= 3,14 × 1,852
= 10,75 cm2
= 0,040 cm
0,040
= × 100%
7,73
= 0,517 %
ɛ
Area corection factor =1– 100
0,517
=1– 100
= 0,995
Triaxial UU | 4
A0
Corrected Area. A' =
Area correction factor
10,75
=
0,995
= 10,803 cm2
= 28 × 0,102
= 2,856 kg
P
Deviator stress =
A'
2,856
=
10,803
= 0,264 kg/cm2
Triaxial UU | 5
HASIL UJI TRIAXIAL UU
Triaxial UU | 6
Tabel 5.1 Tabel Hasil Uji Triaxial Tegangan Keliling 0,5kg/cm2 (Lanjutan)
Vertical Dial Area Deviator
Vertical Load Regangan, Corrected Beban
Reading stress
Dial Dial ɛ Correction Area (A'), (P),
(a×kalibrasi g
Reading Reading b
(H × 100%) Factor 𝐴0 (c×LRC) ( )
vertikal) ɛ
(1- 100 ) ( 𝑒 )(cm2) f
(div) (cm) (%) (Kg) (kg/cm2)
(cm)
a b c d e f g h
Triaxial UU | 7
Tabel 5.1 Tabel Hasil Uji Triaxial Tegangan Keliling 0,5kg/cm2 (Lanjutan)
Vertical Dial Area Deviator
Vertical Load Regangan, Corrected Beban
Reading stress
Dial Dial ɛ Correction Area (A'), (P),
(a×kalibrasi g
Reading Reading (Hb × 100%) Factor 𝐴0 (c×LRC) ( )
vertikal) ɛ
(1- 100 ) ( 𝑒 )(cm2) f
(div) (cm) (%) (Kg) (kg/cm2)
(cm)
a b c d e f g h
= 0,5 + 0,988
= 1,488 kg/cm2
Triaxial UU | 8
CONTOH PERHITUNGAN UJI TRIAXIAL UU
= 3,14 × 1,852
= 10,75 cm2
= 0,040 cm
0,040
= × 100%
7,73
= 0,517 %
ɛ
Area corection factor = 1 – 100
0,517
=1– 100
= 0,995
Triaxial UU | 9
A0
Corrected Area. A' =
Area correction factor
10,75
=
0,995
= 10,803 cm2
= 32 × 0,102
= 3,264 kg
P
Deviator stress =
A'
3,264
=
10,803
= 0,302 kg/cm2
Triaxial UU | 10
HASIL UJI TRIAXIAL UU
Triaxial UU | 11
Tabel 5.2 Tabel Hasil Uji Triaxial Tegangan Keliling 1 kg/cm2 (Lanjutan)
Vertical Dial Area Deviator
Vertical Load Regangan, Corrected Beban
Reading stress
Dial Dial ɛ Correction Area (A'), (P),
(a×kalibrasi g
Reading Reading (Hb × 100%) Factor 𝐴0 (c×LRC) ( )
vertikal) ɛ
(1- 100 ) ( 𝑒 )(cm2) f
(div) (cm) (%) (Kg) (kg/cm2)
(cm)
a b c d e f g h
Triaxial UU | 12
Tabel 5.2 Tabel Hasil Uji Triaksial Teganan Keliling 1 kg/cm2 (Lanjutan)
Vertical Dial Area Deviator
Vertical Load Regangan, Corrected Beban
Reading stress
Dial Dial ɛ Correction Area (A'), (P),
(a×kalibrasi g
Reading Reading (Hb × 100%) Factor 𝐴0 (c×LRC) ( )
vertikal) ɛ
(1- 100 ) ( 𝑒 )(cm2) f
(div) (cm) (%) (Kg) (kg/cm2)
(cm)
a b c d e f g h
Triaxial UU | 13
Tegangan Deviator Maksimum (Δσ(2)) = 1,107 kg/cm2
Tegangan Utama (σ1(2)) = (σ3(2)) + (Δσ(2))
= 1 + 1,107
= 2,107 kg/cm2
Triaxial UU | 14
CONTOH PERHITUNGAN UJI TRIAXIAL UU
= 11,34 cm2
= 0,040 cm
0,040
= × 100%
7,86
= 0,509%
ɛ
Area corection factor = 1 – 100
0,509
=1– 100
= 0,995
Triaxial UU | 15
A0
Corrected Area. A' =
Area correction factor
11,34
=
0,995
= 11,393 cm2
= 29 × 0,102
= 2,958 kg
P
Deviator stress =
A'
2,958
=
11,393
= 0,260 kg/cm2
Triaxial UU | 16
HASIL UJI TRIAXIAL UU
Tabel 5.3 Tabel Hasil Uji Triaxial Tegangan Keliling 2,0 kg/cm2
Triaxial UU | 17
Tabel 5.3 Tabel Hasil Uji Triaxial Tegangan Keliling 2,0 kg/cm2 (Lanjutan)
Triaxial UU | 18
Tabel 5.3 Tabel Hasil Uji Triaxial Tegangan Keliling 2,0 kg/cm2 (Lanjutan)
Triaxial UU | 19
Tabel 5.3 Tabel Hasil Uji Triaxial Tegangan Keliling 2,0 kg/cm2 (Lanjutan)
= 2 + 1,826
= 3,826 kg/cm2
Triaxial UU | 20
GRAFIK UJI TRIAXIAL UU
1.8
1.6
Tegangan Deviator, σ (kg/cm2)
1.4
1.2
0.8
0.6
0.4
0.2
0
0.0 0.6 1.3 1.9 2.5 3.2 3.8 4.5 5.1 5.7 6.4 7.0 7.6 8.3 8.9 9.5 10.2 10.8 11.5 12.1 12.7 13.4 14.0
Regangan, ɛ (%)
Triaxial UU | 21
LINGKARAN MOHR UJI TRIAXIAL UU
Grafik 5.2 Grafik Perbandingan antara Tegangan Geser dan Tegangan Normal
2
cu = 0,15 kg/cm2 ɸ = arc tan
10
= 11,31°
Triaxial UU | 22
GAMBAR TANAH HASIL UJI TEKAN TRIAXIAL
Triaxial UU | 23
Uji 3 : Tegangan Keliling : 2,0 kg/cm2
Triaxial UU | 24
KESIMPULAN
1. Berikut adalah tabel hubungan antara consistency index dan cu sebagai berikut:
Tabel 5.4 Tabel konsistensi Tanah Menurut Nilai Kohesi
Consistency cu (kg/cm2)
Very Soft (sangat lunak) <0,125
Soft (lunak) 0,125 – 0,25
Medium Stiff (agak kaku) 0,25 – 0,5
Stiff (kaku) 0,5 – 1
Very Stiff (sangat kaku) 1– 2
Hard (keras) >2
(Sumber : http://eprints.undip.ac.id/34078/5/1924_CHAPTER_II.pdf)
Menurut Tabel 5.4 nilai cu yang diadapatkan sebesar 0,15 kg/cm2 sehingga tanah yang di
uji memiliki konsistensi soft (lunak).
2. Tabel dibawah merupakan hubungan sudut geser dengan kepadatan tanah sebagai berikut:
Tabel 5.5 Tabel Kepadatan Tanah Menurut Sudut Geser
Soil Description Class Sudut Geser
Silty sand, sand- silt mix SM 34
Clayey sand, sand- clay mix SC 31
Silt and clayey silts ML 32
Clay of low plasticity CL 28
Clayey silts, elasticsilt MH 25
Clay of hight plasticity CH 19
Lempung padat >30
Lempung lunak <19
(Sumber:http://slideshare.net/musliberjuangdotblogspotdocom/praktek-penyelidikan-tanah)
Menurut Tabel 5.5 nilai sudut geser yang diadapatkan sebesar 11,31° sehingga tanah
yang di uji memiliki klasifikasi lmpung lunak.