.9999
Minimum scale interval l 0.02
Pulse Value
1
* For sizes
15 and 20 mm, 4/4 register dividesy b10 the table values.
The Aquadis is supplied pre-equipped with Key Advantages of Cyble Technology
Cyble Target Actaris standardised meter interface,
Allows communication and remote reading irrespective of meter technology and widely
Head Loss
through: spread on Actaris water meters range. bar bar
Pulse output (Cyble Sensor) Reliability brought by electronic switch (no wear 1
mm
1
m
mm
mm
mm
0.8 32 0.8
or bouncing)
40 m
m
Mbus protocol (Cyble Mbus) 25
5
15
/6
20
0.6 0.6
60
Radio frequency wireless link (Cyble RF) Reverse flow management 0.5
0.4
0.5
0.4
Principle proven in the field for more than 5 0.3 0.3 Aquadis Coaxial Model
years. 0.2
0.1
0.2
0.1
tampering m3 /h m3 /h
0 3 5 7 10 0 20 40 60