CONTROLS
2 I TOSHIBA
LOCAL CONTROLS
There are two different types of local remote controller currently available
from Toshiba, these are:
The wired remote controller which is the standard local control device
suitable for most applications, and the wireless remote controller which
consists of a universal handset that can be purchased with a choice of
4 different wireless receiver units that are specifically designed to suit
different indoor unit model types.
TOSHIBA I 3
CONTROLS
12 I TOSHIBA
CENTRAL CONTROLS
Toshiba offer a number of different central control solutions that can be used
to control a large number of indoor units from a central location, such as a
reception area, engineering room or office space.
These control devices are connected to the air conditioner side using
Toshiba’s dedicated central control network, the TCC-Link, which can be
used to directly connect MiNi-SMMS, SHRM , and SMMS equipment.
TOSHIBA I 13
CONTROLS
24 I TOSHIBA
BUILDING MANAGEMENT
Our building management controls currently offer easy integration with the
following protocols:
Lonworks®
Modbus
BACnet®
Open ended system using digital analogue inputs & outputs
TOSHIBA I 25
What is Lonworks? What is BACnet?
Lonworks is a control system platform built on the LonTalk BACnet is a communications protocol for building automation
communications protocol created by the echelon corporation, and control networks. It is an ASHRAE, ANSI and ISO standard
and is used for the networking of equipment over media such as protocol.
twisted pair, power lines, fibre optics and radio frequency. BACnet was designed to allow communication of building
The Lonworks platform has been adopted as the basis for automation and control systems for applications such as heating,
product and service offers in many different industries including ventilation air-conditioning control, lighting control, access control,
the building industry where it is widely used for control of lighting and fire detection systems and their associated equipment. The
and HVAC systems. BACnet protocol provides mechanisms for computerized building
automation devices to exchange information, regardless of the
What is Modbus? particular building service they perform.
Modbus is a serial communications protocol that was first
published in 1979 for use with programmable logic controllers,
and has now become the most commonly available means of
connecting industrial electronic devices to a computer control
system. There are many different versions of Modbus currently
used in building management systems including Modbus RTU,
Please note that Lonworks® and BACnet® are registered trademarks,
Modbus ASCII and Modbus TCP. however these symbols have been omitted in the text.
Management level
BMS-Protocol
TOSHIBA SYSTEM
Modbus
Lonworks
BMS-Interface BACnet
Analogue/Digital I/O
BMS interface products are not compatible with each other across protocols,
only one protocol can be used per installation.
TOSHIBA I 27
CONTROLS
APPLICATION CONTROLS
Outdoor Unit PC Boards
Windows switch
TCB-IFCB5-PE Indoor All DI,SDI, VRF units
Remote on/off control
TCB-KBOS1E Peak-cut control/night operation/compressor status output Outdoor Series 4 DI, series 4 SDI excluding 1.5-1.7 PS
36 I TOSHIBA
CONTROLS
Fan output control CN32 ALL DI/SDI & VRF indoor units. Excludes RAV-SM****KRT-E, MMK-AP****MH-E
Option error input CN70 ALL DI/SDI & VRF indoor units
External error input CN80 ALL DI/SDI & VRF indoor units
40 I TOSHIBA
TCB-KBCN32VEE CN32
TCB-KBCN61HAE
CN61 - On/Off Control CN61 (Input)
Connector
The CN61 connector enables multiple input and output functions for the connected
The CN70 connector enables an external error signal to be input into the connected 1 1 Relay
indoor unit and displayed on the connected remote controller without stopping 2 2
TCB-KBCN73DEE
CN73 - Demand Input control
The CN73 connector enables an external input signal to force the connected indoor unit
into thermo off status.
Available settings: forced thermo-off control
CN80
TCB-KBCN80EXE
CN80 - External Error Input Connector
Indoor unit PC board
1 1
The CN80 connector enables an external error signal to be input into the connected 2 2
indoor unit and that will stop the indoor unit and be displayed on the connected 3 3
remote controller.
12V DC Relay
Available settings: alarm input and forced off
TOSHIBA I 41
CONTROLS
42 I TOSHIBA