PUNCHING CHECK

COLUMN TYPE CIRCULAR


General data:
fck = 40 N/mm2
fy = 500 N/mm2
Dia of column, dia = 2000 mm
-- 1600 --
Depth of slab, d1 = 750 mm
Depth od pedestal/drop, d2 = 750 mm
total depth of critical section, d1 + d2 = 1500 mm
effective cover, d' = 75 mm
Effective depth, d = 1425 mm
width of perimeter, L22 = 3425 mm
length of perimeter, L33 = 3425 mm
perimeter, qo = pi x dia = 10759.95 mm

Load data:
Shear force, Vu = 18446.66 kN
Unbalanced moment, Mu2 = 3034.48 kNm
Unbalanced moment, Mu3 = 1287.33 kNm

Punching Shear stress calculaion:


Vu/(qo x d) = 1.203 N/mm2
Mu2/(L2 2* L33) = 0.182 N/mm2
Mu3/(L2 2* L33) = 0.077 N/mm2

Total shear stress = 1.462 N/mm2

Punching Shear capacity:


β =L2/L3 = 1.0
Ks 0.5+β = 1.5 or 1.0 whichever is less
vu Ks x 0.25√fck = 1.581 N/mm2

Demand / capacity ratio for punching = 0.92 < 1.0 Hence OK